AED Defibrillator Rescue Sam, Progetti, Italy

AED Defibrillator Rescue Sam, Progetti, Italy

Automated External Defibrillator AED Defibrillator Rescue Sam, progetti Italy helps tackle Sudden cardiac arrest (SCA) associated with ventricular fibrillation (VF) remains a leading cause of unexpected death in the Western world. It has been estimated that chances for survival from SCA decrease approximately 7% to 10% with each passing minute and that survival rates after 12 minutes are only 2% to 5%. The most common cause of SCA is ventricular fibrillation (VF), a lethal heart
rhythm, and survival depends on the rapid treatment called defibrillation, an electrical shock sent to the heart to resume normal and healthy rhythm. So early defibrillation is the sole definitive determinant of survival and is the key factor in cardiopulmonary resuscitation. Currently, fewer than 5% of the 60.000 persons who experience out-of-hospital cardiac arrest each year survival to hospital discharge.

Specification:

AED Defibrillator Rescue Sam, Progetti, Italy

Shockable rhythms: fibrillation and/or tachycardia
Not Shockable rhythms: different from VF and VT
Waveform: BTE (biphasic truncated exponential)
Impedance: compesated
Guide Lines: AAMI DF39 2010 / AHA 2010
Shock Energy Accuracy: according to IEC EN60601-2-4
Patient Isolation: type BF
Impedance: 25 – 175 Ώ

OPERATING MODE: Semi Automatic
ENERGY: 200 j Fixed as new guidelines AHA 2010
PROTOCOL: Voice prompts and indicators guide user through protocol
CHARGE CONTROL: automatic by software
CHARGE TIME from Shock Advised: < 8 Sec, typical with new battery
CONTROLS: Shock button, info-button, On/Off Button
INDICATORS: 6 Leds and 3 scenarios
WEIGHT: 2,2 Kg with battery pack installed
SELF TEST: automatic and user activated

Optional special adapter pack for data transmission to PC via USB
– Data Stored: first 60 minutes of ECG and the entire incident’s events and
analysis decisions
– PC Software for Data Management

BATTERY
-Type: 12 Volt DC, 4,2 Ah, Lithium manganese dioxide, long life
-Model number: ELRS-002
-Capacity: min 200 shocks or 4 hours of operating time continuously
-Shelf life: typically 5 years (prior to installation)
-Standby life: typically 5 years (after installation)
-Don’t install battery packs after the expiration date the battery is not rechargeable
-Don’t immerse battery pack into the water or other liquids

Description

AED Defibrillator Rescue Sam, Progetti, Italy

Automated External Defibrillator AED Defibrillator Rescue Sam, progetti Italy helps tackle Sudden cardiac arrest (SCA) associated with ventricular fibrillation (VF) remains a leading cause of unexpected death in the Western world. It has been estimated that chances for survival from SCA decrease approximately 7% to 10% with each passing minute and that survival rates after 12 minutes are only 2% to 5%. The most common cause of SCA is ventricular fibrillation (VF), a lethal heart
rhythm, and survival depends on the rapid treatment called defibrillation, an electrical shock sent to the heart to resume normal and healthy rhythm. So early defibrillation is the sole definitive determinant of survival and is the key factor in cardiopulmonary resuscitation. Currently, fewer than 5% of the 60.000 persons who experience out-of-hospital cardiac arrest each year survival to hospital discharge.

Specification:

AED Defibrillator Rescue Sam, Progetti, Italy

Shockable rhythms: fibrillation and/or tachycardia
Not Shockable rhythms: different from VF and VT
Waveform: BTE (biphasic truncated exponential)
Impedance: compesated
Guide Lines: AAMI DF39 2010 / AHA 2010
Shock Energy Accuracy: according to IEC EN60601-2-4
Patient Isolation: type BF
Impedance: 25 – 175 Ώ

OPERATING MODE: Semi Automatic
ENERGY: 200 j Fixed as new guidelines AHA 2010
PROTOCOL: Voice prompts and indicators guide user through protocol
CHARGE CONTROL: automatic by software
CHARGE TIME from Shock Advised: < 8 Sec, typical with new battery
CONTROLS: Shock button, info-button, On/Off Button
INDICATORS: 6 Leds and 3 scenarios
WEIGHT: 2,2 Kg with battery pack installed
SELF TEST: automatic and user activated

Optional special adapter pack for data transmission to PC via USB
– Data Stored: first 60 minutes of ECG and the entire incident’s events and
analysis decisions
– PC Software for Data Management

BATTERY
-Type: 12 Volt DC, 4,2 Ah, Lithium manganese dioxide, long life
-Model number: ELRS-002
-Capacity: min 200 shocks or 4 hours of operating time continuously
-Shelf life: typically 5 years (prior to installation)
-Standby life: typically 5 years (after installation)
-Don’t install battery packs after the expiration date the battery is not rechargeable
-Don’t immerse battery pack into the water or other liquids

There are no reviews yet.