Defibrillator Defi Xpress Meditech
Defibrillator Defi Xpress Meditech
Defibrillator Defi Xpress Meditech is defibrillator device with voice alarm which can meet your clinical needs from Basic Life Support (BLS) to Advanced Cardiac Life Support (ACLS). Defibrillators benefit patients who experience a sudden case of heartbeat is arrhythmias. In these instances
Defibrillators are an important tool for anyone in the vicinity of a victim suffering from ventricular arrhythmia as well. arrhythmia renders the patient unconscious. the heart may beat too fast, too slow or an irregular mix of both. The anticipated outcome of sucharrhythmias is either cardiac arrest or a stroke.
Product Features:
Display
Screen Type: High-resolution display
Screen Size: 7 inches (17.7 cm) diagonally
Sweep Speed: 25mm/sec
Information: Heart Rate . Lead/Pads. Alarm . On/Off . SpO2 . AED
Functions and Prompts Alarm Selection and Limits Delivered Energy.
5 Languages available: English.Russian.Spanesh.Chinese.Turkish
Defibrillator
Waveform: Biphasic
Charge Time: Less than 7 seconds with a new fully charged battery.
Energy Display: Monitor display indicates both selected and delivered energy.
Charge Prompt Type: Voice and visual prompts.
Electrode Impedance Measurement Range: 0-250 ohms.
ECG Monitoring
Patient Connection: 3-lead ECG cable or 5-lead ECG cable paddles.
Lead Selection: Displayed on monitor paddles I II III AVR AVL AVF V.
ECG Size: 0.25 0.5 1 1.5 2 4 cm/mV display on monitor.
Heart Rate: 20-300BPM.
Heart Rate Alarm: On/Off displayed on monitor user-selectable.
Smart Alarms: Beeper/voice prompts indicate shock able rhythm.
Battery
Type: Rechargeable Ni-MH battery 12V.
Operating time: For a new fully charged battery: 60 defibrillator discharges at maximum energy or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions.
SpO2 Module (Options):
Measurement Range: 30~100% ±2% between 80%~90% others ±5%
Alarm Range: User set high limit and low limit.
Alarm Accuracy: ±10% within setting values.
Alarm time Accuracy: less than 12 sec.
1-Meditech Pulse Oximeter
2-Nellcor Pulse Oximeter
Recorder
Paper: 50mm thermal.
Speed: 12.5mm/sec 25mm/sec 50mm/sec. User-selectable 6-second delay.
Printing Method: High-resolution thermal print head.
Print-out Modes: Manual or automatic user-configurable.
On/Off Control: Front panel and paddle.
Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge.
AED Mode
AED Function: Auto analyze and charge x3 with programmable auto energy level selection screen prompts and voice prompts.
Shockable Rhythms: Ventricular fibrillation with amplitude >=200uV ventricular tachycardia with rates >=140bpm and QRS complex wave duration >=140ms.
Charge Control: Control on device front panel press key on paddle.
Prompts: Voice and visual prompts.
Manual Mode
Energy Selection: Selectable at 2 5 7 10 20 30 50 70 100 150 200 300 360 joules.
Synchronized Mode: Synchronizes defibrillator pulse to patient’s
R-wave. “SYNC” message displayed on monitor.
Technical Specification:
The Specification of physical electronic isolation defibrillator battery electromagnetic compatibility and rhythm recognition performance will be described in this section:
Data Acquisition and Analysis
The DEFI XPRESS is no longer automatically configured to a certain frequency response. There are two diagnostic frequency options: 0.05-150 Hz
Diagnostic Frequency Filter and 0.05-40 Hz Filtered Diagnostic
Frequency filter. See chapters 7 on switching between these two options.
Defibrillator
Waveform Details:
The tables below provide details of the waveforms delivered by the DEFI XPRESS when connected to resistive loads of 25 50 and 100 Ohms and set to its maximum output. The waveforms are characterized by DEFI XPRESS values for peak current (Ip) for biphasic: duration of The first output phase (tphase1) and duration of the second output phase (tphase2). The values shown are within 10%.
Waveform: Truncated Exponential Biphasic
Output Energy Accuracy:
+/- 10% or 1J (whichever is greater) at 50 ohms
+/- 15% or 1J (whichever is greater) at 25 to 100 ohms
Energy Select:
External: 2 5 7 10 20 30 50 70 100 150 200 300 360 J.
