Search Results for: patient monitor
ICU Ventilator Lifepro 8 Plus MDX-USA
ICU Ventilator Lifepro 8 Plus MDX-USA
ICU Ventilator Lifepro 8 Plus MDX-USA are designed for the most demanding ICU environments. Built to last, the LifePro 8 ICU ventilator offers robust and consistent performance when its needed. Please click here to download the Product catalog LIFEPRO 8 PLUS.pdf ICU Ventilator Lifepro 8 Plus MDX-USA Features- 12.1 inch TFT color screen , big screen could show more information.
- Screen could be rotated freely, suitable to operate in any angle and height
- With heater device to prevent water into ventilator
- Could show Paw-t、Flow-t、Volume-t、Paw-V、Flow-V five waveform at the same time, also could show one or
- several waveform according to our operation.
- Curve size ,time scale, pressure-flow ratio adjustable, watch the details more good.
- Curve pause function, could watch details.
- Flow, pressure two trigger function, could effect at a same time.
- Automatically inspiratory synchronous nebulizing function, nebulizing time adjustable;
- 100% Oxygen inspiratory function, oxygen inspiratory time is adjustable.
- High, medium, low- grade alarm function;
- Alarm record functions, could record the last 100 pieces of information, show alarm grade, alarm time and the alarm
- parameter.
- Pressure, volume, time respiratory mode security, could inspect pressure in inspiratory phase, volume, time exceed the
- regulated value, turn into expiratory, ensure patient safety.
- Volume security function, keep the minimum tidal volume in pressure mode.
- Adjust MMV function automatic, adjust inspiratory pressure and breathing frequency, approaching the target tidal
- volume
- and minute ventilator.
- VGA connector could output the screen signal to other screen
- Volume Control Ventilation (VCV)
- Assisted/Controlled Pressure Control Ventilation (PCV),
- Assisted/Controlled Pressure Support Ventilation (PSV),
- SIMV(VCV)+PSV
- SIMV(PCV)+PSV
- Mandatory Minute Ventilation (MMV)
- Continuous Positive Airway Pressure(CPAP)
- Application scope: Pediatric and adult
- Driven mode: pneumatically driven and electronically controlled
- Display:12.1 TFT screen
- Working mode: Pressure and volume
- Ventilation wave type: squire wave, deceleration wave
- FiO2: 21% to 100%
- PEEP/CPAP: 0 to 40 cmH2O
- Inspiratory Sensitivity:
- Flow triggered: 0.5 to 20 L/min, OFF
- Pressure triggered: -1 to -20 cmH2O, OFF
- Tidal Volume: 20 to 2000 mL
- Breath frequency: 1 to 100 bpm
- I:E Ratio: 5.0 : 1 to 1 : 5.0
- Inspiratory plateau: 0 to 50%
- Inspiratory Flow Wave Shape(VCV): Rectangular wave and Decelerating wave
- SIGH: 1.0 to 2.0
- Breath frequency(SIMV): 2 to 40bpm
- Inspiratory time (SIMV): 0.1 to 12 S
- Pressure Support Ventilation (PSV): 0 to 40 cmH2O
- Expiratory Sensitivity for PSV : 10% to 75% of the initial flow
- Maximum Inspiratory time (PSV): 1.0 to 8.0 S
- Pressure Control Ventilation(PCV): 0 to 40 cmH2O
- Minimum Tidal Volume(PCV and PSV): 50 to 1500 mL
- Backup Rate (PSV): 2 to 40 bpm
- Object Tidal Volume(MMV): 20 to 2000 mL
- Ventilation volume(MMV): 0.5 to 40.0 L/min
- Nebulizer time: 30 minutes
- Breathing wave: Pressure vs time curve,Flow vs time curve,Volume vs time curve,Pressure vs volume loops,Flow vs volume loops
- Expiratory tidal volume:,
- Breath frequency(bpm),
- PEEP:
- FiO2
- MV
- Insipiratory Tidal volume(TV_Insp):
