Features
- 12.1 inch TFT color screen , big screen could show more information.
- Screen could be rotated freely, suitable to operate in any angle and height
- With heater device to prevent water into ventilator
- Could show Paw-t、Flow-t、Volume-t、Paw-V、Flow-V five waveform at the same time, also could show one or
- several waveform according to our operation.
- Curve size ,time scale, pressure-flow ratio adjustable, watch the details more good.
- Curve pause function, could watch details.
- Flow, pressure two trigger function, could effect at a same time.
- Automatically inspiratory synchronous nebulizing function, nebulizing time adjustable;
- 100% Oxygen inspiratory function, oxygen inspiratory time is adjustable.
- High, medium, low- grade alarm function;
- Alarm record functions, could record the last 100 pieces of information, show alarm grade, alarm time and the alarm
- parameter.
- Pressure, volume, time respiratory mode security, could inspect pressure in inspiratory phase, volume, time exceed the
- regulated value, turn into expiratory, ensure patient safety.
- Volume security function, keep the minimum tidal volume in pressure mode.
- Adjust MMV function automatic, adjust inspiratory pressure and breathing frequency, approaching the target tidal
- volume
- and minute ventilator.
- VGA connector could output the screen signal to other screen
- Specification
Operating Modes
- Volume Control Ventilation (VCV)
- Assisted/Controlled Pressure Control Ventilation (PCV),
- Assisted/Controlled Pressure Support Ventilation (PSV),
- SIMV(VCV)+PSV
- SIMV(PCV)+PSV
- Mandatory Minute Ventilation (MMV)
- Continuous Positive Airway Pressure(CPAP)
Parameter
- Application scope: Pediatric and adult
- Driven mode: pneumatically driven and electronically controlled
- Display:12.1 TFT screen
- Working mode: Pressure and volume
- Ventilation wave type: squire wave, deceleration wave
- FiO2: 21% to 100%
- PEEP/CPAP: 0 to 40 cmH2O
- Inspiratory Sensitivity:
- Flow triggered: 0.5 to 20 L/min, OFF
- Pressure triggered: -1 to -20 cmH2O, OFF
- Tidal Volume: 20 to 2000 mL
- Breath frequency: 1 to 100 bpm
- I:E Ratio: 5.0 : 1 to 1 : 5.0
- Inspiratory plateau: 0 to 50%
- Inspiratory Flow Wave Shape(VCV): Rectangular wave and Decelerating wave
- SIGH: 1.0 to 2.0
- Breath frequency(SIMV): 2 to 40bpm
- Inspiratory time (SIMV): 0.1 to 12 S
- Pressure Support Ventilation (PSV): 0 to 40 cmH2O
- Expiratory Sensitivity for PSV : 10% to 75% of the initial flow
- Maximum Inspiratory time (PSV): 1.0 to 8.0 S
- Pressure Control Ventilation(PCV): 0 to 40 cmH2O
- Minimum Tidal Volume(PCV and PSV): 50 to 1500 mL
- Backup Rate (PSV): 2 to 40 bpm
- Object Tidal Volume(MMV): 20 to 2000 mL
- Ventilation volume(MMV): 0.5 to 40.0 L/min
- Nebulizer time: 30 minutes
Monitoring
- Breathing wave: Pressure vs time curve,Flow vs time curve,Volume vs time curve,Pressure vs volume loops,Flow vs volume loops
- Expiratory tidal volume:,
- Breath frequency(bpm),
- PEEP:
- FiO2
- MV
- Insipiratory Tidal volume(TV_Insp):
- I:E ratio:
- Freq_indepen:
- MV_Indepen:
- Pmean
- Pflat:,
- Airway Pressure
- Ppeak,
- Minute Ventilation,
- Oxygen concentration
Alarms
- High tidal volume alarm
- Low tidal volume alarm
- High minute ventilation alarm
- Low minute ventilation alarm
- High breathing frequency alarm
- Low breathing frequency alarm
- High peak pressure alarm
