Patient Monitor MD9012 Meditech

Patient Monitor MD9012 Meditech

Patient Monitor MD9012 Meditech is 12 inch TFT display high resolution. Automatic temperature drift treatment of NIBP measuring patented technology;Friendly and configurable user interface;Powerful data review:Maximum 720-hour graphic and tabular trends, Up to10000 pieces of NIBP record storage, Wired or wireless networkable with Central Monitoring System;On-line upgrading keeps you updated.

Features:

  • High resolution 12” color TFT display
  • 12 Channel waves.9 Parameters : ECG, Resp, NIBP, SpO2, TEMP,
  • Light weight, compact and portable
  • Built-in rechargeable lithium battery
  • Unique human voice alarm
  • Rich screen layouts: Standard, Big font, Trend table, NIBP trend, ECG full lead, OxyCRG, IoC Layout
  • Powerful storage: Maximum 720 Hour graphic and tabular trends of all
  • parameters, up to 10000 NIBP review, 200 alarm review ,2 Hours of all wave forms
  • System software can be upgraded through network
  • Data and waveforms color be adjustable
  • Arrhythmia analysis and S-T segment analysis
  • Suitable for adult, pediatric and neonatal patient
Options:
  • Invasive Blood Pressure (IBP)
  • Carbon dioxide (CO2) Module
  • Thermal Printer
  • Touch Screen

Specification:

ECG Lead Mode 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V) Lead selection I, II, III, avR, avL, avF, V, Waveform 2 ch Lead mode 3 Leads ( R, L, F or RA, LA, LL) Lead selection I, II, III, Waveform 1 ch Gain x2.5mm/mV, x5.0mm/mV, x10mm/mV, x20mm/mV, auto HR and Alarm Range Adult 15 ~ 300 bpm Neo/Ped 15 ~ 350 bpm Accuracy ± 1% or ± 1bpm,which great Resolution 1 bpm Sensitivity > 200 (uV ) Differential Input Impedance > 5 MΩ CMRR Monitor > 105 dB Operation > 105 dB Diagnosis > 85 dB Electrode offset potential ±300mV Leakage Current < 10 uA Baseline Recovery < 3 S After Defi. ECG Signal Range ±8 m V ( Vp-p ) Bandwidth Surgery 1 ~ 15 Hz Monitor 0.5 ~ 35 Hz Diagnostic 0.05 ~ 100 Hz Calibration Signal 1 (mV ), Accuracy :±5% ST Segment Monitoring Range Measure and Alarm -2.0 ~ +2.0 mV ARR Detecting Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY,MISSED BEATS, PNP, PNC Alarm Available Review Available RESPIRATION Method Impedance between R-F(RA-LL) Differential Input Impedance >2.5 MΩ Measuring Impedance Range: 0.3~5.0Ω Base line Impedance Range: 0 – 2.5 KΩ Bandwidth 0.3 ~ 2.5 Hz Resp. Rate Measuring and Alarm Range Adult 0 ~ 120 rpm Neo/Ped 0 ~ 150 rpm Resolution 1 rpm Accuracy ±2 rpm Apean Alarm 10 ~ 40 S NIBP Method Oscillometric Mode Manual, Auto, STAT Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min) Measuring Period in STAT Mode 5 Min Pulse Rate Range 40 ~ 240 bpm Alarm Type SYS, DIA, MEAN Measuring and alarm range Adult Mode SYS 40 ~ 270 mmHg DIA 10 ~ 215 mmHg MEAN 20 ~ 235 mmHg Pediatric Mode SYS 40 ~ 200 mmHg DIA 10 ~ 150 mmHg MEAN 20 ~ 165 mmHg Neonatal Mode SYS 40 ~ 135 mmHg DIA 10 ~ 100 mmHg MEAN 20 ~ 110 mmHg Resolution Pressure 1mmHg Accuracy Pressure Maximum Mean error ±5mmHg Maximum Standard deviation ±8mmHg Overpressure Protection Adult Mode 297±3 mmHg Pediatric Mode 240±3 mmHg Neonatal Mode 147±3 mmHg SpO2 Measuring Range 0 ~ 100 % Alarm Range 0 ~ 100 % Resolution 1 % Accuracy 70% ~ 100% ±2 % 0% ~ 69% unspecified Actualization interval about 1 Sec. Alarm Delay 10 Sec. Pulse Rate Measuring and Alarm Range 0~254bpm Resolution 1bpm Accuracy ±2bpm TEMPERATURE Channel 1 Measuring and Alarm Range 0 ~ 50 C Resolution 0.1~C Accuracy ±0.1~C Actualization interval about 1 Sec. Average Time Constant < 10 Sec. IBP Label ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measuring and alarm range ART 0 ~ 300 mmHg PA -6 ~ 120 mmHg CVP/RAP/LAP/ICP -10 ~ 40 mmHg P1/P2 -10 ~ 300 mmHg Press Sensor Sensitivity 5 uV/V/mmHg Impedance 300-3000Ω Resolution 1 mmHg Accuracy ±2% or ±1mmHg, which great about 1 Sec.  

Touch Screen Patient Monitor BT-770

Touch Screen Patient Monitor BT-770

Touch Screen Patient Monitor BT-770 is one of the best Multi-Parameter Touch Screen Patient Monitor made by Bistos Medical Korea, the Quality is absolutely phenomenal and the feedback of these monitors are absolutely Good. 12.1 Inches Touch Screen allows it's user to operate and understand the parameters without any hitch. The Specification of Touch Screen Patient Monitor BT-770 is mentioned below, For more information regarding the questions, queries, prices please feel free to contact us at +923224602203 pr Email: zirarenterprises@gmail.com, info@zirarenterprises.com

Features:

  • 12.1“color TFT touch screen
  • ECG, Resp., SpO2, NlBP,Temp., CO2, IBP, Multi—gas, C.O., Masimo SpO
  • Precise ECG measurement with pacemaker detection
  • ST segment and 16 types of arrhythmia analysis
  • Double over-pressure protection for NIBP
  • Intelligent cuff inflation pressure adjustment
  • Smart Hook/Stand design, provide multiple placement modes
  • Plug & Play Modular IBP& C.O., Modular Printer
  • Multiple configuration options: 4-channel IBP, CO , invasive C.O., Multi-gas
  • Over 5 hours continuous working on battery
  • 12-1IV wide range DC input, suitable for ambulance
  • Capable to connect with central monitoring system
  • HL7 export to clinical information systems (UP TO MAX 30) Option for WIFI
Click below to Download the Catalog of Touch Screen Patient Monitor BT-770 Bistos Patient Monitor(BT-710 720 740 750 770 780) (1).pdf

Click to see our full range of Patient Monitor and Multi Parameter Monitors

General Information:

Touch Screen Patient Monitor BT-770 is Multi-parameter Patient Monitor by Bistos provides various patient vital signs such as pulse rate, ECG, respiration, blood oxygen saturation, blood pressure and temperature by placing or inserting the various sensors to the appropriate site of patient. The device is composed with display, control circuit and panel, and input part for various sensors. Touch Screen Patient Monitor BT-770 detects ECG, SpO2, NIBP, etc. using ECG cable and specific probes and sensors. The detected analog signal amplifies and converted to digital. This concerted data feed to the CPU and converted to the display format as number and waveform. This device is incorporated with alarm system. The alarm generated when the detected signal range is beyond the user set alarm limits.