AED Defibrillator Rescue Sam, Progetti, Italy
AED Defibrillator Rescue Sam, Progetti, Italy
Automated External Defibrillator AED Defibrillator Rescue Sam, progetti Italy helps tackle Sudden cardiac arrest (SCA) associated with ventricular fibrillation (VF) remains a leading cause of unexpected death in the Western world. It has been estimated that chances for survival from SCA decrease approximately 7% to 10% with each passing minute and that survival rates after 12 minutes are only 2% to 5%. The most common cause of SCA is ventricular fibrillation (VF), a lethal heart
rhythm, and survival depends on the rapid treatment called defibrillation, an electrical shock sent to the heart to resume normal and healthy rhythm. So early defibrillation is the sole definitive determinant of survival and is the key factor in cardiopulmonary resuscitation. Currently, fewer than 5% of the 60.000 persons who experience out-of-hospital cardiac arrest each year survival to hospital discharge.
Specification:
AED Defibrillator Rescue Sam, Progetti, Italy
Shockable rhythms: fibrillation and/or tachycardia
Not Shockable rhythms: different from VF and VT
Waveform: BTE (biphasic truncated exponential)
Impedance: compesated
Guide Lines: AAMI DF39 2010 / AHA 2010
Shock Energy Accuracy: according to IEC EN60601-2-4
Patient Isolation: type BF
Impedance: 25 – 175 Ώ
OPERATING MODE: Semi Automatic
ENERGY: 200 j Fixed as new guidelines AHA 2010
PROTOCOL: Voice prompts and indicators guide user through protocol
CHARGE CONTROL: automatic by software
CHARGE TIME from Shock Advised: < 8 Sec, typical with new battery
CONTROLS: Shock button, info-button, On/Off Button
INDICATORS: 6 Leds and 3 scenarios
WEIGHT: 2,2 Kg with battery pack installed
SELF TEST: automatic and user activated
Optional special adapter pack for data transmission to PC via USB
– Data Stored: first 60 minutes of ECG and the entire incident’s events and
analysis decisions
– PC Software for Data Management
BATTERY
-Type: 12 Volt DC, 4,2 Ah, Lithium manganese dioxide, long life
-Model number: ELRS-002
-Capacity: min 200 shocks or 4 hours of operating time continuously
-Shelf life: typically 5 years (prior to installation)
-Standby life: typically 5 years (after installation)
-Don’t install battery packs after the expiration date the battery is not rechargeable
-Don’t immerse battery pack into the water or other liquids
AED Defibrillator Rescue Sam, Progetti, Italy
Automated External Defibrillator AED Defibrillator Rescue Sam, progetti Italy helps tackle Sudden cardiac arrest (SCA) associated with ventricular fibrillation (VF) remains a leading cause of unexpected death in the Western world. It has been estimated that chances for survival from SCA decrease approximately 7% to 10% with each passing minute and that survival rates after 12 minutes are only 2% to 5%. The most common cause of SCA is ventricular fibrillation (VF), a lethal heart
rhythm, and survival depends on the rapid treatment called defibrillation, an electrical shock sent to the heart to resume normal and healthy rhythm. So early defibrillation is the sole definitive determinant of survival and is the key factor in cardiopulmonary resuscitation. Currently, fewer than 5% of the 60.000 persons who experience out-of-hospital cardiac arrest each year survival to hospital discharge.
Specification:
AED Defibrillator Rescue Sam, Progetti, Italy
Shockable rhythms: fibrillation and/or tachycardia
Not Shockable rhythms: different from VF and VT
Waveform: BTE (biphasic truncated exponential)
Impedance: compesated
Guide Lines: AAMI DF39 2010 / AHA 2010
Shock Energy Accuracy: according to IEC EN60601-2-4
Patient Isolation: type BF
Impedance: 25 – 175 Ώ
OPERATING MODE: Semi Automatic
ENERGY: 200 j Fixed as new guidelines AHA 2010
PROTOCOL: Voice prompts and indicators guide user through protocol
CHARGE CONTROL: automatic by software
CHARGE TIME from Shock Advised: < 8 Sec, typical with new battery
CONTROLS: Shock button, info-button, On/Off Button
INDICATORS: 6 Leds and 3 scenarios
WEIGHT: 2,2 Kg with battery pack installed
SELF TEST: automatic and user activated
Optional special adapter pack for data transmission to PC via USB
– Data Stored: first 60 minutes of ECG and the entire incident’s events and
analysis decisions
– PC Software for Data Management
BATTERY
-Type: 12 Volt DC, 4,2 Ah, Lithium manganese dioxide, long life
-Model number: ELRS-002
-Capacity: min 200 shocks or 4 hours of operating time continuously
-Shelf life: typically 5 years (prior to installation)
-Standby life: typically 5 years (after installation)
-Don’t install battery packs after the expiration date the battery is not rechargeable
-Don’t immerse battery pack into the water or other liquids
You must be logged in to post a review.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
Blood Pressure Apparatus M2
Blood Pressure Apparatus M2
Blood Pressure Apparatus M2 allows you comfortably, quickly and accurately check your blood pressure and monitor your results easily. Monitoring is made easy with the fully automatic digital OMRON M2 which features Intellisense Technology for soft cuff inflation. It is so easy to use you can take readings with just one touch. Features and cautions Intellisense Technology - this unique OMRON technology ensures that there is less discomfort from over-inflation of the cuff. Helps you take your blood pressure quickly and easily with one touch operation. Included cuff fits arms with a circumference of 22 - 32 cm. Specification:- Device Type: Upper Arm Blood Pressure Monitor
