Defibrillator Rescue life

Defibrillator Rescue life

Defibrillator Rescue life is Designed to be the ideal device to deal with cardiovascular emergencies and to monitor the patient in hospital and non-hospital environments. Thanks to its compact and shockproof design. RESCUE LIFE is the best ally for hard times. When time becomes an enemy, thanks to its intuitive navigation interface RESCUE LIFE lets the user initiate its functions in a fast and easy way. Developed with the purpose to satisfy the most elevated demands, RESCUE LIFE guarantees a complete monitoring of the patient in a critical situation: blood pressure, saturation and 12-leads ECG allow the user to have a clear picture of the clinical situation. With its state-of-the-art biphasic technology, RESCUE LIFE guarantees the maximum effectiveness in the shortest time. RESCUE LIFE means versatility. TECHNICAL SPECIFICATIONS GENERAL SPECIFICATIONS Dimension • 369 x 240 x 340 mm Weight • 5,5 Kg with battery Electrical •• AC 100-240 VAC, 50/60 Hz- inverter12V car adapter (optional) Rechargeable 14.4 V - 2 Ah NiMh battery Capacity • 100 shocks at 230J with battery fully charged Software • Voice and texts multilanguage Memory • Internal flash 4 Gb up to 300 hrs of ECG data, events and usage review ENVIRONMENTAL Temperature ••• Operational -5° ~ 55° C Storage -20° ~ 70° C Relative humidity 10 ~ 95% Isolation • ECG type CF, Defibrillation type BF Water proof • Class IPX4 DEFIBRILLATION Waveform •• Bipashic Truncated Exponential (BTE) HiCAP technology (Large storage capacitor) Impedance • Compensated, range 25 - 200 Ohm Charge time • 6 sec for 230 J with battery fully charged AED MODE (OPTIONAL) Energy • Fixed energy at 200 J Protocol • AHA 2010 CPR Guidelines with voice and text prompts Shockable rhythms • VF with amplitude > 100 μV and VT with rhythm >150 bpm Sensitivity •• Shockable rhythm-VF > 95% Shockable rhythm-VT > 75% Specificity ••• According to AHA 2010 Normal sinusoidal rhythm > 99% Asystole and other non-shockable rhythms > 95% MANUAL MODE Energy range • 1 - 230 J (from 1-10 J in 1 J steps; from 10 to 230 J in 10 J steps) Commands • Multifunction trim knob. Charge and shock button directly in the front panel for hands free defibrillation Paddles •• Reusable adult & pediatric defi paddles with charge/shock command Disposable defi pads and internal defi paddles (optional) Operating mode • ECG « R » wave synchro or asynchro mode Indicators •• Battery and main led indicators Clear and visible backlight color buttons DISPLAY Type • High contrast TFT color LCD 5.7” (320 x 240 pixels) Information • Operational information, ECG traces, Spo2 value, NIBP values, parameters, Heart Rate indicator, filters, alarms and battery status ECG MONITORING Bandwidth • 0.5 - 120 Hz (-3 db) with filters off CMRR • > 90 db Input impedance • > 20 Mohm Input •• Patient cable 5 leads (I,II,III,aVL,aVR,aVF) - standard Patient cable 10 leads (12 channels ECG) - optional Gain • 5, 10, 20 mm/mV with patient cable. AUTO with pads Velocity • 5, 10, 25, 50 mm/sec Filters • 50/60 Hz, EMG Filter, base line HR range • 20 - 300 bpm (~ 2%), digital readout on the display Alarm • HR max settable 250 bpm; HR min 20 bpm SPO2 (OPTIONAL) SpO2 range • 0 - 100% HR range • 18 - 300 ppm Accuracy • 70 - 100% ~ 2% for adults with finger clip sensor Alarm • Adjustable min 65% PRINTER Type • Integrated thermal printer for ECG traces and events documentation hardcopy including HR/SpO2/NIBP values Paper speed • 5, 10, 25, 50 mm/sec Paper width • 58 mm Operating model • Manual, automatic (10” pre and post shock recording) EXTERNAL PACEMAKER (OPTIONAL) Type • Rettangular wave Operating mode • Fixed on demand Pulse rate • 30 ppm to 250 ppm, adjustable in steps of 5 ppm Impulse duration • 22 ms Pulse current • 0 to 150 mA adjustable in steps of 5mA Amplitude • Max 150 V STANDARDS & SAFETY Standard • IEC 60601-2-4; IEC 60601-1; IEC 60601-1-2, Class II, type BF CE Mark EEC 93/42 • Medical device, class IIb Specifications and contents of this document subject to change without notice.