Oxygen Suction Flowmeter Precision UK
Oxygen Suction Flowmeter Precision UK
Oxygen Suction Flowmeter Precision UK – The Precision CPX Bubble flow meter shall be supplied with connection probes to BS 5682, other country standards available e.g. DIN, NFPA, AFNOR, JIS, SS, ISO European
Gas Specificity
Flow meter’s shall be supplied with gas specific probes and only attach to the corresponding medical gas terminal unit, it accurately measures flow at 0-15Lpm even at variant inlet pressures. Accuracy is fulfilled within 10% to attain maximum efficiency for patient and environment.
Each flow meter is calibrated at 50 psi inlet pressure
Materials
Flow meter shall be manufactured to EN 13220:1999 and ISO 15002:2008 and constructed from chromium-plated brass body, inner and external tube in crack resistant polycarbonate and stainless steel ball. Other pieces shall be in brass.
Humidifier:
Constructed from polycarbonate, Sterilisation should be conducted in an autoclave on a 25 min cycle at 121 ºC, 1.3 kPa (max. 40 times). Before sterilisation remove the tube and diffuser and consequently disposed.
Quality:
Manufactured under BS EN 13485 Medical Devices: Quality Management Systems and carries CE0086 Class IIb Medical Device certification.
Warranty
The flow meter shall have a two-year warranty, subject to the recommended minimum routine maintenance operations being carried out by correctly competent persons.
For more information regarding rates, quotations, queries or any questions please feel free to contact us at +92-322-4602203 Email: zirarenterprises@gmail.com, info@zirarenterprises.com
Oxygen Suction Flowmeter Precision UK
Oxygen Suction Flowmeter Precision UK – The Precision CPX Bubble flow meter shall be supplied with connection probes to BS 5682, other country standards available e.g. DIN, NFPA, AFNOR, JIS, SS, ISO European
Gas Specificity
Flow meter’s shall be supplied with gas specific probes and only attach to the corresponding medical gas terminal unit, it accurately measures flow at 0-15Lpm even at variant inlet pressures. Accuracy is fulfilled within 10% to attain maximum efficiency for patient and environment.
Each flow meter is calibrated at 50 psi inlet pressure
Materials
Flow meter shall be manufactured to EN 13220:1999 and ISO 15002:2008 and constructed from chromium-plated brass body, inner and external tube in crack resistant polycarbonate and stainless steel ball. Other pieces shall be in brass.
Humidifier:
Constructed from polycarbonate, Sterilisation should be conducted in an autoclave on a 25 min cycle at 121 ºC, 1.3 kPa (max. 40 times). Before sterilisation remove the tube and diffuser and consequently disposed.
Quality:
Manufactured under BS EN 13485 Medical Devices: Quality Management Systems and carries CE0086 Class IIb Medical Device certification.
Warranty
The flow meter shall have a two-year warranty, subject to the recommended minimum routine maintenance operations being carried out by correctly competent persons.
For more information regarding rates, quotations, queries or any questions please feel free to contact us at +92-322-4602203 Email: zirarenterprises@gmail.com, info@zirarenterprises.com
You must be logged in to post a review.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
Bed Head Unit Horizontal
Bed Head Unit Horizontal
Bed Head Unit Horizontal widely used in hospitals and which provides patients a good care, backed by invisible medical gas copper pipe lines, electric sockets it is pertinent to notice that we at Zirar Enterprises have installed these units in many renowned hospitals. please feel free to contact us anytime for assistance +923224602203 If you want bed head unit vertical then click on this link bellow Bed Head unit verticalBed Head Unit Vertical
Bed Head Unit Vertical
Bed Head Unit Vertical is our specialty we at Zirar Enterprises install, assemble, fabricate and manufacture Bed Head Unit Vertical types and their composition are additionally extreme basic piece of the clinics, hospitals etc and it not only facilitate patients but also gives accommodation to the paramedic and nursing staff for better vertical view and to perform their life saving duties. Further essential advantage of vertical bed head unit is that it covers less space as compared to horizontal bed head units. Our specialized staff is totally all around, prepared and well taught in this specific field. please feel free to contact us anytime, we shall be glad to pay free visit, testing and commissioning. For post view click on this link Bed Head Vertical Technical Specification: - Material: Material is made of 99.9% pure aluminum, extruded from imported billet. Thickness: 2mm Size of Bed head unit: Standard size is 4 feet, but you can also customize as per your discretion. Paint: Jotun paint which is powdered coated, you can also choose paint of your choice. Color: Color can also be customize of customer's choice. Electrical Equipment: Clipsal, Australia. Electrical Accessories: 01 on and 01 off switch with 01 multi functional two pair of schuko sockets. Our valued clients can also modify it with their discretionary electrical accessories. Electrical Cables: For vertical bed head units we use one of the best electrical cables such as GM Cables, Newage Cables and Pakistan cables. However customer can also choose the cable brand as per their feasibility and budget. Patient Light: 600mm LED Light. Warranty: One year warrant with after sale service within a year, and 02 years paint warranty. Projects Completed:- Dow Medical University, Karachi
