Showing 75–76 of 163 results

IBP Patient Monitor CMS7000

IBP Patent Monitor CMS7000

IBP Patient Monitor CMS7000 by Contec Medical is a portable and most reliable Patient Monitor. It is also listed in the FDA (USA) which means it has also approval of the FDA. IBP Patient Monitor CMS7000 has 5 Function and 2 IBP ports. It is used widely in many Hospitals, Clinics etc. It is also shows Real-Time Vital Signs which makes it acceptable in the ICU, CCU etc. IBP Patient Monitor CMS7000 can monitor such parameters as ECG, RESP, SpO2, PR, NIBP and dual-channel TEMP, etc. IBP Patient Monitor CMS7000 can monitor such parameters as ECG, RESP, SpO„ PR, NIBP and dua I-channel TEMP, etc. It integrates parameter mea- surement module, display and recorder in one device to form compact and portable equipment. At the same time, its built-in replaceable battery provides convenience for patient moving. Functions - IBP Patient Monitor CMS7000 Standard parameters: ECG, RESP, SpO„ PR, NIBP, dual-channel and TEMP Features:
  • 12.1" TFT color LCD, multi-language interface: Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish (Europe) , Spanish ( Mexico) ,Portuguese, Italian, Dutch, Romanian, Russian, Kazakh, Polish, Czech, Bulgarian, Ukraine.
  • Efficient design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
  • Alt-round monitor for adult, pediatric and neonate.
  • With standard interface, OxyCRG, trend chard, big character interface and view bed, convenient to observe.
  • Waveform, parameter color and location can be set optionally.
  • Operation mode: keys and buttons.
  • Display up to 8-channel waveform on one screen.
  • Display 7-lead ECG waveform on one screen, and with ECG step function.
  • Adopt digital SpO, technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
  • HRV analysis function.
  • NIBP measurement mode: Manual/AUTO/Continuous, storage for 4800-group NIBP data.
  • Review for 71 alarm events of all parameters and 60 arrhythmia.
  • Weight <3 Kg excluding Accessories.
  General Information: When we talk about the Invasive Patient Monitor price in Pakistan or IBP Patient Monitor in Pakistan we have IBP Patent Monitor CMS7000 available at all certain critical times. IBP Patient Monitor CMS700 is Non Invasive Patient Monitor in Pakistan and it also has the capability to have non Non-Invasive Patient Monitor (NIBP Patient Monitor in Pakistan). For more information feel free to contact us +923224602203 Call or Whatsapp

ICU Ventilator Lifepro 8 MDX-USA

ICU Ventilator Lifepro 8 MDX-USA

ICU Ventilator Lifepro 8 MDX-USA are designed for the most demanding ICU environments. Built to last, the LifePro 8 ICU ventilator offers robust and consistent performance when its needed. Click the link to download complete catalog  LifePro™ 8 ICU VENT.pdf