Charge Time:
< 12 seconds @ 360 J (with a Ni-MH 12 volt – MEDITECH battery after15discharges).
< 15 seconds @ 360 J (no battery 90% AC mains voltage)
Charge Indicator: Audible and graphic.
Output :
Adult paddles pediatric adapter and multipurpose hands-free adapter available.
Synchronizer: Delivers energy within 60 msec.
Disarm: Front panel switch.
Monitor/Display
Input:
3-lead 5-lead patient cable
Size: 7 inches (16.5 cm) diagonal non-fade.
Type: color (TFT)
Display Resolution: 800 x 600 pixels.
Sweep Speed: 12.5mm/s25mm/s50mm/s
Lead Selections: I II III AVR AVL AVF V.
Frequency Response: (User-selectable).
0.7 to 20 Hz operation mode
0.3 to 40 Hz Monitoring mode
0.05 to 150 Hz Analysis mode
0.5 to 30 Hz AED mode
Common Mode Rejection:>=60dB
Heart Rate Meter: 20 to 300 BPM.
Heart Rate Alarms: User-selectable.
Size: 0.125 0.25 0.5 1 2 4 cm/mv and auto-ranging.
ECG Output: 1 V/mV.
Heart Rate Response to Irregular Rhythm: (AAMI EC13-1992 section 4.1.2.1.e.)
Alarms
Heart Rate Spo2 Alarm:
Audible: 5 pulse 800 tone with a PW of 150 msec a PRI of 225 msec and a repetition interval of 10 seconds.
Visual: Heart Rate Alarm causes the displayed heart rate to flash at 2 Hz. This display is located at the top of the display and is 0.4″ high and 0.28 to 0.840″ wide depending on num-ber of digits in the heart rate. Is amber black white or whatever the color the display text is.
Lead Fault Alarm:
Audible: 3 pulse 500 Hz triplet tone with a PW of 200 msec a PRI of 310 msec. When the HR alarm is set or the pacer is on the lead fault tone repeats at a repetition interval of 20 seconds.
Visual: Lead Fault condition causes a “LEAD FAULT” message to be displayed on the trace along with a dashed line the width of the trace. The text is 0.18″ high and is the color of the display text. The dashed line is 5″ Long the width of the display. The signal is not modulated.
Physiological Alarms (Spo2):
Audible: See Heart Rate Alarm
Visual: Physiological alarms cause the displayed parameter to flash at 2 Hz. Color is amber white or the same as the display colored text.
Mute Duration: 90 seconds.
Recorder
Type: High-resolution thermal array.
Annotation: Time date ECG lead ECG gain heart rate defibrillation and treatment summary ACLS events.
Paper Width: 50 mm.
Paper Speed: 25 mm/sec 50 mm/sec 12 Lead 50 mm/sec
Delay: 6 seconds.
Frequency Response:
Automatically set to monitor’s frequency response.
Battery
High Capacity Type: Ni-MH 12V volt – MEDITECH
Up to 4 hours ECG monitoring or 110 full-energy dis-charges or 3 hours combined ECG Spo2 and monitor-ing
Proper battery care is required to maintain maximum avail-able capacity.
Low Battery Indicator:
Flashing low battery icon on display and flashing LED on front panel..
Recharge Rate: 80% in 7.5 hours. 100% in 9 hours.
General
Weight: 10 pounds (4.95 kg) (basic configuration).
Size: 13 x 12.5 x 5.3 inches (33 x 31.8 x 13.5 cm).
Operating:
Temperature*: 0 to 45° C
Humidity* (NC): 15 to 95% RH (30 to 90% with CO2 probe)
Vibration*: MIL-STD 810E
Shock / Drop*: MIL-STD 810E
Altitude: Up to 4572 M (15000 feet)
Transport and Storage:
Temperature: -30 to 70°C (-20 to 70°C with CO2 probe)
Humidity: 15 to 95% RH (non-condensing)
Atmospheric pressure: 860 to 1060 hPa
Shock/vibration: ISTA 1A
Enclosure Protection*:
Solid Foreign object: IEC 529 IP2X
Water: IEC 529 IPX4.