- Sheikh Zaid Hospital, Lahore
- Women Medical College, Islamabad
- Combined Military Hospital, Rawalpindi
- Ali Medical Complex, Islamabad
- Jinnah Hospital, Lahore
- Doctors Hospital, Lahore
- Omer Hospital, Lahore
- Rehman Medical Institute Peshawar
Degreased Medical Gas Copper Fittings
Degreased Medical Gas Copper Fittings
Degreased Medical Gas Copper Fittings CPX end feed copper fittings a.k.a Degreased Medical Gas Copper Fittings are manufactured in the UK under BS EN 13485 Medical Devices: Quality Management Systems. They are suitable for jointing degreased medical gas copper tube pipelines compliant to BS EN 13348, BS EN 1057 and BS 2871 Part 1 Table X as quoted in HTM 02-01 and C11. Exclusively designed for Medical Gas Pipeline Systems (MGPS), CPX copper fittings recognize and embrace the specialist requirements of the medical gas pipeline industry to include all aspects of design, cleanliness, packaging and usability required to become a successful partner for installations of pipelines compliant with HTM 02-01, C11 and BS EN 7396. Specification: -- All CPX degreased copper fittings are engraved with the following information: EN 1254, size, manufacturer details.
- Each fitting is individually bagged in a clear protective polythene bag and sealed to maintain cleanliness
- Each bag is labelled with the degreased specification, product code and production batch number.
- Cleanliness is guaranteed below 0.01 mg/cm² of hydrocarbons on the degreased surface of the fitting.
- All boxes include logical and concise labeling identification.
- 25 Year guarantee.
- Available in all sizes
Designing and planning of ICU
Designing and planning of ICU
For Designing and planning of ICU. We have one best expertise in designing and planning of intensive care unit (ICU) we have ample experience in this category. We already manufactured and installed it to one of the best and renowned hospitals nation wide for more information please contact 0322-4602203Designing and Planning of Nursery
Designing and Planning of Nursery
Designing and Planning of Nursery in Hospital(s) nurseries are also very important infrastructure for the new born babies. We have ample experience in manufacturing, installing and importing the hospital nursery equipment. Our qualified staff is expert in manufacturing the whole pediatrics ward including all the equipment required therein. please contact for more information 0322-4602203Manual/Semi Automatic Manifold Systems
Manual/Semi Automatic Manifold Systems
Manual/Semi Automatic Manifold Systems main using at small and medium hospitals. When using the medical gas oxygen manifold, several cylinders need to be connected to the manifold pipeline. The oxygen gas is first filtered and decompressed, and then transported through the main pipe to the end of use. The function of the secondary regulator is to stabilize the outlet gas flow of the main pipeline. CGA standard adapter port and inlet connection thread. Cleaned for medical Oxygen, Air, N2O, CO2 gas. Open type manifold connector cylinder number according to the client request. 3 years warranty. Specifications:- Applicable gas: O2, Air, CO2, N2, and N2O etc.
- High flow capacity regulator
- Open style cylinder number according to the client request
- Pass the pressurization testing, welded in silver, much safety and stable
- Wall mount simplifies installation, easy installed
- Size of the connecting hose is customized
- CGA4.1 and ISO15001 Standard
- Maximum pressure 3,000 psi
General Information:
An oxygen manifold system is a critical component in the delivery of oxygen in medical facilities. The system consists of a series of oxygen cylinders connected to a common manifold, which regulates the flow of oxygen to different parts of the hospital or clinic. The manifold system ensures a continuous supply of oxygen to patients, even if one cylinder runs out of gas. The manifold system is designed to be reliable and durable, and it is typically made of high-quality materials that can withstand the high pressures of oxygen gas. The manifold system can be configured in different ways depending on the specific needs of the medical facility. For example, some manifold systems may be designed to supply oxygen to a single ward or room, while others may supply oxygen to multiple floors of a hospital. One of the benefits of an oxygen manifold system is its ability to provide a centralized source of oxygen, which can reduce the need for multiple oxygen tanks scattered throughout a facility. This can make it easier to manage the inventory of oxygen tanks and reduce the risk of running out of oxygen during a medical emergency. Overall, an oxygen manifold system is an essential component of any medical facility that requires a reliable supply of oxygen for patient care. Proper maintenance and monitoring of the system are crucial to ensure its continued reliability and safety. Manufactured by AMCAREMED Please click to read Medical Gas and Pipeline Network For more information please feel free to call us at+92-322-4602203 or Email: info@ziarenterprises.com, zirarenterprises@gmail.comMedical Air Plant – British Standard
Medical Air Plant - British Standard
Medical Air Plant - British Standard - Precision UK’s CPX Medical Air Plant is manufactured under BS EN 13485 Medical Devices: Quality Management Systems. It provides a centralized source of medical air, available in simplex to multi-pump configurations dependent on individual requirement.
