Due to surge in Dollar Rate, kindly contact us to confirm current pricing, thanks.

ICU Ventilator Lifepro 8 Plus MDX-USA

ICU Ventilator Lifepro 8 Plus MDX-USA

ICU Ventilator Lifepro 8 Plus MDX-USA are designed for the most demanding ICU environments. Built to last, the LifePro 8 ICU ventilator offers robust and consistent performance when its needed. Please click here to download the Product catalog LIFEPRO 8 PLUS.pdf 

ICU Ventilator Lifepro 8 Plus MDX-USA

Features

  • 12.1 inch TFT color screen , big screen could show more information.
  • Screen could be rotated freely, suitable to operate in any angle and height
  • With heater device to prevent water into ventilator
  • Could show Paw-t、Flow-t、Volume-t、Paw-V、Flow-V five waveform at the same time, also could show one or
  • several waveform according to our operation.
  • Curve size ,time scale, pressure-flow ratio adjustable, watch the details more good.
  • Curve pause function, could watch details.
  • Flow, pressure two trigger function, could effect at a same time.
  • Automatically inspiratory synchronous nebulizing function, nebulizing time adjustable;
  • 100% Oxygen inspiratory function, oxygen inspiratory time is adjustable.
  • High, medium, low- grade alarm function;
  • Alarm record functions, could record the last 100 pieces of information, show alarm grade, alarm time and the alarm
  • parameter.
  • Pressure, volume, time respiratory mode security, could inspect pressure in inspiratory phase, volume, time exceed the
  • regulated value, turn into expiratory, ensure patient safety.
  • Volume security function, keep the minimum tidal volume in pressure mode.
  • Adjust MMV function automatic, adjust inspiratory pressure and breathing frequency, approaching the target tidal
  • volume
  • and minute ventilator.
  • VGA connector could output the screen signal to other screen

Specification

Operating Modes

  • Volume Control Ventilation (VCV)
  • Assisted/Controlled Pressure Control Ventilation (PCV),
  • Assisted/Controlled Pressure Support Ventilation (PSV),
  • SIMV(VCV)+PSV
  • SIMV(PCV)+PSV
  • Mandatory Minute Ventilation (MMV)
  • Continuous Positive Airway Pressure(CPAP)

Parameter

  • Application scope: Pediatric and adult
  • Driven mode: pneumatically driven and electronically controlled
  • Display:12.1 TFT screen
  • Working mode: Pressure and volume
  • Ventilation wave type: squire wave, deceleration wave
  • FiO2: 21% to 100%
  • PEEP/CPAP: 0 to 40 cmH2O
  • Inspiratory Sensitivity:
  • Flow triggered: 0.5 to 20 L/min, OFF
  • Pressure triggered: -1 to -20 cmH2O, OFF
  • Tidal Volume: 20 to 2000 mL
  • Breath frequency: 1 to 100 bpm
  • I:E Ratio: 5.0 : 1 to 1 : 5.0
  • Inspiratory plateau: 0 to 50%
  • Inspiratory Flow Wave Shape(VCV): Rectangular wave and Decelerating wave
  • SIGH: 1.0 to 2.0
  • Breath frequency(SIMV): 2 to 40bpm
  • Inspiratory time (SIMV): 0.1 to 12 S
  • Pressure Support Ventilation (PSV): 0 to 40 cmH2O
  • Expiratory Sensitivity for PSV : 10% to 75% of the initial flow
  • Maximum Inspiratory time (PSV): 1.0 to 8.0 S
  • Pressure Control Ventilation(PCV): 0 to 40 cmH2O
  • Minimum Tidal Volume(PCV and PSV): 50 to 1500 mL
  • Backup Rate (PSV): 2 to 40 bpm
  • Object Tidal Volume(MMV): 20 to 2000 mL
  • Ventilation volume(MMV): 0.5 to 40.0 L/min
  • Nebulizer time: 30 minutes

Monitoring

  • Breathing wave: Pressure vs time curve,Flow vs time curve,Volume vs time curve,Pressure vs volume loops,Flow vs volume loops
  • Expiratory tidal volume:,
  • Breath frequency(bpm),
  • PEEP:
  • FiO2
  • MV
  • Insipiratory Tidal volume(TV_Insp):
  • I:E ratio:
  • Freq_indepen:
  • MV_Indepen:
  • Pmean
  • Pflat:,
  • Airway Pressure
  • Ppeak,
  • Minute Ventilation,
  • Oxygen concentration

