Cubix ECG/EKG Holter Machine MDX USA
Cubix ECG/EKG Holter Machine MDX USA
Cubix ECG/EKG Holter Machine MDX USA is a state-of-the-art holter device to measure patients EKG signals constantly throughout their day without being a discomfort due to its compact size. An event marker button allows a patient to mark the time when he or she feels cardiac distress allowing doctors to easily find data according to the event market time.
The Cubix holter is a must have portable device for any cardiologist to do a complete and thorough diagnosis of patients. Please click to download the full catalog Cubix™ Holter ECG.pdf or visit the manufacturers website
Cubix ECG/EKG Holter Machine MDX USA
Recorder Features
■ With advanced design and technology, the recorder can work stably, dependable and is durable.
■ Be provided with the capability of anti-jamming and shock-pro.
■ Small volume with OLED screen. The resolution is 160*128.
■ Be provided with functions of waveform preview, record review and event marking.
■Accurate record of the start time of the data sampled owing to the real time clock of itself.
■Avoid damage owing to the repeating inserting and pulling out by using the inbuilt TF card to storage the data.
■The maximum capability can be 2GB, so the original data can be saved perfectly by no compression.
■The average review time of single case can be less than 40 seconds by using interface of USB 2.0.
■Record waveform details inextenso by the design of high precision and sampling frequency.
■Record the state of pacemaker exactly by higher sampling frequency.
The features of software
■Quick and accurate analysis system.
■With 3 leads synchro analysis, QRS search can be more exactly.
■ There are more than 10 templates as atrial premature beat module, ventricular premature beat module, long interval module, atrial flutter module, atrial fibrillation module etc. and multiplicate User-defined templates could almost identify every kind of pathologic waveforms.
■Optional main channel.
■ Agile and exact “Atrial Fibrillation” analysis.
■The function of pacing analysis could analyse all pacemakers.
■ Many pacine modules have been added.
■ Any period of single lead or 3-leads ECG can be reviewed at any time with the function of fast waveform review and analysis.
■ The types of the analysis system of HR variability include five minutes of short ECG and one hour or 24-hour of long ECG.
■ Print report expediently.
■ Perfect function of case management.
■ With the function of ST segment analysis and general load of the disorder of the heart muscle, the physician can judge a disease or disorder of the heart muscle generally.
■”Sleep breath pause syndrome analysis”, the physician could print sleep asphyxia analysis report and diagnose.
■”HRT” analysis, when the adjustable function is natural, this transitory change will be represented by the form of HRT immediately.
■15.”T Wave Alternation” analysis is a important index on judging and preventing arrhythmia.
Standards
- Number of channels: 3 channels;
- Sampling rate: 10000Hz;
- Sampling accuracy:12bit;
- Recording time : 24 h;
- Power: 2 batteries in size 5;
- Interface: USB2.0;
- Scale voltage:1mV±5%;
- Standard Sensitivity:10mm/mV±5%;
- Noise level:≤30μV;
- CMRR:≥60dB;
- Feathers of low frequency : Time constant>3.2s;
- Scan speed:25mm/s±5%;
- Enduring polarization voltage:±300mV;
- Least measure signal : 50 µV p-p;
Cubix ECG/EKG Holter Machine MDX USA
Cubix ECG/EKG Holter Machine MDX USA is a state-of-the-art holter device to measure patients EKG signals constantly throughout their day without being a discomfort due to its compact size. An event marker button allows a patient to mark the time when he or she feels cardiac distress allowing doctors to easily find data according to the event market time.
The Cubix holter is a must have portable device for any cardiologist to do a complete and thorough diagnosis of patients. Please click to download the full catalog Cubix™ Holter ECG.pdf or visit the manufacturers website
Cubix ECG/EKG Holter Machine MDX USA
Recorder Features
■ With advanced design and technology, the recorder can work stably, dependable and is durable.
■ Be provided with the capability of anti-jamming and shock-pro.
■ Small volume with OLED screen. The resolution is 160*128.
■ Be provided with functions of waveform preview, record review and event marking.
■Accurate record of the start time of the data sampled owing to the real time clock of itself.
■Avoid damage owing to the repeating inserting and pulling out by using the inbuilt TF card to storage the data.