- I:E ratio:
- Freq_indepen:
- MV_Indepen:
- Pmean
- Pflat:,
- Airway Pressure
- Ppeak,
- Minute Ventilation,
- Oxygen concentration
- High tidal volume alarm
- Low tidal volume alarm
- High minute ventilation alarm
- Low minute ventilation alarm
- High breathing frequency alarm
- Low breathing frequency alarm
- High peak pressure alarm
- Low peak pressure alarm
- High PEEP pressure alarm
- Low PEEP pressure alarm
- High oxygen concentration alarm
- Low oxygen concentration alarm
- Apnea time alarm
- Respirtory arrest alarm
- AC power fail alarm
- Air source Low pressure alarm
- Oxygen source low pressure alarm
- Batterydisconnect alarm
- Low battery alarm
- Circle leakage alarm
- Circle block alarm
- Low noise medical air Compressor, very stable performance, safe and reliable,
- Air Compressor with LCD screen to display output pressure, provide safe, secure and permanent motivation
- Compact design and easy to transfer
- Assembled with clean control module, supplying cleaner and safer air to the patients
- Effective sound-absorbing materials
- Match with various ventilator of international standard in the world
| NO. | Name | Specifications | Notes |
| 1 | Output gas flow | ≥40L/min | |
| 2 | Output gas pressure | 0.3~0.4Mpa | Adjustable |
| 3 | Output gas filter accuracy | 0.03μm | |
| 4 | Air compressor pump | 1sets | |
| 5 | Efficient rate for particle filtration | 99% | |
| 6 | Dew point of output gas: | 0~10℃ | Dried output gas |
| 7 | Noise | 46~48dB(A) | |
| 8 | Power supply | 220V±15% ,50HZ or 110V±15%,60HZ | |
| 9 | Power | <800W | |
| 10 | Working Environment | Temperature 0~40°C Humidity<90RH | |
| 11 | Net Weight |
40kg |
|
| 12 | Size |
510*560*610mm |
ICU Ventilator Lifepro 8 MDX-USA
ICU Ventilator Lifepro 8 MDX-USA
ICU Ventilator Lifepro 8 MDX-USA are designed for the most demanding ICU environments. Built to last, the LifePro 8 ICU ventilator offers robust and consistent performance when its needed. Click the link to download complete catalog LifePro™ 8 ICU VENT.pdfICU Ventilator Lifepro 8 MDX-USA
Features- 12.1 inch TFT color screen , big screen could show more information.
- Screen could be rotated freely, suitable to operate in any angle and height
- With heater device to prevent water into ventilator
- Could show Paw-t、Flow-t、Volume-t、Paw-V、Flow-V five waveform at the same time, also could show one or
- several waveform according to our operation.
- Curve size ,time scale, pressure-flow ratio adjustable, watch the details more good.
- Curve pause function, could watch details.
- Flow, pressure two trigger function, could effect at a same time.
- Automatically inspiratory synchronous nebulizing function, nebulizing time adjustable;
- 100% Oxygen inspiratory function, oxygen inspiratory time is adjustable.
- High, medium, low- grade alarm function;
- Alarm record functions, could record the last 100 pieces of information, show alarm grade, alarm time and the alarm
- parameter.
- Pressure, volume, time respiratory mode security, could inspect pressure in inspiratory phase, volume, time exceed the
- regulated value, turn into expiratory, ensure patient safety.
- Volume security function, keep the minimum tidal volume in pressure mode.
- Adjust MMV function automatic, adjust inspiratory pressure and breathing frequency, approaching the target tidal
- volume
- and minute ventilator.