Alarms

  • High tidal volume alarm
  • Low tidal volume alarm
  • High minute ventilation alarm
  • Low minute ventilation alarm
  • High breathing frequency alarm
  • Low breathing frequency alarm
  • High peak pressure alarm
  • Low peak pressure alarm
  • High PEEP pressure alarm
  • Low PEEP pressure alarm
  • High oxygen concentration alarm
  • Low oxygen concentration alarm
  • Apnea time alarm
  • Respirtory arrest alarm
  • AC power fail alarm
  • Air source Low pressure alarm
  • Oxygen source low pressure alarm
  • Batterydisconnect alarm
  • Low battery alarm
  • Circle leakage alarm
  • Circle block alarm

Air compressor BC100 (Optional)

Feature:

  • Low noise medical air Compressor, very stable performance, safe and reliable,
  • Air Compressor with LCD screen to display output pressure, provide safe, secure and permanent motivation
  • Compact design and easy to transfer
  • Assembled with clean control module, supplying cleaner and safer air to the patients
  • Effective sound-absorbing materials
  • Match with various ventilator of international standard in the world

Specification

NO. Name Specifications Notes
1 Output gas flow ≥40L/min
2 Output gas pressure 0.3~0.4Mpa Adjustable
3 Output gas filter accuracy 0.03μm
4 Air compressor pump 1sets
5 Efficient rate for particle filtration 99%
6 Dew point of output gas: 0~10℃ Dried output gas
7 Noise 46~48dB(A)
8 Power supply 220V±15% ,50HZ or 110V±15%,60HZ
9 Power <800W
10 Working Environment Temperature 0~40°C

Humidity<90RH

11 Net Weight

40kg

12 Size

510*560*610mm

POWER REQUIREMENT

Main power: from 85 to 265VAC 47-63HZ

Automatic voltage switch

Internal battery: 12VDC; 7AH

Automatic recharge.

Estimated duration: more than 2 hours when completely charged.

The display shows an icon with the charge level.

PNEUMATIC REQUIREMENT

Oxygen: pressure 2.8 to 6 bar ISO5359 connector

Air: pressure 2.8 to 6 bar ISO 5359 connector

Description

ICU Ventilator Lifepro 8 Plus MDX-USA

ICU Ventilator Lifepro 8 Plus MDX-USA are designed for the most demanding ICU environments. Built to last, the LifePro 8 ICU ventilator offers robust and consistent performance when its needed. Please click here to download the Product catalog LIFEPRO 8 PLUS.pdf 

ICU Ventilator Lifepro 8 Plus MDX-USA

Features

  • 12.1 inch TFT color screen , big screen could show more information.
  • Screen could be rotated freely, suitable to operate in any angle and height
  • With heater device to prevent water into ventilator
  • Could show Paw-t、Flow-t、Volume-t、Paw-V、Flow-V five waveform at the same time, also could show one or
  • several waveform according to our operation.
  • Curve size ,time scale, pressure-flow ratio adjustable, watch the details more good.
  • Curve pause function, could watch details.
  • Flow, pressure two trigger function, could effect at a same time.
  • Automatically inspiratory synchronous nebulizing function, nebulizing time adjustable;
  • 100% Oxygen inspiratory function, oxygen inspiratory time is adjustable.
  • High, medium, low- grade alarm function;
  • Alarm record functions, could record the last 100 pieces of information, show alarm grade, alarm time and the alarm
  • parameter.
  • Pressure, volume, time respiratory mode security, could inspect pressure in inspiratory phase, volume, time exceed the
  • regulated value, turn into expiratory, ensure patient safety.
  • Volume security function, keep the minimum tidal volume in pressure mode.
  • Adjust MMV function automatic, adjust inspiratory pressure and breathing frequency, approaching the target tidal
  • volume
  • and minute ventilator.
  • VGA connector could output the screen signal to other screen

Specification

Operating Modes

  • Volume Control Ventilation (VCV)
  • Assisted/Controlled Pressure Control Ventilation (PCV),
  • Assisted/Controlled Pressure Support Ventilation (PSV),
  • SIMV(VCV)+PSV
  • SIMV(PCV)+PSV
  • Mandatory Minute Ventilation (MMV)
  • Continuous Positive Airway Pressure(CPAP)