- Low peak pressure alarm
- High PEEP pressure alarm
- Low PEEP pressure alarm
- High oxygen concentration alarm
- Low oxygen concentration alarm
- Apnea time alarm
- Respirtory arrest alarm
- AC power fail alarm
- Air source Low pressure alarm
- Oxygen source low pressure alarm
- Batterydisconnect alarm
- Low battery alarm
- Circle leakage alarm
- Circle block alarm
Air compressor BC100 (Optional)
Feature:
Low noise medical air Compressor, very stable performance, safe and reliable,
Air Compressor with LCD screen to display output pressure, provide safe, secure and permanent motivation
Compact design and easy to transfer
Assembled with clean control module, supplying cleaner and safer air to the patients
Effective sound-absorbing materials
Match with various ventilator of international standard in the world
Specification
| NO. | Name | Specifications | Notes |
| 1 | Output gas flow | ≥40L/min | |
| 2 | Output gas pressure | 0.3~0.4Mpa | Adjustable |
| 3 | Output gas filter accuracy | 0.03μm | |
| 4 | Air compressor pump | 1sets | |
| 5 | Efficient rate for particle filtration | 99% | |
| 6 | Dew point of output gas: | 0~10℃ | Dried output gas |
| 7 | Noise | 46~48dB(A) | |
| 8 | Power supply | 220V±15% ,50HZ or 110V±15%,60HZ | |
| 9 | Power | <800W | |
| 10 | Working Environment | Temperature 0~40°C
Humidity<90RH |
|
| 11 | Net Weight |
40kg |
|
| 12 | Size |
510*560*610mm |
|
POWER REQUIREMENT
Main power: from 85 to 265VAC 47-63HZ
Automatic voltage switch
Internal battery: 12VDC; 7AH
Automatic recharge.
Estimated duration: more than 2 hours when completely charged.
The display shows an icon with the charge level.
PNEUMATIC REQUIREMENT
Oxygen: pressure 2.8 to 6 bar ISO5359 connector
Air: pressure 2.8 to 6 bar ISO 5359 connector
ICU Ventilator Lifepro 8 MDX-USA
ICU Ventilator Lifepro 8 MDX-USA are designed for the most demanding ICU environments. Built to last, the LifePro 8 ICU ventilator offers robust and consistent performance when its needed. Click the link to download complete catalog LifePro™ 8 ICU VENT.pdf
ICU Ventilator Lifepro 8 MDX-USA
Features
- 12.1 inch TFT color screen , big screen could show more information.
- Screen could be rotated freely, suitable to operate in any angle and height
- With heater device to prevent water into ventilator
- Could show Paw-t、Flow-t、Volume-t、Paw-V、Flow-V five waveform at the same time, also could show one or
- several waveform according to our operation.
- Curve size ,time scale, pressure-flow ratio adjustable, watch the details more good.
- Curve pause function, could watch details.
- Flow, pressure two trigger function, could effect at a same time.
- Automatically inspiratory synchronous nebulizing function, nebulizing time adjustable;
- 100% Oxygen inspiratory function, oxygen inspiratory time is adjustable.
- High, medium, low- grade alarm function;
- Alarm record functions, could record the last 100 pieces of information, show alarm grade, alarm time and the alarm
- parameter.
- Pressure, volume, time respiratory mode security, could inspect pressure in inspiratory phase, volume, time exceed the
- regulated value, turn into expiratory, ensure patient safety.
- Volume security function, keep the minimum tidal volume in pressure mode.
- Adjust MMV function automatic, adjust inspiratory pressure and breathing frequency, approaching the target tidal
- volume
- and minute ventilator.
