AED Defibrillator FRED PA-1 Schiller

AED Defibrillator FRED PA-1 Schiller

AED Defibrillator FRED PA-1 Schiller Dedicated to public access, SCHILLER’s latest defibrillator, the FRED PA-1, has been designed so that even untrained users can save lives. The FRED PA-1 guides the rescuer step-bystep during the entire resuscitation process. Defibrillation consists in delivering electrical energy to the heart in order to restore a proper heart rhythm. A defibrillator in combination with well-performed chest compression is the only therapy that can save a patient’s life. The FRED PA-1 is a well-designed lifesaving equipment, which is highly visible and clearly recognizable in all environments. For complete specification please click here AED Schiller.pdf  to download the catalog HIGHEST USER-FRIENDLINESS In emergency situations, procedures that would normally be clear and easy to follow can suddenly become confusing. Every detail counts and can make a difference in saving lives. That’s why a defibrillator needs to be as simple as possible. 1-2-3 STEPS Not only is the user interface streamlined with 1-2-3 steps, but spoken instructions and clear pictures also guide the user through the process. NO DELAY When you lift up the device cover, the FRED PA-1 starts up immediately. The electrodes are pre-connected: apply them to the patient’s chest and let the FRED PA-1 guide you. SHOCK DELIVERY POSSIBLE AS SOON AS A SHOCK IS RECOMMENDED Resuscitation Guidelines emphasis the importance of minimizing the time-to-shock after Cardio Pulmonary Resuscitation (CPR). In order to reduce the hands-off time (time while no CPR can be performed), the FRED PA-1 features a fast analysis system that systematically pre-charges the correct energy so that the shock can be delivered as soon as it is recommended.

AED Defibrillator Rescue Sam, Progetti, Italy

AED Defibrillator Rescue Sam, Progetti, Italy

Automated External Defibrillator AED Defibrillator Rescue Sam, progetti Italy helps tackle Sudden cardiac arrest (SCA) associated with ventricular fibrillation (VF) remains a leading cause of unexpected death in the Western world. It has been estimated that chances for survival from SCA decrease approximately 7% to 10% with each passing minute and that survival rates after 12 minutes are only 2% to 5%. The most common cause of SCA is ventricular fibrillation (VF), a lethal heart rhythm, and survival depends on the rapid treatment called defibrillation, an electrical shock sent to the heart to resume normal and healthy rhythm. So early defibrillation is the sole definitive determinant of survival and is the key factor in cardiopulmonary resuscitation. Currently, fewer than 5% of the 60.000 persons who experience out-of-hospital cardiac arrest each year survival to hospital discharge. Specification: AED Defibrillator Rescue Sam, Progetti, Italy Shockable rhythms: fibrillation and/or tachycardia Not Shockable rhythms: different from VF and VT Waveform: BTE (biphasic truncated exponential) Impedance: compesated Guide Lines: AAMI DF39 2010 / AHA 2010 Shock Energy Accuracy: according to IEC EN60601-2-4 Patient Isolation: type BF Impedance: 25 – 175 Ώ OPERATING MODE: Semi Automatic ENERGY: 200 j Fixed as new guidelines AHA 2010 PROTOCOL: Voice prompts and indicators guide user through protocol CHARGE CONTROL: automatic by software CHARGE TIME from Shock Advised: < 8 Sec, typical with new battery CONTROLS: Shock button, info-button, On/Off Button INDICATORS: 6 Leds and 3 scenarios WEIGHT: 2,2 Kg with battery pack installed SELF TEST: automatic and user activated Optional special adapter pack for data transmission to PC via USB - Data Stored: first 60 minutes of ECG and the entire incident’s events and analysis decisions - PC Software for Data Management BATTERY -Type: 12 Volt DC, 4,2 Ah, Lithium manganese dioxide, long life -Model number: ELRS-002 -Capacity: min 200 shocks or 4 hours of operating time continuously -Shelf life: typically 5 years (prior to installation) -Standby life: typically 5 years (after installation) -Don’t install battery packs after the expiration date the battery is not rechargeable -Don’t immerse battery pack into the water or other liquids