Parameter

  • Application scope: Pediatric and adult
  • Driven mode: pneumatically driven and electronically controlled
  • Display:12.1 TFT screen
  • Working mode: Pressure and volume
  • Ventilation wave type: squire wave, deceleration wave
  • FiO2: 21% to 100%
  • PEEP/CPAP: 0 to 40 cmH2O
  • Inspiratory Sensitivity:
  • Flow triggered: 0.5 to 20 L/min, OFF
  • Pressure triggered: -1 to -20 cmH2O, OFF
  • Tidal Volume: 20 to 2000 mL
  • Breath frequency: 1 to 100 bpm
  • I:E Ratio: 5.0 : 1 to 1 : 5.0
  • Inspiratory plateau: 0 to 50%
  • Inspiratory Flow Wave Shape(VCV): Rectangular wave and Decelerating wave
  • SIGH: 1.0 to 2.0
  • Breath frequency(SIMV): 2 to 40bpm
  • Inspiratory time (SIMV): 0.1 to 12 S
  • Pressure Support Ventilation (PSV): 0 to 40 cmH2O
  • Expiratory Sensitivity for PSV : 10% to 75% of the initial flow
  • Maximum Inspiratory time (PSV): 1.0 to 8.0 S
  • Pressure Control Ventilation(PCV): 0 to 40 cmH2O
  • Minimum Tidal Volume(PCV and PSV): 50 to 1500 mL
  • Backup Rate (PSV): 2 to 40 bpm
  • Object Tidal Volume(MMV): 20 to 2000 mL
  • Ventilation volume(MMV): 0.5 to 40.0 L/min
  • Nebulizer time: 30 minutes

Monitoring

  • Breathing wave: Pressure vs time curve,Flow vs time curve,Volume vs time curve,Pressure vs volume loops,Flow vs volume loops
  • Expiratory tidal volume:,
  • Breath frequency(bpm),
  • PEEP:
  • FiO2
  • MV
  • Insipiratory Tidal volume(TV_Insp):
  • I:E ratio:
  • Freq_indepen:
  • MV_Indepen:
  • Pmean
  • Pflat:,
  • Airway Pressure
  • Ppeak,
  • Minute Ventilation,
  • Oxygen concentration

Alarms

  • High tidal volume alarm
  • Low tidal volume alarm
  • High minute ventilation alarm
  • Low minute ventilation alarm
  • High breathing frequency alarm
  • Low breathing frequency alarm
  • High peak pressure alarm
  • Low peak pressure alarm
  • High PEEP pressure alarm
  • Low PEEP pressure alarm
  • High oxygen concentration alarm
  • Low oxygen concentration alarm
  • Apnea time alarm
  • Respirtory arrest alarm
  • AC power fail alarm
  • Air source Low pressure alarm
  • Oxygen source low pressure alarm
  • Batterydisconnect alarm
  • Low battery alarm
  • Circle leakage alarm
  • Circle block alarm

Air compressor BC100 (Optional)

Feature:

  • Low noise medical air Compressor, very stable performance, safe and reliable,
  • Air Compressor with LCD screen to display output pressure, provide safe, secure and permanent motivation
  • Compact design and easy to transfer
  • Assembled with clean control module, supplying cleaner and safer air to the patients
  • Effective sound-absorbing materials
  • Match with various ventilator of international standard in the world

Specification

NO. Name Specifications Notes
1 Output gas flow ≥40L/min
2 Output gas pressure 0.3~0.4Mpa Adjustable
3 Output gas filter accuracy 0.03μm
4 Air compressor pump 1sets
5 Efficient rate for particle filtration 99%
6 Dew point of output gas: 0~10℃ Dried output gas
7 Noise 46~48dB(A)
8 Power supply 220V±15% ,50HZ or 110V±15%,60HZ
9 Power <800W
10 Working Environment Temperature 0~40°C

Humidity<90RH

11 Net Weight

40kg

12 Size

510*560*610mm

POWER REQUIREMENT

Main power: from 85 to 265VAC 47-63HZ

Automatic voltage switch

Internal battery: 12VDC; 7AH

Automatic recharge.

Estimated duration: more than 2 hours when completely charged.

The display shows an icon with the charge level.

PNEUMATIC REQUIREMENT

Oxygen: pressure 2.8 to 6 bar ISO5359 connector

Air: pressure 2.8 to 6 bar ISO 5359 connector

There are no reviews yet.

Add your review