- Cuff Type: Medium Cuff 22-32cm
- Memory: 30 Readings
- Cuff Wrap Guide: Yes
- Blood Pressure Level Indicator: Yes
- Irregular Heart Beat Detection: Yes
- Storage Case Included: Yes
- Validation Type: Clinical Validation
- Intellisense Technology: Yes
- Stroke Prevention: Yes
- Length cm: 12.50
- Height cm: 16.50
- Depth cm: 12.00
- M2 blood pressure monitor
- Cuff
- Instruction Manual
- Blood Pressure Pass
- Batteries and Storage case
Mindray Hematology Analyzer BC-10
Mindray Hematology Analyzer BC-10
Mindray Hematology Analyzer BC-10 is undoubtedly reliable Hematology Analyzer in Pakistan and worldwide. It has Impedance method for WBC, RBC and PLT counting Cyanide free reagent for hemoglobin test. Now in order to conduct 1000 tests 02 Diluent and 01 Lyse maybe used. When we talk about Mindray Hematology Analyzer BC-10 it does not lost testing procedure and you can conduct as much tests as you can conduct on a one go.Technical Specifications:
Principles : Impedance method for WBC, RBC and PLT counting Cyanide free reagent for hemoglobin test. Parameters: 20 parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR 3 histograms for WBC, RBC and PLT 2 research parameters: NLR, PLR Sample Volume: Prediluted mode ≤20μL Whole blood mode ≤9 μL CLICK HERE TO DOWNLOAD THE CATALOG OF MINDRAY BC-10.pdf General Information: Mindray Hematology Analyzer BC-10 has advanced detailed flag information provides warning in case of abnormal cell results. High quality original reagent calibrator and quality controls maintain your work at a high level. We integrate technologies into our products to fulfill your clinical needs, therefore, today, Mindray products and services are used by healthcare facilities in over 190 countries and regions. More and more customers choose Mindray products and trust Mindray's quality. Mindray Hematology Analyzer BC-10 Quality and user experience are top priorities for Mindray. We design and manage our manufacturing processes in compliance with FDA, ISO and CE. Complete quality control systems in Mindray's manufacturing centers ensure we exceed the most stringent criteria and traceability throughout the entire process. Our professional and responsive support team makes sure your systems are kept at full capability Zirar Enterprises are the distributor of mindray in Pakistan, when we talk about the Hematology Analyzer price in Pakistan, we have one the best discounted options and Mindray Hematology Analyzer BC-10 is our bestseller. CLICK HERE TO SEE Auto Hematology Analyzer RT-7600 For more information, questions and queries please feel free to contact us +923224602203 or Email: zirarenterprises@gmail.com, info@ziarenterprises.comPatient Monitor Accuit Sign 8 MDX-USA
Patient Monitor Accuit Sign 8 MDX-USA
Patient Monitor Accuit Sign 8 MDX-USA is one of the best patient monitor equivalent to any other renowned brand, MDX USA has made it with sophisticated technology which makes Patient Monitor Accuit Sign 8 MDX-USA standing top quality patient monitor. please click here to download the product catalog Accuit Sign™ 8.pdf Feature:- High resolution 12.1"color TFT display
- Suitable for adult, pediatric and neonatal patient
- Color TFT Screen, waveform up to 8 channels
- Operation modes: Diagnostic, Monitor, Surgery
- Light and portable with Built-in rechargeable lithium battery
- UP to 10 kinds of monitor parameters
- Arrhythmia analysis, pace-marker detection and S-T Segment analysis
- 72 hour storage and review of trend grams and tables
- 500 NIBP measurement date can be storage and recall
- Electro surgical unit and defibrillation protected
- Networkable with central monitoring system
- 5-lead or 3-lead selectable
- Input: 5-lead :RA; LA; RL; LL; V or R; L; N; F; C
- ECG waveforms of 7-leads display on the same screen
- Lead selection :I; II; III; avR; avL; avF; Vx
- ECG waveform :2 channels
- Gain selection :12.5mm/s, 25mm/s, 50mm/s
- Accuracy :±1bpm or ±1%, whichever is greater
- Protection :Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation
- Calibration signal :1mV±5%
- Alarm range: Adult :15-300bpm
- Pediatric/Neonatal :15-350bpm
- Arrhythmia analysis and S-T segment analysis
- S-T segment detection Measurement rang :-0.2mv~2.0mv
- Alarm :Yes, audible and visual alarm, alarm events review
- Operation modes :Manual/Automatic/STAT
- Measurement unit :mmHg/KPa selectable
- Measurement types :Systolic, Diastolic and Mean
- Over-pressure protection :YES
- Resolution :1mmHg
- Accuracy :Mean error and standard deviation per ANSI/AAMI SP-10
- Alarm :Systolic, Diastolic, and Mean
- Auto measure time :Adjustable
- Measurement rang :10-270mmHg
- 500 NIBP measurement date can be storage and recall
- Measurement range :0-100%
- Accuracy :70-100%, ±2% 0-69%, upspecified
- Alarm range :0-100% Pulse rate
- Range :20-254bpm
- Accuracy :±3bpm
- Respiration
- Method :RA-LL impedance
- Pediatric/Neonatal :6-150rpm
- Alarm range: Adult :6-120rpm
- Pediatric/Neonatal :6-120rpm
- Apnea alarm :YES
- Channel :Dual-channel
- Alarm range :0-50℃
- Apnea :0.1℃
Patient Monitor Operon OM12
Patient Monitor Operon OM12
Specification:- 12" inched LCD Monitor with high brightness TFT colors
- VGA slot available for attaching high resolution screen such as LED's, Monitors Etc
- SPO2
- Alarm/Beep as per prescribed statistics of the patient
- Accurate Blood Pressure display.
- Heart Beat display
- Printable ECH and other statistics/diagnosis.

Reviews
There are no reviews yet.