ICU Ventilator Lifepro 8 MDX-USA

Features
  • 12.1 inch TFT color screen , big screen could show more information.
  • Screen could be rotated freely, suitable to operate in any angle and height
  • With heater device to prevent water into ventilator
  • Could show Paw-t、Flow-t、Volume-t、Paw-V、Flow-V five waveform at the same time, also could show one or
  • several waveform according to our operation.
  • Curve size ,time scale, pressure-flow ratio adjustable, watch the details more good.
  • Curve pause function, could watch details.
  • Flow, pressure two trigger function, could effect at a same time.
  • Automatically inspiratory synchronous nebulizing function, nebulizing time adjustable;
  • 100% Oxygen inspiratory function, oxygen inspiratory time is adjustable.
  • High, medium, low- grade alarm function;
  • Alarm record functions, could record the last 100 pieces of information, show alarm grade, alarm time and the alarm
  • parameter.
  • Pressure, volume, time respiratory mode security, could inspect pressure in inspiratory phase, volume, time exceed the
  • regulated value, turn into expiratory, ensure patient safety.
  • Volume security function, keep the minimum tidal volume in pressure mode.
  • Adjust MMV function automatic, adjust inspiratory pressure and breathing frequency, approaching the target tidal
  • volume
  • and minute ventilator.
  • VGA connector could output the screen signal to other screen
  • Specification
Operating Modes
  • Volume Control Ventilation (VCV)
  • Assisted/Controlled Pressure Control Ventilation (PCV),
  • Assisted/Controlled Pressure Support Ventilation (PSV),
  • SIMV(VCV)+PSV
  • SIMV(PCV)+PSV
  • Mandatory Minute Ventilation (MMV)
  • Continuous Positive Airway Pressure(CPAP)
Parameter
  • Application scope: Pediatric and adult
  • Driven mode: pneumatically driven and electronically controlled
  • Display:12.1 TFT screen
  • Working mode: Pressure and volume
  • Ventilation wave type: squire wave, deceleration wave
  • FiO2: 21% to 100%
  • PEEP/CPAP: 0 to 40 cmH2O
  • Inspiratory Sensitivity:
  • Flow triggered: 0.5 to 20 L/min, OFF
  • Pressure triggered: -1 to -20 cmH2O, OFF
  • Tidal Volume: 20 to 2000 mL
  • Breath frequency: 1 to 100 bpm
  • I:E Ratio: 5.0 : 1 to 1 : 5.0
  • Inspiratory plateau: 0 to 50%
  • Inspiratory Flow Wave Shape(VCV): Rectangular wave and Decelerating wave
  • SIGH: 1.0 to 2.0
  • Breath frequency(SIMV): 2 to 40bpm
  • Inspiratory time (SIMV): 0.1 to 12 S
  • Pressure Support Ventilation (PSV): 0 to 40 cmH2O
  • Expiratory Sensitivity for PSV : 10% to 75% of the initial flow
  • Maximum Inspiratory time (PSV): 1.0 to 8.0 S
  • Pressure Control Ventilation(PCV): 0 to 40 cmH2O
  • Minimum Tidal Volume(PCV and PSV): 50 to 1500 mL
  • Backup Rate (PSV): 2 to 40 bpm
  • Object Tidal Volume(MMV): 20 to 2000 mL
  • Ventilation volume(MMV): 0.5 to 40.0 L/min
  • Nebulizer time: 30 minutes
Monitoring
  • Breathing wave: Pressure vs time curve,Flow vs time curve,Volume vs time curve,Pressure vs volume loops,Flow vs volume loops
  • Expiratory tidal volume:,
  • Breath frequency(bpm),
  • PEEP:
  • FiO2
  • MV
  • Insipiratory Tidal volume(TV_Insp):
  • I:E ratio:
  • Freq_indepen:
  • MV_Indepen:
  • Pmean
  • Pflat:,
  • Airway Pressure
  • Ppeak,
  • Minute Ventilation,
  • Oxygen concentration
Alarms
  • High tidal volume alarm
  • Low tidal volume alarm
  • High minute ventilation alarm
  • Low minute ventilation alarm
  • High breathing frequency alarm
  • Low breathing frequency alarm
  • High peak pressure alarm
  • Low peak pressure alarm
  • High PEEP pressure alarm
  • Low PEEP pressure alarm
  • High oxygen concentration alarm
  • Low oxygen concentration alarm
  • Apnea time alarm
  • Respirtory arrest alarm
  • AC power fail alarm
  • Air source Low pressure alarm
  • Oxygen source low pressure alarm
  • Batterydisconnect alarm
  • Low battery alarm
  • Circle leakage alarm
  • Circle block alarm
Air compressor BC100 (Optional) Feature: Low noise medical air Compressor, very stable performance, safe and reliable, Air Compressor with LCD screen to display output pressure, provide safe, secure and permanent motivation Compact design and easy to transfer Assembled with clean control module, supplying cleaner and safer air to the patients Effective sound-absorbing materials Match with various ventilator of international standard in the world Specification
NO. Name Specifications Notes
1 Output gas flow ≥40L/min
2 Output gas pressure 0.3~0.4Mpa Adjustable
3 Output gas filter accuracy 0.03μm
4 Air compressor pump 1sets
5 Efficient rate for particle filtration 99%
6 Dew point of output gas: 0~10℃ Dried output gas
7 Noise 46~48dB(A)
8 Power supply 220V±15% ,50HZ or 110V±15%,60HZ
9 Power <800W
10 Working Environment Temperature 0~40°C Humidity<90RH
11 Net Weight

40kg

12 Size

510*560*610mm

POWER REQUIREMENT Main power: from 85 to 265VAC 47-63HZ Automatic voltage switch Internal battery: 12VDC; 7AH Automatic recharge. Estimated duration: more than 2 hours when completely charged. The display shows an icon with the charge level. PNEUMATIC REQUIREMENT Oxygen: pressure 2.8 to 6 bar ISO5359 connector Air: pressure 2.8 to 6 bar ISO 5359 connector