All tests performed per AAMI DF-2 Defibrillation Standard.
Operating Power:
Ni-MH 12 volt – MEDITECH
SAED Rhythm Recognition Performance
The DEFI XPRESS SAED algorithm exceeds the requirements of ANSI/AAMI
Defibrillator Defi Xpress Meditech
Defibrillator Defi Xpress Meditech is defibrillator device with voice alarm which can meet your clinical needs from Basic Life Support (BLS) to Advanced Cardiac Life Support (ACLS). Defibrillators benefit patients who experience a sudden case of heartbeat is arrhythmias. In these instances
Defibrillators are an important tool for anyone in the vicinity of a victim suffering from ventricular arrhythmia as well. arrhythmia renders the patient unconscious. the heart may beat too fast, too slow or an irregular mix of both. The anticipated outcome of sucharrhythmias is either cardiac arrest or a stroke.
Product Features:
Display
Screen Type: High-resolution display
Screen Size: 7 inches (17.7 cm) diagonally
Sweep Speed: 25mm/sec
Information: Heart Rate . Lead/Pads. Alarm . On/Off . SpO2 . AED
Functions and Prompts Alarm Selection and Limits Delivered Energy.
5 Languages available: English.Russian.Spanesh.Chinese.Turkish
Defibrillator
Waveform: Biphasic
Charge Time: Less than 7 seconds with a new fully charged battery.
Energy Display: Monitor display indicates both selected and delivered energy.
Charge Prompt Type: Voice and visual prompts.
Electrode Impedance Measurement Range: 0-250 ohms.
ECG Monitoring
Patient Connection: 3-lead ECG cable or 5-lead ECG cable paddles.
Lead Selection: Displayed on monitor paddles I II III AVR AVL AVF V.
ECG Size: 0.25 0.5 1 1.5 2 4 cm/mV display on monitor.
Heart Rate: 20-300BPM.
Heart Rate Alarm: On/Off displayed on monitor user-selectable.
Smart Alarms: Beeper/voice prompts indicate shock able rhythm.
Battery
Type: Rechargeable Ni-MH battery 12V.
Operating time: For a new fully charged battery: 60 defibrillator discharges at maximum energy or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions.
SpO2 Module (Options):
Measurement Range: 30~100% ±2% between 80%~90% others ±5%
Alarm Range: User set high limit and low limit.
Alarm Accuracy: ±10% within setting values.
Alarm time Accuracy: less than 12 sec.
1-Meditech Pulse Oximeter
2-Nellcor Pulse Oximeter
Recorder
Paper: 50mm thermal.
Speed: 12.5mm/sec 25mm/sec 50mm/sec. User-selectable 6-second delay.
Printing Method: High-resolution thermal print head.
Print-out Modes: Manual or automatic user-configurable.
On/Off Control: Front panel and paddle.
Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge.
AED Mode
AED Function: Auto analyze and charge x3 with programmable auto energy level selection screen prompts and voice prompts.
Shockable Rhythms: Ventricular fibrillation with amplitude >=200uV ventricular tachycardia with rates >=140bpm and QRS complex wave duration >=140ms.
Charge Control: Control on device front panel press key on paddle.
Prompts: Voice and visual prompts.
Manual Mode
Energy Selection: Selectable at 2 5 7 10 20 30 50 70 100 150 200 300 360 joules.
Synchronized Mode: Synchronizes defibrillator pulse to patient’s
R-wave. “SYNC” message displayed on monitor.
Technical Specification:
The Specification of physical electronic isolation defibrillator battery electromagnetic compatibility and rhythm recognition performance will be described in this section:
Data Acquisition and Analysis
The DEFI XPRESS is no longer automatically configured to a certain frequency response. There are two diagnostic frequency options: 0.05-150 Hz
Diagnostic Frequency Filter and 0.05-40 Hz Filtered Diagnostic
Frequency filter. See chapters 7 on switching between these two options.
Defibrillator
Waveform Details:
The tables below provide details of the waveforms delivered by the DEFI XPRESS when connected to resistive loads of 25 50 and 100 Ohms and set to its maximum output. The waveforms are characterized by DEFI XPRESS values for peak current (Ip) for biphasic: duration of The first output phase (tphase1) and duration of the second output phase (tphase2). The values shown are within 10%.