■The maximum capability can be 2GB, so the original data can be saved perfectly by no compression.
■The average review time of single case can be less than 40 seconds by using interface of USB 2.0.
■Record waveform details inextenso by the design of high precision and sampling frequency.
■Record the state of pacemaker exactly by higher sampling frequency.
The features of software
■Quick and accurate analysis system.
■With 3 leads synchro analysis, QRS search can be more exactly.
■ There are more than 10 templates as atrial premature beat module, ventricular premature beat module, long interval module, atrial flutter module, atrial fibrillation module etc. and multiplicate User-defined templates could almost identify every kind of pathologic waveforms.
■Optional main channel.
■ Agile and exact “Atrial Fibrillation” analysis.
■The function of pacing analysis could analyse all pacemakers.
■ Many pacine modules have been added.
■ Any period of single lead or 3-leads ECG can be reviewed at any time with the function of fast waveform review and analysis.
■ The types of the analysis system of HR variability include five minutes of short ECG and one hour or 24-hour of long ECG.
■ Print report expediently.
■ Perfect function of case management.
■ With the function of ST segment analysis and general load of the disorder of the heart muscle, the physician can judge a disease or disorder of the heart muscle generally.
■”Sleep breath pause syndrome analysis”, the physician could print sleep asphyxia analysis report and diagnose.
■”HRT” analysis, when the adjustable function is natural, this transitory change will be represented by the form of HRT immediately.
■15.”T Wave Alternation” analysis is a important index on judging and preventing arrhythmia.
Standards
- Number of channels: 3 channels;
- Sampling rate: 10000Hz;
- Sampling accuracy:12bit;
- Recording time : 24 h;
- Power: 2 batteries in size 5;
- Interface: USB2.0;
- Scale voltage:1mV±5%;
- Standard Sensitivity:10mm/mV±5%;
- Noise level:≤30μV;
- CMRR:≥60dB;
- Feathers of low frequency : Time constant>3.2s;
- Scan speed:25mm/s±5%;
- Enduring polarization voltage:±300mV;
- Least measure signal : 50 µV p-p;
You must be logged in to post a review.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
Autoclave Double Drum 30 LBS Pakistan
Autoclave Double Drum 30 LBS Pakistan
Autoclave Double Drum 30 LBS Pakistan is a best featured and manufactured product by Zirar Enterprises, We are one of the top leading manufacturer and distributor of autoclaves in Pakistan. We are manufacturing top-notch sterilizers and autoclaves in Pakistan. As we are the manufacturer of autoclaves so we can build or modify autoclaves according to your needs. Why Autoclave? or Autoclave Double Drum 30 LBS Pakistan Autoclave provides a physical method for sterilization in order to kill bacteria, microorganisms and spores. They are used to decontaminate certain biological waste and sterilize media, instruments and lab ware also it is highly recommended to sterilize medical instrument before disposing it off. Autoclave Double Drum 30 LBS Pakistan and Accessories Zirar Enterprises not only stops at autoclaves but we are also providing wide range of accessories to use before handling autoclaves for e.g. (Lab Coats, Safety Goggles, Safety Gloves and Shoes). Types of Autoclaves for Sale in Pakistan- Horizontal Autoclaves & sterilizers
- Vertical Autoclaves & sterilizers
- Electrical and Gas Autoclaves
- Fully SS (stainless steel autoclaves)
- MS & SS autoclaves
- Capacity: Auto clave 100L (16x30) Horizontal
- Drum: Double chamber (Jacket & Chamber)
- Material: MS Mild steel and SS Stainless steel (SS sheet size 2.5 MM for double chamber and 1.5 for single chamber)
- Working pressure: 30 – 35 pound (can be used up to 50-pound pressure if needed)
- Power: Electric 3 phase + Gas
- Wika Gauges: Water pressure gauge, steam pressure gauge and chamber pressure gauge.
- Valves: Safety valves & emergency steam release valves.
