Due to surge in Dollar Rate, kindly contact us to confirm current pricing, thanks.

ANESTHESIA MACHINE WITH VENTILATOR – NSL-GE-800 PLUS USA

ANESTHESIA MACHINE WITH VENTILATOR – NSL-GE-800 PLUS USA

ANESTHESIA MACHINE WITH VENTILATOR – NSL-GE-800 PLUS USA. The GE Series of Anesthesia machines are a robust feat of engineering with heavy duty alloy frame and state-of-the-art design that ensures surgeons have one thing less to worry about during their work.

The compact design keeps the unit footprint to a minimal while providing all the features and technology found in most premium grade Anesthesia Machines today.

please click here to download the product catalog anesthesia machine MDX china.pdf

  • Special Feature:
    Application: Adult, Pediatric
  • Driven mode: Pneumatically driven electronically controlled
  • Mode: Semi-open, Semi-closed or closed system
  • Anesthetic vaporizer: One vaporizer (optional two)

Anesthesia Ventilator

  • Display: High light LED display
    Ventilation Volume: 50~1600ml
  • Breath frequency: 1~90BPM
  • I:E ratio: 4:1 ~ 1:6
  • Monitor parameter: Tidal volume, breath frequency, MV
  • Alarm: MV high alarm, MV low alarm, TV high alarm, TV low alarm

Main Unit

  • Circle absorber: Compact circle absorber
  • Bellow: 0 ~ 1600ml
  • Oxygen FLUSH: 25L/min ~ 75L/min

Flow meter:

  • O2, N2O two-tube flowmeter
  • O2 tube: 0L/min ~ 10L/min
  • N2O tube: 0L/min ~ 10L/min
  • O2 and N2O linkage device Adjust O2 and N2O in proportion ( keep O2 concentration not lower than 25% )

Gas source pressure:

  • O2: 0.25 ~ 0.65Mpa
  • N2O: 0.25~ 0.65Mpa
  • Gauge: 2 units, one N2O, one O2

Description

ANESTHESIA MACHINE WITH VENTILATOR – NSL-GE-800 PLUS USA

ANESTHESIA MACHINE WITH VENTILATOR – NSL-GE-800 PLUS USA. The GE Series of Anesthesia machines are a robust feat of engineering with heavy duty alloy frame and state-of-the-art design that ensures surgeons have one thing less to worry about during their work.

The compact design keeps the unit footprint to a minimal while providing all the features and technology found in most premium grade Anesthesia Machines today.

please click here to download the product catalog anesthesia machine MDX china.pdf

  • Special Feature:
    Application: Adult, Pediatric
  • Driven mode: Pneumatically driven electronically controlled
  • Mode: Semi-open, Semi-closed or closed system
  • Anesthetic vaporizer: One vaporizer (optional two)

Anesthesia Ventilator

  • Display: High light LED display
    Ventilation Volume: 50~1600ml
  • Breath frequency: 1~90BPM
  • I:E ratio: 4:1 ~ 1:6
  • Monitor parameter: Tidal volume, breath frequency, MV
  • Alarm: MV high alarm, MV low alarm, TV high alarm, TV low alarm

Main Unit

  • Circle absorber: Compact circle absorber
  • Bellow: 0 ~ 1600ml
  • Oxygen FLUSH: 25L/min ~ 75L/min

Flow meter:

  • O2, N2O two-tube flowmeter
  • O2 tube: 0L/min ~ 10L/min
  • N2O tube: 0L/min ~ 10L/min
  • O2 and N2O linkage device Adjust O2 and N2O in proportion ( keep O2 concentration not lower than 25% )

Gas source pressure:

  • O2: 0.25 ~ 0.65Mpa
  • N2O: 0.25~ 0.65Mpa
  • Gauge: 2 units, one N2O, one O2

There are no reviews yet.