Waveform: Truncated Exponential Biphasic
Output Energy Accuracy:
+/- 10% or 1J (whichever is greater) at 50 ohms
+/- 15% or 1J (whichever is greater) at 25 to 100 ohms
Energy Select:
External: 2 5 7 10 20 30 50 70 100 150 200 300 360 J.
Charge Time:
< 12 seconds @ 360 J (with a Ni-MH 12 volt – MEDITECH battery after15discharges).
< 15 seconds @ 360 J (no battery 90% AC mains voltage)
Charge Indicator: Audible and graphic.
Output :
Adult paddles pediatric adapter and multipurpose hands-free adapter available.
Synchronizer: Delivers energy within 60 msec.
Disarm: Front panel switch.
Monitor/Display
Input:
3-lead 5-lead patient cable
Size: 7 inches (16.5 cm) diagonal non-fade.
Type: color (TFT)
Display Resolution: 800 x 600 pixels.
Sweep Speed: 12.5mm/s25mm/s50mm/s
Lead Selections: I II III AVR AVL AVF V.
Frequency Response: (User-selectable).
0.7 to 20 Hz operation mode
0.3 to 40 Hz Monitoring mode
0.05 to 150 Hz Analysis mode
0.5 to 30 Hz AED mode
Common Mode Rejection:>=60dB
Heart Rate Meter: 20 to 300 BPM.
Heart Rate Alarms: User-selectable.
Size: 0.125 0.25 0.5 1 2 4 cm/mv and auto-ranging.
ECG Output: 1 V/mV.
Heart Rate Response to Irregular Rhythm: (AAMI EC13-1992 section 4.1.2.1.e.)
Alarms
Heart Rate Spo2 Alarm:
Audible: 5 pulse 800 tone with a PW of 150 msec a PRI of 225 msec and a repetition interval of 10 seconds.
Visual: Heart Rate Alarm causes the displayed heart rate to flash at 2 Hz. This display is located at the top of the display and is 0.4″ high and 0.28 to 0.840″ wide depending on num-ber of digits in the heart rate. Is amber black white or whatever the color the display text is.
Lead Fault Alarm:
Audible: 3 pulse 500 Hz triplet tone with a PW of 200 msec a PRI of 310 msec. When the HR alarm is set or the pacer is on the lead fault tone repeats at a repetition interval of 20 seconds.
Visual: Lead Fault condition causes a “LEAD FAULT” message to be displayed on the trace along with a dashed line the width of the trace. The text is 0.18″ high and is the color of the display text. The dashed line is 5″ Long the width of the display. The signal is not modulated.
Physiological Alarms (Spo2):
Audible: See Heart Rate Alarm
Visual: Physiological alarms cause the displayed parameter to flash at 2 Hz. Color is amber white or the same as the display colored text.
Mute Duration: 90 seconds.
Recorder
Type: High-resolution thermal array.
Annotation: Time date ECG lead ECG gain heart rate defibrillation and treatment summary ACLS events.
Paper Width: 50 mm.
Paper Speed: 25 mm/sec 50 mm/sec 12 Lead 50 mm/sec
Delay: 6 seconds.
Frequency Response:
Automatically set to monitor’s frequency response.
Battery
High Capacity Type: Ni-MH 12V volt – MEDITECH
Up to 4 hours ECG monitoring or 110 full-energy dis-charges or 3 hours combined ECG Spo2 and monitor-ing
Proper battery care is required to maintain maximum avail-able capacity.
Low Battery Indicator:
Flashing low battery icon on display and flashing LED on front panel..
Recharge Rate: 80% in 7.5 hours. 100% in 9 hours.
General
Weight: 10 pounds (4.95 kg) (basic configuration).
Size: 13 x 12.5 x 5.3 inches (33 x 31.8 x 13.5 cm).
Operating:
Temperature*: 0 to 45° C
Humidity* (NC): 15 to 95% RH (30 to 90% with CO2 probe)
Vibration*: MIL-STD 810E
Shock / Drop*: MIL-STD 810E
Altitude: Up to 4572 M (15000 feet)
Transport and Storage:
Temperature: -30 to 70°C (-20 to 70°C with CO2 probe)
Humidity: 15 to 95% RH (non-condensing)
Atmospheric pressure: 860 to 1060 hPa
Shock/vibration: ISTA 1A
Enclosure Protection*:
Solid Foreign object: IEC 529 IP2X
Water: IEC 529 IPX4.