Patient Monitor Accuit Sign 8 MDX-USA
Patient Monitor Accuit Sign 8 MDX-USA
Patient Monitor Accuit Sign 8 MDX-USA is one of the best patient monitor equivalent to any other renowned brand, MDX USA has made it with sophisticated technology which makes Patient Monitor Accuit Sign 8 MDX-USA standing top quality patient monitor. please click here to download the product catalog Accuit Sign™ 8.pdf Feature:- High resolution 12.1"color TFT display
- Suitable for adult, pediatric and neonatal patient
- Color TFT Screen, waveform up to 8 channels
- Operation modes: Diagnostic, Monitor, Surgery
- Light and portable with Built-in rechargeable lithium battery
- UP to 10 kinds of monitor parameters
- Arrhythmia analysis, pace-marker detection and S-T Segment analysis
- 72 hour storage and review of trend grams and tables
- 500 NIBP measurement date can be storage and recall
- Electro surgical unit and defibrillation protected
- Networkable with central monitoring system
- 5-lead or 3-lead selectable
- Input: 5-lead :RA; LA; RL; LL; V or R; L; N; F; C
- ECG waveforms of 7-leads display on the same screen
- Lead selection :I; II; III; avR; avL; avF; Vx
- ECG waveform :2 channels
- Gain selection :12.5mm/s, 25mm/s, 50mm/s
- Accuracy :±1bpm or ±1%, whichever is greater
- Protection :Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation
- Calibration signal :1mV±5%
- Alarm range: Adult :15-300bpm
- Pediatric/Neonatal :15-350bpm
- Arrhythmia analysis and S-T segment analysis
- S-T segment detection Measurement rang :-0.2mv~2.0mv
- Alarm :Yes, audible and visual alarm, alarm events review
- Operation modes :Manual/Automatic/STAT
- Measurement unit :mmHg/KPa selectable
- Measurement types :Systolic, Diastolic and Mean
- Over-pressure protection :YES
- Resolution :1mmHg
- Accuracy :Mean error and standard deviation per ANSI/AAMI SP-10
- Alarm :Systolic, Diastolic, and Mean
- Auto measure time :Adjustable
- Measurement rang :10-270mmHg
- 500 NIBP measurement date can be storage and recall
- Measurement range :0-100%
- Accuracy :70-100%, ±2% 0-69%, upspecified
- Alarm range :0-100% Pulse rate
- Range :20-254bpm
- Accuracy :±3bpm
- Respiration
- Method :RA-LL impedance
- Pediatric/Neonatal :6-150rpm
- Alarm range: Adult :6-120rpm
- Pediatric/Neonatal :6-120rpm
- Apnea alarm :YES
- Channel :Dual-channel
- Alarm range :0-50℃
- Apnea :0.1℃
Urine Analyzer BA600
Urine Analyzer BA600
Urine Analyzer BA600 is one the best urine analyzer for conducting urine tests for diagnostic purposes. The Urine Analyzer BA600 has a capability to give streamline analysis of cultural urine test. The weight of the Urine Analyzer BA600 is 2.5 Kilo-gram which enables paramedic staff and laboratory staff to carry it easily and the machine becomes almost portable with ease of maneuver. For more information please feel free to contact us at +92-322-4602203 Email: zirarenterprises@gmail.com, info@zirarenterprises.comFeatures:
- 5-inch touch screen
- 11 testing parameters
- 100 samples/hour throughput
- Dual wavelength reflectance test method
- Auto & manual test mode
- Thermal printer, auto & manual print
- Support LIS and barcode
- Less and easy maintenance
- Per test cost Rs:15/- PKR
- Principle: Dual wavelength reflectance method
- Wavelength: 520nm, 640nm, 660nm
- Parameters: Glucose, Bilirubin, Ketone, Specific Gravity, Blood, pH, Protein, Urobilinogen, Nitrite, Leukocyte, Vitamin C
- Throughput: 100 samples/hour
- Sample type: Urine
- Test mode: Auto, manual
- Waiting time: 15-40s
- Display: 5 Inch touch screen
- Memory: 2,000 results storage
- Language: English
- Strip: Original GENIUS strip, 100 strips per bottle
- Report format: Semi-quantitative and qualitative
- Coincidence rate: ≥90%
- Relative humidity: ≤70%
- Size: 360mm×225mm×160mm
- Net weight: 2.5kg
- Display: 5-inch screen
- Power supply: AC 100-240V 50/60Hz
- Working temperature: 10-30°C
- Atmospheric pressure: 86.0kPa-106.0kPa

Reviews
There are no reviews yet.