Showing all 2 results

Capacitative High Voltage Detector (Contact)

Capacitative High Voltage Detector (Contact) – For price and quotes please call us at 03224602203 or email us at info@zirarenterprises.com, zirarenterprises@gmail.com

Features: 

● Excellent shock resistance.
● Rugged nylon moulding.
● Auto on (when voltage detected).
● Excellent drop resistance.
● Good vibration resistance.
● Loud sound alarm indication.
● Built-in proving and self-test circuit.
● High bright color-coded LEDS.
● Works from standard 9V battery.
● Interchangeable contact electrode.
● Use in all whether conditions.
● Compatible with all link sticks.
● Lightweight, robust & compact.
● Models available from 11kV to 132kV.
● Suitable for indoor and outdoor use.
● Self(auto on) or manual arming.
● Easy access to batteries.
● Customized threshold on demand.
● Auto off (if no voltage detected).
● Waterproof design, protection class : IP65.

 SPECIFICATIONS
 

 PART/Model #

 212HVD

 213HVD

 214HVD

 215HVD

 216HVD

 System Voltage

 4/15kV

 11kV

 33kV

 66kV

 132kV

 Threshold
Set within
Range

 1.9kV
To
2.1kV

 1.65kV
To
4.4kV

 4.95kV
To
13.2kV

 11kV
To
13kV

 11kV
To
13kV

 Response Time

 <1 Sec

 <1 Sec

 <1 Sec

 <1 Sec

 <1 Sec

 Auto-OFF

 3Min

 3Min

 3Min

 3Min

 3Min

 Bridging
Protection

 YES

 YES

 YES

 YES

 YES

 Spark Protection

 YES

 YES

 YES

 YES

 YES

 Battery Low

 <7V

 <7V

 <7V

 <7V

 <7V

 Threshold

 2.0kV

3.02kV

9.07kV

12kV

12kV

 Battery Current

 <30mA

 <30mA

 <30mA

 <30mA

 <30mA

 Green = Armed

 YES

 YES

 YES

 YES

 YES

 Red = V Detected

 YES

 YES

 YES

 YES

 YES

 Test / Arming Button

 YES

 YES

 YES

 YES

 YES

 PART#

 217HVD

 218HVD

 219HVD

 220HVD

 221HVD

 System Voltage

 11/33kV

44/132kV

66/132kV

6.6/132kV

11/132kV

 Threshold
Set within
Range

3.3kV
To
4.95kV

11kV
To
13kV

11kV
To
13kV

2kV
To
3kV

4.4kV
To
6.6kV

 Response Time

 <1 Sec

 <1 Sec

 <1 Sec

 <1 Sec

 <1 Sec

 Auto-OFF

 3Min

 3Min

 3Min

 3Min

 3Min

 Bridging
Protection

 YES

 YES

 YES

 YES

 YES

 Spark Protection

 YES

 YES

 YES

 YES

 YES

 Battery Low

 <7V

 <7V

 <7V

 <7V

 <7V

 Threshold

4.12kV

12kV

12kV

2.5kV

5kV

 Battery Current

 <30mA

 <30mA

 <30mA

 <30mA

 <30mA

 Green = Armed

 YES

 YES

 YES

 YES

 YES

 Red = V Detected

 YES

 YES

 YES

 YES

 YES

 Test / Arming Button

 YES

 YES

 YES

 YES

 YES

 PART/MODEL #  222HVD  223HVD  224HVD  225HVD  226HVD
 System Voltage

11/44kV

33/132kV

44kV

kV USER
DEFINED

12/36kV

 Threshold
Set within
Range

4.4kV
To
5kV

11kV
To
13kV

6.6kV
To
17.6kV

Xx kV
To
Xx Kv

5.0kV
To
6.0kV

 Response Time

 <1 Sec

 <1 Sec

 <1 Sec

 <1 Sec

 <1 Sec

 Auto-OFF

 3Min

 3Min

 3Min

 3Min

 3Min

 Bridging
Protection

 YES

 YES

 YES

 YES

 YES

 Spark Protection

 YES

 YES

 YES

 YES

 YES

 Battery Low

 <7V

 <7V

 <7V

 <7V

 <7V

 Threshold

4.75kV

12kV

12kV

User’s Spec

5.4kV

 Battery Current

 <30mA

 <30mA

 <30mA

 <30mA

 <30mA

 Green = Armed

 YES

 YES

 YES

 YES

 YES

 Red = V Detected

 YES

 YES

 YES

 YES

 YES

 Test / Arming Button

 YES

 YES

 YES

 YES

 YES

High Voltage Proximity Detector – 275 HP – SEW

High Voltage Proximity Detector – For prices and quotes please call us at 03224602203 or email us at info@zirarenterprises.com, zirarenterprises@gmail.com