All tests performed per AAMI DF-2 Defibrillation Standard.
Operating Power:
Ni-MH 12 volt – MEDITECH
SAED Rhythm Recognition Performance
The DEFI XPRESS SAED algorithm exceeds the requirements of ANSI/AAMI
You must be logged in to post a review.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
12 Channel ECG Cardio7 Bionet
12 Channel ECG Cardio7 Bionet
12 Channel ECG Cardio7 Bionet device is classified as follows, in accordance with IEC60601-1. There are a lot of ECG Machines in the market but the reputation of Bionet is absolutely phenomenal, please bear in mind that Bionet is USA Based company but the products are manufactured in Korea. However each and every single product is FDA Approved. 12 Channel ECG Cardio7 Bionet device or system is suitable for use in all establishments other than domestic and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. Mains power should be a typical commercial or hospital environment. For more information regarding the product please feel free to contact us.CLICK HERE TO DOWNLOAD THE CATALOG Bionet Cardio7_ECG.pdf
Features:
12 channel interpretive ECG for adult, pediatric and neonatal use over 130 kinds of interpretation results based on advanced Minnesota code, HRV (Hearth Rate Variability analysis)- memory for up to 200 patients
- real-time preview monitor
- PC compatible through LAN or Wi-Fi
- multi-Ianguage selectable software (GB, RU, FR, DE, IT, CN, ES, TU, PL, RU, PT)
- lead fault message
- pace maker detection
- automatic arrhythmia detection
- 3, 5, 10 minutes long term recording
- grid function allows you to use low cost plain fax paper
- wide and clear colour 7” TFT LCD (800x480)
- touch screen for easy operation
- full disclosure function
Specification:
ECG leads: 10 lead, 12 channel simultaneous ECG and acquisition • Dimension: 300(W) x 299(H) x 123(D)mm, approx. 3.5 kg • Recording channel: 3 channels + 1 rhythm, 3 channels + 3 rhythm, 6 channels + 1 rhythm, 12 channels, 60 seconds 1 channel, 3, 5, 10 minutes 1 channel and beat report • Sensitivity: 2.5, 5, 10, 20, auto (l~aVF: 10, V1~V6: 5) mm/mV • Printing speed: 5, 12.5, 25, 50, 100 mm/s • Sampling rate: 2,000 samples/sec • Filters: AC (50/60 Hz, -20 dB or better) • Muscle (25~35 Hz, -3dB or better) • Base line drift (0.05, 0.1, 0.2 Hz, -3dB or better) • Low pass filter: off, 40 Hz, 100 Hz, 150 Hz • Display: 7" color TFT LCD display (800x480), 12 channels preview ECG wave • Monitor display: ID, date, sensitivity, speed, filter, form, rhythm lead • User interface: Touch screen (alphanumeric and symbol available), Keyboard, rotary push-knob (pop-up menu) • Patient data: ID, name, age, sex, height, weight, smoke, race • Basic measurement: Heart rate, PR int, QRS dur, QT/QTc, P-R-T axis • Recorder: Thermal print head, roll paper, A4 report paper: 210x300 mm (8.5"x11") • Resolution: - Vertical: 8 dot/mm - Horizontal: 16 dot/mm • Electrical: - Internal noise: 20 µV (p-p) max - Input circuit: floating input - Input impedance: =50 MO - Input voltage range: = ±5 mV - Common mode rejection: > 105 dB - DC offset voltage: = ±400 mV - Time constant: 3.2 sec - Patient leakage current: < 10 µA - Frequency response: 0.05 ~150 Hz - Isolated and defibrillation protected • Signal quality control: Disconnected lead detection, Pacemaker pulse detection • ECG data storage: storage for 200 ECGs (Internal on flash memory) • Power: 100~240 VAC, 50/60 Hz or battery (option) 2.0~1.0 A, 60 VA max • Battery (Li-Ion): 4 hours of normal use (approx.200 ECG printouts) • Communication: PC connection with LAN D2 Wi-Fi • Safety conformity: Class I, Type CF, CE, CSA, FDA, KFDA, CFDA, CCC General Information of 12 Channel ECG Cardio7 Bionet For more information regarding ecg machine price in Pakistan, 3 channel ecg machine price in Pakistan or 12 channel ecg price in Pakistan please feel free to contact us. Our technical staff will provide you full back-up and support in all over Pakistan. When talk about ecg price in Pakistan or ecg machine price in Pakistan we are the number one company in entire Pakistan to provide ECG Machines in Pakistan, ETT Machines in Pakistan, Patient Monitors in Pakistan, Cardiac Monitors in Pakistan, AED in Pakistan, Defibrillator in Pakistan and almost all type of Cardiology Equipment in Pakistan.Micro Centrifuge Tube 2.0ml