Specification:
- Specific Benefits Include
- Fully complies to HTM 02-01, HTM 2022, C11, BS EN 7396, CE0086 Class IIb
- CE marked under Medical Device Directive 93/42/EEC
- CPX® branded solid British design
- Control and highly visible indication panel
- All interconnecting pipework is included
- Outlet pipework for connecting to the pipeline
- Anti-vibration mounts on all compressors
- Isolator to each pump unit as standard
- Alarm and BMS outputs for remote status indication
- Digital display touchscreen with user interface
- 400Kpa, 700Kpa and 1000Kpa output versions available
- All settings are factory set and verified with certificates of inspection
- Each plant has a full warranty of 12 months from its commission date
Medical Gas Outlets Precision UK
Medical Gas Outlets Precision UK
Medical Gas Outlets Precision UK also known as CPX Terminal Units are designed and manufactured in the UK under BS EN 13485 Medical Devices: Quality Management Systems. The units comprise of a first fix, second fix and a second fix valve assembly and connect medical appliances to the gas supply system. Please also see our Medical Gas Outlets Precision UK & Medical Gases & Infrastructure The first fix comprises of a brass pipeline termination cylinder with a 12mm BS EN 13348 copper pipe for brazing to the fixed pipeline system, or with a NIST BS EN 18082 (non-interchangeable screw thread) connector for connection to a hose assembly. A mounting box suitable for both surface and flush installations is also provided. CPX British Standard and DIN Standard Gas Outlets utilize a common first fix assembly. The CPX Terminal Unit is designed to enable gas probes to be connected and disconnected easily and with minimal effort and the same time as giving a strong, reliable and secure connection. They are available for oxygen, nitrous oxide, 50% oxygen/50% nitrous oxide mixture, medical air, surgical air, medical vacuum, carbon dioxide, nitrogen and AGSS. The terminal units can be flexibly integrated into any type of installation including surface, flush, bedhead and pendant and are supplied with a 3 year warranty. Test plugs are included with flush, surface, and bedhead types for first fix pressure testing on site. DIN Standard CPX DIN gas outlets are manufactured and designed in our UK factory, full metal construction, Gas Indexing as EN 13260-2, EN 9170 and Medical Gas Pipelines EN 7396.
Standards: Designed to Meet the requirements of
Medical Gas Outlet Precision UK
- HTM 02-01 Medical gas Pipeline Systems
- BS EN 7396-1 Pipelines for Compressed medical Gases and Vacuum
- BS EN 7396-2 Anaesthetic Gas Scavenging Disposal Systems
- BS EN 9170-1 Terminal Units for use with Compressed Medical Gases and Vacuum
- BS EN 9170-2 Terminal Units for Anaesthetic Gas Scavenging Systems
- C11 NHS Model Engineering Specification – Medical Gases
- BS EN 18082 Non-interchangeable Screw Threaded (NIST) Low-pressure Connectors for Medical Gases
- BS 5682 Specification for Probes Specification for Probes (quick connectors) for Medical Gases.
- Medical Device Directive 93/42/EEC (CE0086) Class IIb.
- DIN 13260-2 Part 2: Dimensions and allocation of Probes and Gas specific connection points for Terminal Units
- Available for Oxygen, Nitrous Oxide, Medical Air, CO2, Motor Air and Vacuum (other gases available on request)
- Incorporating a 12mm copper stub pipe to EN 13348 to allow easy connection to the Medical Gas Pipeline system, other options include NIST or DISS type fittings for pendants or bed head units.
- Probe insertion design incorporates parking position and full insert for 100% operation, each outlet is supplied with Flush/Surface Box or Bed Head Plate mounting options and include a 3-year warranty.
- CE marked CE0086 Class IIb Medical Device.