High Voltage Proximity Detector The 275 HP is a high voltage proximity detector. It has eight voltage detection settings from 240Vac to 275kVac. The 275 HP consists of an internal pickup sensor plate, a sensitivity selector, and both visual and audio annunciators. Physical contact with electrical conductors is not necessary when testing for live lines since the 275 HP has a proximity sensor. It senses the radiated field which surrounds live conductors. Radiated field strength increases with voltage and decreases quickly with distance or earth shielding. (See “Limitations of use” paragraph in the instruction manual). Detecting distance of a 250Vac single live wire is approximately 10cm. With a bunched neutral and earth cable, as in a flexible cable, the distance is reduced to 5cm. Some typical uses of the 275 HP are: identifying and checking live cables, finding faults in flexible cables, tracing live wires, checking high frequency radiation, and detecting residual or induced voltages. For example, faults in damaged flexible cables are found by applying low voltage to each
conductor, earthing the remainder, and moving the tester along the cable until a change in condition is obtained. (Flexible cables which are used in mining and building industries, are readily repairable when the break in the cable is located.) When testing for high voltage, the rotary switch (attenuator) is used to identify and differentiate various H.V. live cables. The detector must be used in conjunction with a long insulated rod when measuring high voltage (kV). The 275 HP is a non-contact proximity tester only, and should never come into contact with live high voltage wires.
Checking or proofing the tester is easy. Switching the sensitivity to 240V and placing the dome against a low voltage
live conductor, or rubbing the dome with a cloth or an item of clothing, generates a static DC which triggers the detection
circuit. The light and beeper should go “on” as if a live wire is being detected.

FEATURES
● 8 voltage settings: 240Vac, 2kV, 6kV, 11kV,
22kV, 33kV, 132kV, and 275kV
● Bright LED visual indication
● Frequency range: 40~70Hz
● Audio indication
● Easy-to-prove method
● Self-test selection
● Uses 1.5V “C” × 3 battery
● High impact nylon casing
● Non-contact detection by proximity
● Compatible with most link sticks
● Lightweight, robust, & compact
● Suitable for indoor and outdoor use
● Also detects low voltage on any system
● Easy access to batteries
● No special parts needed
● Case height: 255mm / Case width: 96mm
● Meets EN 61326-1 CISPR 11
EN 61000-4-2 EN 61000-4-3
● United States Design Patent: US D474, 705 S
● Special voltage ranges available upon request
● The maximum detection range can be 500kV

Expected test results (Laboratory testing):
Range Operated from
240V Variable from 80V or depending
on the type of source
2kV 250V
6kV 500V
11kV 1000V
22kV 1500V
33kV 4000V
132kV 8000V
275kV 22kV

Model
Code Range
275kV01 OFF–TEST–240V–2kV–6kV–11kV–22kV–33kV–132kV–275kV
275kV02 OFF–TEST–240V–3.3kV–6.6kV–11kV–22kV–33kV–66kV–132kV–275kV
275kV03 OFF–TEST–240V–11kV–22kV–33kV–66kV–110kV–132kV–210kV–275kV
275kV04 OFF–TEST–240V–2.3kV–6kV–11kV–22kV–33kV–132kV–275kV
275kV05 OFF–TEST–240V–2kV–6kV–11kV–22kV–33kV–132kV–230kV–275kV
500kV01 OFF–TEST–240V–3.3kV–11kV–22kV–33kV–66kV–110kV–220kV–330kV–500kV
500kV02 OFF–TEST–240V–4.2kV–15kV–69kV–115kV–230kV–345kV–500kV
500kV03 OFF–TEST–240V–69kV–115kV–138kV–230kV–500kV
500kV04 OFF–TEST–230V–3kV–6kV–10kV–35kV–66kV–110kV–220kV–330kV–500kV
500kV05 OFF–TEST–240V–4.2kV–35kV–69kV–115kV–230kV–345kV–500kV
500kV06 OFF–TEST–400V–15kV–24kV–110kV–220kV–500kV
500kV07 OFF–TEST–240V–4.2kV–15kV–69kV–138kV–230kV–345kV–500kV
230kV01 OFF–TEST–240V–69kV–115kV–138kV–230kV
230kV02 OFF–TEST–240V–4.2kV–15kV–25kV–35kV–69kV–115kV–230kV
220kV01 OFF–TEST–240V–3.3kV–6.6kV–11kV–22kV–33kV–66kV–110kV–220kV
220kV02 OFF–TEST–0.22kV–6kV–10kV–35kV–110kV–220kV
220kV03 OFF–TEST–1kV–3.3kV–6.6kV–11kV–22kV–33kV–66kV–132kV–220kV
220kV04 OFF–TEST–240V–11kV–33kV–132kV–330kV
33kV01 OFF–TEST–33kV
11kV01 OFF–TEST–11kV
115kV01 OFF–TEST–240V–11kV–15kV–34.5kV–69kV–115kV