- VGA connector could output the screen signal to other screen
- Specification
- Volume Control Ventilation (VCV)
- Assisted/Controlled Pressure Control Ventilation (PCV),
- Assisted/Controlled Pressure Support Ventilation (PSV),
- SIMV(VCV)+PSV
- SIMV(PCV)+PSV
- Mandatory Minute Ventilation (MMV)
- Continuous Positive Airway Pressure(CPAP)
- Application scope: Pediatric and adult
- Driven mode: pneumatically driven and electronically controlled
- Display:12.1 TFT screen
- Working mode: Pressure and volume
- Ventilation wave type: squire wave, deceleration wave
- FiO2: 21% to 100%
- PEEP/CPAP: 0 to 40 cmH2O
- Inspiratory Sensitivity:
- Flow triggered: 0.5 to 20 L/min, OFF
- Pressure triggered: -1 to -20 cmH2O, OFF
- Tidal Volume: 20 to 2000 mL
- Breath frequency: 1 to 100 bpm
- I:E Ratio: 5.0 : 1 to 1 : 5.0
- Inspiratory plateau: 0 to 50%
- Inspiratory Flow Wave Shape(VCV): Rectangular wave and Decelerating wave
- SIGH: 1.0 to 2.0
- Breath frequency(SIMV): 2 to 40bpm
- Inspiratory time (SIMV): 0.1 to 12 S
- Pressure Support Ventilation (PSV): 0 to 40 cmH2O
- Expiratory Sensitivity for PSV : 10% to 75% of the initial flow
- Maximum Inspiratory time (PSV): 1.0 to 8.0 S
- Pressure Control Ventilation(PCV): 0 to 40 cmH2O
- Minimum Tidal Volume(PCV and PSV): 50 to 1500 mL
- Backup Rate (PSV): 2 to 40 bpm
- Object Tidal Volume(MMV): 20 to 2000 mL
- Ventilation volume(MMV): 0.5 to 40.0 L/min
- Nebulizer time: 30 minutes
- Breathing wave: Pressure vs time curve,Flow vs time curve,Volume vs time curve,Pressure vs volume loops,Flow vs volume loops
- Expiratory tidal volume:,
- Breath frequency(bpm),
- PEEP:
- FiO2
- MV
- Insipiratory Tidal volume(TV_Insp):
- I:E ratio:
- Freq_indepen:
- MV_Indepen:
- Pmean
- Pflat:,
- Airway Pressure
- Ppeak,
- Minute Ventilation,
- Oxygen concentration
- High tidal volume alarm
- Low tidal volume alarm
- High minute ventilation alarm
- Low minute ventilation alarm
- High breathing frequency alarm
- Low breathing frequency alarm
- High peak pressure alarm
- Low peak pressure alarm
- High PEEP pressure alarm
- Low PEEP pressure alarm
- High oxygen concentration alarm
- Low oxygen concentration alarm
- Apnea time alarm
- Respirtory arrest alarm
- AC power fail alarm
- Air source Low pressure alarm
- Oxygen source low pressure alarm
- Batterydisconnect alarm
- Low battery alarm
- Circle leakage alarm
- Circle block alarm
| NO. | Name | Specifications | Notes |
| 1 | Output gas flow | ≥40L/min | |
| 2 | Output gas pressure | 0.3~0.4Mpa | Adjustable |
| 3 | Output gas filter accuracy | 0.03μm | |
| 4 | Air compressor pump | 1sets | |
| 5 | Efficient rate for particle filtration | 99% | |
| 6 | Dew point of output gas: | 0~10℃ | Dried output gas |
| 7 | Noise | 46~48dB(A) | |
| 8 | Power supply | 220V±15% ,50HZ or 110V±15%,60HZ | |
| 9 | Power | <800W | |
| 10 | Working Environment | Temperature 0~40°C Humidity<90RH | |
| 11 | Net Weight |
40kg |
|
| 12 | Size |
510*560*610mm |
Defibrillator Rescue life
Defibrillator Rescue life
Defibrillator Rescue life is Designed to be the ideal device to deal with cardiovascular emergencies and to monitor the patient in hospital and non-hospital environments. Thanks to its compact and shockproof design. RESCUE LIFE is the best ally for hard times. When time becomes an enemy, thanks to its intuitive navigation interface RESCUE LIFE lets the user initiate its functions in a fast and easy way. Developed with the purpose to satisfy the most elevated demands, RESCUE LIFE guarantees a complete monitoring of the patient in a critical situation: blood pressure, saturation and 12-leads ECG allow the user to have a clear picture of the clinical situation. With its state-of-the-art biphasic technology, RESCUE LIFE guarantees the maximum effectiveness in the shortest time. RESCUE LIFE means versatility. TECHNICAL SPECIFICATIONS GENERAL