Micro Centrifuge Tube 2.0ml
Micro Centrifuge Tube 2.0ml is one of the best and reliable centrifuge tubes made by Biomed Pakistan. The best thing about the centrifuge tubes are that they are autclaved and packed in different capacities as per the discretion of end-user. Micro Centrifuge Tube 2.0ml gives the best result and quality is 100% guaranteed. For more information regarding Micro Centrifuge Tube 2.0ml in Pakistan please feel free to contact us. Features:- Polypropylene clear polymer facilitates visualization of samples
- Attached snap caps
- Rated to 20,000 x G
- Graduations at every 100 μL for easy volume estimation
- Frosted writing sections in tube surface and tube cover for easy sample identification.
- Temperature range: -80°C to +121°C (Autoclave able)
- Certified free of detectable RNase, DNase & Pyrogen
- Affinity purification or affinity chromatography
- Immunodepletion
- Immunoprecipitation (IP)
- Mechanical failure of the machine
- Lab equipment failure (tubes, etc.)
- Aerosol generation
- Operator Error
- Operating Procedures
- Develop and implement a strict cleaning, storing, and maintenance protocol.
- Only use manufacturer compatible centrifuge, rotor, buckets, caps, and adapters.
- Replace centrifuge parts including bottles, tubes, and O-rings at the first sign of damage.
- Assemble the bottles, buckets, and rotor per the manufacturer’s instructions.
- Tightly seal all tubes and safety cups.
- Close lid during operation.
- Allow to come to complete stop before opening.
- Guideline for Safe Operation
- Use safety cups whenever possible.
- Disinfect or clean weekly and after all spills or breakages.
- Lubricate O-rings and rotor threads weekly.
- Do not operate the centrifuge without the rotor properly balanced.
- Do not use rotors that have been dropped.
- Inspect the speed disk for sign of damage if using an ultra-speed unit and
- discontinue use if damaged. Inspect the rotor and tube cavities for signs of damage and discontinue use if damaged.
- Contact your centrifuge representative for specific information.
- Micro Centrifuge Tube 2.0ml available in Pakistan in 1.0ml, 1.5ml, 2ml
Microplate Reader Rayto RT-6100
Microplate Reader Rayto RT-6100
Microplate Reader Rayto RT-6100 is one the best Microplate Reader in Pakistan, RT-6100 has one of the best quality Elisa Microplates reading. When we talk about the detection of Biological and Chemical data there are a lot of Equipment available in Pakistan and worldwide to get them detected through ELisa's, Enzyme Activities, Nuleic and Protein Quantification. When we talk about the Microplate Reader price in Pakistan, Microplate Reader Rayto RT-6100 is the ultimate choice of Lab Technicians. For more information, questions and queries please feel free to contact us. Features:- PC Controlled System
- 8 Channel optical fiber system enables 5 sec reading for 96 wells plate.
- Calculation Modes includes ABS, Cut-off, Curve, Linear, Log, Exponent, Power and 4PL Regressions.
- Upto 12 different tests can be performed in a single plate.
- Power Laboratory Management Software to store more than 100 Programs, 100,000 results.
- Powerful QC programs including Westguard Rules and instant method, automatic alarm,
- Multiform test reports output.
- Lamp saving and plate shaking feature.
- Save data automatically when power off unexpectedly.
- Compatible with all external printers supported in Windows.
- Powerful Internet Connection enables remote data sharing and OS update.
- Standard Language is English, Multiple Language Software is available on request.