Description
ICU Ventilator Lifepro 8 Plus MDX-USA
ICU Ventilator Lifepro 8 Plus MDX-USA are designed for the most demanding ICU environments. Built to last, the LifePro 8 ICU ventilator offers robust and consistent performance when its needed. Please click here to download the Product catalog LIFEPRO 8 PLUS.pdf
ICU Ventilator Lifepro 8 Plus MDX-USA
Features
- 12.1 inch TFT color screen , big screen could show more information.
- Screen could be rotated freely, suitable to operate in any angle and height
- With heater device to prevent water into ventilator
- Could show Paw-t、Flow-t、Volume-t、Paw-V、Flow-V five waveform at the same time, also could show one or
- several waveform according to our operation.
- Curve size ,time scale, pressure-flow ratio adjustable, watch the details more good.
- Curve pause function, could watch details.
- Flow, pressure two trigger function, could effect at a same time.
- Automatically inspiratory synchronous nebulizing function, nebulizing time adjustable;
- 100% Oxygen inspiratory function, oxygen inspiratory time is adjustable.
- High, medium, low- grade alarm function;
- Alarm record functions, could record the last 100 pieces of information, show alarm grade, alarm time and the alarm
- parameter.
- Pressure, volume, time respiratory mode security, could inspect pressure in inspiratory phase, volume, time exceed the
- regulated value, turn into expiratory, ensure patient safety.
- Volume security function, keep the minimum tidal volume in pressure mode.
- Adjust MMV function automatic, adjust inspiratory pressure and breathing frequency, approaching the target tidal
- volume
- and minute ventilator.
- VGA connector could output the screen signal to other screen
Specification
Operating Modes
- Volume Control Ventilation (VCV)
- Assisted/Controlled Pressure Control Ventilation (PCV),
- Assisted/Controlled Pressure Support Ventilation (PSV),
- SIMV(VCV)+PSV
- SIMV(PCV)+PSV
- Mandatory Minute Ventilation (MMV)
- Continuous Positive Airway Pressure(CPAP)
Parameter
- Application scope: Pediatric and adult
- Driven mode: pneumatically driven and electronically controlled
- Display:12.1 TFT screen
- Working mode: Pressure and volume
- Ventilation wave type: squire wave, deceleration wave
- FiO2: 21% to 100%
- PEEP/CPAP: 0 to 40 cmH2O
- Inspiratory Sensitivity:
- Flow triggered: 0.5 to 20 L/min, OFF
- Pressure triggered: -1 to -20 cmH2O, OFF
- Tidal Volume: 20 to 2000 mL
- Breath frequency: 1 to 100 bpm
- I:E Ratio: 5.0 : 1 to 1 : 5.0
- Inspiratory plateau: 0 to 50%
- Inspiratory Flow Wave Shape(VCV): Rectangular wave and Decelerating wave
- SIGH: 1.0 to 2.0
- Breath frequency(SIMV): 2 to 40bpm
- Inspiratory time (SIMV): 0.1 to 12 S
- Pressure Support Ventilation (PSV): 0 to 40 cmH2O
- Expiratory Sensitivity for PSV : 10% to 75% of the initial flow
- Maximum Inspiratory time (PSV): 1.0 to 8.0 S
- Pressure Control Ventilation(PCV): 0 to 40 cmH2O
- Minimum Tidal Volume(PCV and PSV): 50 to 1500 mL
- Backup Rate (PSV): 2 to 40 bpm
- Object Tidal Volume(MMV): 20 to 2000 mL
- Ventilation volume(MMV): 0.5 to 40.0 L/min
- Nebulizer time: 30 minutes
Monitoring
- Breathing wave: Pressure vs time curve,Flow vs time curve,Volume vs time curve,Pressure vs volume loops,Flow vs volume loops
- Expiratory tidal volume:,
- Breath frequency(bpm),
- PEEP:
- FiO2
- MV
- Insipiratory Tidal volume(TV_Insp):
- I:E ratio:
- Freq_indepen:
- MV_Indepen:
- Pmean
- Pflat:,
- Airway Pressure
- Ppeak,
- Minute Ventilation,
- Oxygen concentration
Alarms
- High tidal volume alarm
- Low tidal volume alarm
- High minute ventilation alarm
- Low minute ventilation alarm
- High breathing frequency alarm
- Low breathing frequency alarm
- High peak pressure alarm
- Low peak pressure alarm
- High PEEP pressure alarm
- Low PEEP pressure alarm
- High oxygen concentration alarm
- Low oxygen concentration alarm
- Apnea time alarm
- Respirtory arrest alarm
- AC power fail alarm
- Air source Low pressure alarm
- Oxygen source low pressure alarm
- Batterydisconnect alarm
- Low battery alarm
- Circle leakage alarm
- Circle block alarm
Air compressor BC100 (Optional)
Feature:
- Low noise medical air Compressor, very stable performance, safe and reliable,
- Air Compressor with LCD screen to display output pressure, provide safe, secure and permanent motivation
- Compact design and easy to transfer
- Assembled with clean control module, supplying cleaner and safer air to the patients
- Effective sound-absorbing materials
- Match with various ventilator of international standard in the world
Specification
NO. | Name | Specifications | Notes |
1 | Output gas flow | ≥40L/min | |
2 | Output gas pressure | 0.3~0.4Mpa | Adjustable |
3 | Output gas filter accuracy | 0.03μm | |
4 | Air compressor pump | 1sets | |
5 | Efficient rate for particle filtration | 99% | |
6 | Dew point of output gas: | 0~10℃ | Dried output gas |
7 | Noise | 46~48dB(A) | |
8 | Power supply | 220V±15% ,50HZ or 110V±15%,60HZ | |
9 | Power | <800W | |
10 | Working Environment | Temperature 0~40°C
Humidity<90RH |
|
11 | Net Weight |
40kg |
|
12 | Size |
510*560*610mm |
|
POWER REQUIREMENT
Main power: from 85 to 265VAC 47-63HZ
Automatic voltage switch
Internal battery: 12VDC; 7AH
Automatic recharge.
Estimated duration: more than 2 hours when completely charged.
The display shows an icon with the charge level.
PNEUMATIC REQUIREMENT
Oxygen: pressure 2.8 to 6 bar ISO5359 connector
Air: pressure 2.8 to 6 bar ISO 5359 connector