AED Defibrillator Rescue Sam, Progetti, Italy
AED Defibrillator Rescue Sam, Progetti, Italy
Automated External Defibrillator AED Defibrillator Rescue Sam, progetti Italy helps tackle Sudden cardiac arrest (SCA) associated with ventricular fibrillation (VF) remains a leading cause of unexpected death in the Western world. It has been estimated that chances for survival from SCA decrease approximately 7% to 10% with each passing minute and that survival rates after 12 minutes are only 2% to 5%. The most common cause of SCA is ventricular fibrillation (VF), a lethal heart
rhythm, and survival depends on the rapid treatment called defibrillation, an electrical shock sent to the heart to resume normal and healthy rhythm. So early defibrillation is the sole definitive determinant of survival and is the key factor in cardiopulmonary resuscitation. Currently, fewer than 5% of the 60.000 persons who experience out-of-hospital cardiac arrest each year survival to hospital discharge.
Specification:
AED Defibrillator Rescue Sam, Progetti, Italy
Shockable rhythms: fibrillation and/or tachycardia
Not Shockable rhythms: different from VF and VT
Waveform: BTE (biphasic truncated exponential)
Impedance: compesated
Guide Lines: AAMI DF39 2010 / AHA 2010
Shock Energy Accuracy: according to IEC EN60601-2-4
Patient Isolation: type BF
Impedance: 25 – 175 Ώ
OPERATING MODE: Semi Automatic
ENERGY: 200 j Fixed as new guidelines AHA 2010
PROTOCOL: Voice prompts and indicators guide user through protocol
CHARGE CONTROL: automatic by software
CHARGE TIME from Shock Advised: < 8 Sec, typical with new battery
CONTROLS: Shock button, info-button, On/Off Button
INDICATORS: 6 Leds and 3 scenarios
WEIGHT: 2,2 Kg with battery pack installed
SELF TEST: automatic and user activated
Optional special adapter pack for data transmission to PC via USB
– Data Stored: first 60 minutes of ECG and the entire incident’s events and
analysis decisions
– PC Software for Data Management
BATTERY
-Type: 12 Volt DC, 4,2 Ah, Lithium manganese dioxide, long life
-Model number: ELRS-002
-Capacity: min 200 shocks or 4 hours of operating time continuously
-Shelf life: typically 5 years (prior to installation)
-Standby life: typically 5 years (after installation)
-Don’t install battery packs after the expiration date the battery is not rechargeable
-Don’t immerse battery pack into the water or other liquids
AED Defibrillator Rescue Sam, Progetti, Italy
Automated External Defibrillator AED Defibrillator Rescue Sam, progetti Italy helps tackle Sudden cardiac arrest (SCA) associated with ventricular fibrillation (VF) remains a leading cause of unexpected death in the Western world. It has been estimated that chances for survival from SCA decrease approximately 7% to 10% with each passing minute and that survival rates after 12 minutes are only 2% to 5%. The most common cause of SCA is ventricular fibrillation (VF), a lethal heart
rhythm, and survival depends on the rapid treatment called defibrillation, an electrical shock sent to the heart to resume normal and healthy rhythm. So early defibrillation is the sole definitive determinant of survival and is the key factor in cardiopulmonary resuscitation. Currently, fewer than 5% of the 60.000 persons who experience out-of-hospital cardiac arrest each year survival to hospital discharge.
Specification:
AED Defibrillator Rescue Sam, Progetti, Italy
Shockable rhythms: fibrillation and/or tachycardia
Not Shockable rhythms: different from VF and VT
Waveform: BTE (biphasic truncated exponential)
Impedance: compesated
Guide Lines: AAMI DF39 2010 / AHA 2010
Shock Energy Accuracy: according to IEC EN60601-2-4
Patient Isolation: type BF
Impedance: 25 – 175 Ώ
OPERATING MODE: Semi Automatic
ENERGY: 200 j Fixed as new guidelines AHA 2010
PROTOCOL: Voice prompts and indicators guide user through protocol
CHARGE CONTROL: automatic by software
CHARGE TIME from Shock Advised: < 8 Sec, typical with new battery
CONTROLS: Shock button, info-button, On/Off Button
INDICATORS: 6 Leds and 3 scenarios
WEIGHT: 2,2 Kg with battery pack installed
SELF TEST: automatic and user activated
Optional special adapter pack for data transmission to PC via USB
– Data Stored: first 60 minutes of ECG and the entire incident’s events and
analysis decisions
– PC Software for Data Management
BATTERY
-Type: 12 Volt DC, 4,2 Ah, Lithium manganese dioxide, long life
-Model number: ELRS-002
-Capacity: min 200 shocks or 4 hours of operating time continuously
-Shelf life: typically 5 years (prior to installation)
-Standby life: typically 5 years (after installation)
-Don’t install battery packs after the expiration date the battery is not rechargeable
-Don’t immerse battery pack into the water or other liquids
You must be logged in to post a review.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
Autoclave Double Drum 30 LBS Pakistan
Autoclave Double Drum 30 LBS Pakistan
Autoclave Double Drum 30 LBS Pakistan is a best featured and manufactured product by Zirar Enterprises, We are one of the top leading manufacturer and distributor of autoclaves in Pakistan. We are manufacturing top-notch sterilizers and autoclaves in Pakistan. As we are the manufacturer of autoclaves so we can build or modify autoclaves according to your needs. Why Autoclave? or Autoclave Double Drum 30 LBS Pakistan Autoclave provides a physical method for sterilization in order to kill bacteria, microorganisms and spores. They are used to decontaminate certain biological waste and sterilize media, instruments and lab ware also it is highly recommended to sterilize medical instrument before disposing it off. Autoclave Double Drum 30 LBS Pakistan and Accessories Zirar Enterprises not only stops at autoclaves but we are also providing wide range of accessories to use before handling autoclaves for e.g. (Lab Coats, Safety Goggles, Safety Gloves and Shoes). Types of Autoclaves for Sale in Pakistan- Horizontal Autoclaves & sterilizers
- Vertical Autoclaves & sterilizers
- Electrical and Gas Autoclaves
- Fully SS (stainless steel autoclaves)
- MS & SS autoclaves
- Capacity: Auto clave 100L (16x30) Horizontal
- Drum: Double chamber (Jacket & Chamber)
- Material: MS Mild steel and SS Stainless steel (SS sheet size 2.5 MM for double chamber and 1.5 for single chamber)
- Working pressure: 30 – 35 pound (can be used up to 50-pound pressure if needed)
- Power: Electric 3 phase + Gas
- Wika Gauges: Water pressure gauge, steam pressure gauge and chamber pressure gauge.
- Valves: Safety valves & emergency steam release valves.

Reviews