SPECIFICATIONS Dimension • 369 x 240 x 340 mm Weight • 5,5 Kg with battery Electrical •• AC 100-240 VAC, 50/60 Hz- inverter12V car adapter (optional) Rechargeable 14.4 V - 2 Ah NiMh battery Capacity • 100 shocks at 230J with battery fully charged Software • Voice and texts multilanguage Memory • Internal flash 4 Gb up to 300 hrs of ECG data, events and usage review ENVIRONMENTAL Temperature ••• Operational -5° ~ 55° C Storage -20° ~ 70° C Relative humidity 10 ~ 95% Isolation • ECG type CF, Defibrillation type BF Water proof • Class IPX4 DEFIBRILLATION Waveform •• Bipashic Truncated Exponential (BTE) HiCAP technology (Large storage capacitor) Impedance • Compensated, range 25 - 200 Ohm Charge time • 6 sec for 230 J with battery fully charged AED MODE (OPTIONAL) Energy • Fixed energy at 200 J Protocol • AHA 2010 CPR Guidelines with voice and text prompts Shockable rhythms • VF with amplitude > 100 μV and VT with rhythm >150 bpm Sensitivity •• Shockable rhythm-VF > 95% Shockable rhythm-VT > 75% Specificity ••• According to AHA 2010 Normal sinusoidal rhythm > 99% Asystole and other non-shockable rhythms > 95% MANUAL MODE Energy range • 1 - 230 J (from 1-10 J in 1 J steps; from 10 to 230 J in 10 J steps) Commands • Multifunction trim knob. Charge and shock button directly in the front panel for hands free defibrillation Paddles •• Reusable adult & pediatric defi paddles with charge/shock command Disposable defi pads and internal defi paddles (optional) Operating mode • ECG « R » wave synchro or asynchro mode Indicators •• Battery and main led indicators Clear and visible backlight color buttons DISPLAY Type • High contrast TFT color LCD 5.7” (320 x 240 pixels) Information • Operational information, ECG traces, Spo2 value, NIBP values, parameters, Heart Rate indicator, filters, alarms and battery status ECG MONITORING Bandwidth • 0.5 - 120 Hz (-3 db) with filters off CMRR • > 90 db Input impedance • > 20 Mohm Input •• Patient cable 5 leads (I,II,III,aVL,aVR,aVF) - standard Patient cable 10 leads (12 channels ECG) - optional Gain • 5, 10, 20 mm/mV with patient cable. AUTO with pads Velocity • 5, 10, 25, 50 mm/sec Filters • 50/60 Hz, EMG Filter, base line HR range • 20 - 300 bpm (~ 2%), digital readout on the display Alarm • HR max settable 250 bpm; HR min 20 bpm SPO2 (OPTIONAL) SpO2 range • 0 - 100% HR range • 18 - 300 ppm Accuracy • 70 - 100% ~ 2% for adults with finger clip sensor Alarm • Adjustable min 65% PRINTER Type • Integrated thermal printer for ECG traces and events documentation hardcopy including HR/SpO2/NIBP values Paper speed • 5, 10, 25, 50 mm/sec Paper width • 58 mm Operating model • Manual, automatic (10” pre and post shock recording) EXTERNAL PACEMAKER (OPTIONAL) Type • Rettangular wave Operating mode • Fixed on demand Pulse rate • 30 ppm to 250 ppm, adjustable in steps of 5 ppm Impulse duration • 22 ms Pulse current • 0 to 150 mA adjustable in steps of 5mA Amplitude • Max 150 V STANDARDS & SAFETY Standard • IEC 60601-2-4; IEC 60601-1; IEC 60601-1-2, Class II, type BF CE Mark EEC 93/42 • Medical device, class IIb Specifications and contents of this document subject to change without notice.Mindray EATO EX-20 Anesthesia Machine
Mindray WATO EX-20 Anesthesia Workstation (often referred to simply as the EX-20) is designed to provide stable, reliable performance for routine anesthesia procedures, accommodating patients from pediatrics to adults.
Features:
- Stability: High-quality components and technology ensure reliable operation.
- Dynamic gas compensation for precise tidal volumes and a patented three-flow sensor design for more accurate monitoring and an extended sensor lifespan.
- Completeness: It is equipped with comprehensive standard configurations to meet daily clinical needs.
- Simplicity: The design aims to simplify training and operation for clinicians.