Electric CPR Manikin Little Anne Laerdal
Electric CPR Manikin Little Anne Laerdal
Electric CPR Manikin Little Anne Laerdal is electric CPR manikin with feedback. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
Features:
Electric CPR Manikin Little Anne Laerdal
Cleaning
Do not use liquids to clean inside the manikin.
Do not submerge any parts.
Battery
Only use consumer grade, non-rechargeable, carbon zinc or alkaline batteries, LR6 1.5V AA. Batteries must be replaced with correct type. Remove batteries if product is not to be used for an extended period.
Federal Communications Commission
Statement and Industry Canada Statements This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference
2. This device must accept any interference received, including interference that may cause undesired operation.
Click here QCPRClassroomSellSheet.pdf to download product catalog, for more information please feel free to contact us +92-322-4602203 or Email: info@zirarenterprises.com, zirarenterprises@gmail.com
Please also see Prestan Manikins available in stock
Electric CPR Manikin Little Anne Laerdal
Electric CPR Manikin Little Anne Laerdal is electric CPR manikin with feedback. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
Features:
Electric CPR Manikin Little Anne Laerdal
Cleaning
Do not use liquids to clean inside the manikin.
Do not submerge any parts.
Battery
Only use consumer grade, non-rechargeable, carbon zinc or alkaline batteries, LR6 1.5V AA. Batteries must be replaced with correct type. Remove batteries if product is not to be used for an extended period.
Federal Communications Commission
Statement and Industry Canada Statements This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference
2. This device must accept any interference received, including interference that may cause undesired operation.
Click here QCPRClassroomSellSheet.pdf to download product catalog, for more information please feel free to contact us +92-322-4602203 or Email: info@zirarenterprises.com, zirarenterprises@gmail.com
Please also see Prestan Manikins available in stock
You must be logged in to post a review.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
Automated Hematology Analyzer DC 2400 Plus
Automated Hematology Analyzer DC 2400 Plus
Automated Hematology Analyzer DC 2400 Plus is one of the best Fully automated hematology analyzer which can perform two duties at the same time monitoring of the blood cells having diseased cells and at the same time counting them. DiA CELL DC-2400 PLUS is very useful machine for the patients, laboratory staff etc, some of the features are: Features:- Perfect QA
- Simple to Operate
- Convenient Maintenance
- Advanced Design
Carry Over: RBC, WBC, HGB <0.5%, PLT<1.0%
Operating Interface: Colorful Windows interface, no need connecting computer. Operating by graphic button with mouse and keyboard
Display: Big size 10.4’’ TFT LCD, all parameters and histograms displayed in the same screen
Print Mode: Internal high-speed thermal printer. Optional connection with specified external printer. English printouts
Reagents System: Open reagent system. No cyanogen reagents. Provide original reagents.
Connection Port: USB, RS-232, network interface
Power: Maximum 150VA
Environment: Temperature 10℃-35℃. Relative humidity: 10%-90%
Power Supply: 220(1±10%)V, (50±1)Hz. 90V-260V, 50-60Hz broad range power available for different Countries
Dimension: 520mm×460mm×420mm
Weight: 23Kg
Micro Centrifuge Tube 2.0ml
Micro Centrifuge Tube 2.0ml
Micro Centrifuge Tube 2.0ml is one of the best and reliable centrifuge tubes made by Biomed Pakistan. The best thing about the centrifuge tubes are that they are autclaved and packed in different capacities as per the discretion of end-user. Micro Centrifuge Tube 2.0ml gives the best result and quality is 100% guaranteed. For more information regarding Micro Centrifuge Tube 2.0ml in Pakistan please feel free to contact us. Features:- Polypropylene clear polymer facilitates visualization of samples
- Attached snap caps
- Rated to 20,000 x G
- Graduations at every 100 μL for easy volume estimation
- Frosted writing sections in tube surface and tube cover for easy sample identification.
- Temperature range: -80°C to +121°C (Autoclave able)
- Certified free of detectable RNase, DNase & Pyrogen
- Affinity purification or affinity chromatography
- Immunodepletion
- Immunoprecipitation (IP)
- Mechanical failure of the machine
- Lab equipment failure (tubes, etc.)
- Aerosol generation
- Operator Error
- Operating Procedures
- Develop and implement a strict cleaning, storing, and maintenance protocol.
- Only use manufacturer compatible centrifuge, rotor, buckets, caps, and adapters.
- Replace centrifuge parts including bottles, tubes, and O-rings at the first sign of damage.
- Assemble the bottles, buckets, and rotor per the manufacturer’s instructions.
- Tightly seal all tubes and safety cups.
- Close lid during operation.
- Allow to come to complete stop before opening.
- Guideline for Safe Operation
- Use safety cups whenever possible.
- Disinfect or clean weekly and after all spills or breakages.
- Lubricate O-rings and rotor threads weekly.
- Do not operate the centrifuge without the rotor properly balanced.
- Do not use rotors that have been dropped.
- Inspect the speed disk for sign of damage if using an ultra-speed unit and
- discontinue use if damaged. Inspect the rotor and tube cavities for signs of damage and discontinue use if damaged.
- Contact your centrifuge representative for specific information.
- Micro Centrifuge Tube 2.0ml available in Pakistan in 1.0ml, 1.5ml, 2ml

Reviews
There are no reviews yet.