- VGA connector could output the screen signal to other screen
- Specification
Operating Modes
- Volume Control Ventilation (VCV)
- Assisted/Controlled Pressure Control Ventilation (PCV),
- Assisted/Controlled Pressure Support Ventilation (PSV),
- SIMV(VCV)+PSV
- SIMV(PCV)+PSV
- Mandatory Minute Ventilation (MMV)
- Continuous Positive Airway Pressure(CPAP)
Parameter
- Application scope: Pediatric and adult
- Driven mode: pneumatically driven and electronically controlled
- Display:12.1 TFT screen
- Working mode: Pressure and volume
- Ventilation wave type: squire wave, deceleration wave
- FiO2: 21% to 100%
- PEEP/CPAP: 0 to 40 cmH2O
- Inspiratory Sensitivity:
- Flow triggered: 0.5 to 20 L/min, OFF
- Pressure triggered: -1 to -20 cmH2O, OFF
- Tidal Volume: 20 to 2000 mL
- Breath frequency: 1 to 100 bpm
- I:E Ratio: 5.0 : 1 to 1 : 5.0
- Inspiratory plateau: 0 to 50%
- Inspiratory Flow Wave Shape(VCV): Rectangular wave and Decelerating wave
- SIGH: 1.0 to 2.0
- Breath frequency(SIMV): 2 to 40bpm
- Inspiratory time (SIMV): 0.1 to 12 S
- Pressure Support Ventilation (PSV): 0 to 40 cmH2O
- Expiratory Sensitivity for PSV : 10% to 75% of the initial flow
- Maximum Inspiratory time (PSV): 1.0 to 8.0 S
- Pressure Control Ventilation(PCV): 0 to 40 cmH2O
- Minimum Tidal Volume(PCV and PSV): 50 to 1500 mL
- Backup Rate (PSV): 2 to 40 bpm
- Object Tidal Volume(MMV): 20 to 2000 mL
- Ventilation volume(MMV): 0.5 to 40.0 L/min
- Nebulizer time: 30 minutes
Monitoring
- Breathing wave: Pressure vs time curve,Flow vs time curve,Volume vs time curve,Pressure vs volume loops,Flow vs volume loops
- Expiratory tidal volume:,
- Breath frequency(bpm),
- PEEP:
- FiO2
- MV
- Insipiratory Tidal volume(TV_Insp):
- I:E ratio:
- Freq_indepen:
- MV_Indepen:
- Pmean
- Pflat:,
- Airway Pressure
- Ppeak,
- Minute Ventilation,
- Oxygen concentration
Alarms
- High tidal volume alarm
- Low tidal volume alarm
- High minute ventilation alarm
- Low minute ventilation alarm
- High breathing frequency alarm
- Low breathing frequency alarm
- High peak pressure alarm
- Low peak pressure alarm
- High PEEP pressure alarm
- Low PEEP pressure alarm
- High oxygen concentration alarm
- Low oxygen concentration alarm
- Apnea time alarm
- Respirtory arrest alarm
- AC power fail alarm
- Air source Low pressure alarm
- Oxygen source low pressure alarm
- Batterydisconnect alarm
- Low battery alarm
- Circle leakage alarm
- Circle block alarm
Air compressor BC100 (Optional)
Feature:
Low noise medical air Compressor, very stable performance, safe and reliable,
Air Compressor with LCD screen to display output pressure, provide safe, secure and permanent motivation
Compact design and easy to transfer
Assembled with clean control module, supplying cleaner and safer air to the patients
Effective sound-absorbing materials
Match with various ventilator of international standard in the world
Specification
| NO. | Name | Specifications | Notes |
| 1 | Output gas flow | ≥40L/min | |
| 2 | Output gas pressure | 0.3~0.4Mpa | Adjustable |
| 3 | Output gas filter accuracy | 0.03μm | |
| 4 | Air compressor pump | 1sets | |
| 5 | Efficient rate for particle filtration | 99% | |
| 6 | Dew point of output gas: | 0~10℃ | Dried output gas |
| 7 | Noise | 46~48dB(A) | |
| 8 | Power supply | 220V±15% ,50HZ or 110V±15%,60HZ | |
| 9 | Power | <800W | |
| 10 | Working Environment | Temperature 0~40°C
Humidity<90RH |
|
| 11 | Net Weight |
40kg |
|
| 12 | Size |
510*560*610mm |
|
POWER REQUIREMENT
Main power: from 85 to 265VAC 47-63HZ
Automatic voltage switch
Internal battery: 12VDC; 7AH
Automatic recharge.
Estimated duration: more than 2 hours when completely charged.
The display shows an icon with the charge level.
PNEUMATIC REQUIREMENT
Oxygen: pressure 2.8 to 6 bar ISO5359 connector
Air: pressure 2.8 to 6 bar ISO 5359 connector
You must be logged in to post a review.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
BioSafety Cabinet Class II Type A2
Bio Safety Cabinet Class II Type A2
BioSafety Cabinet Class II Type A2 is the best option for laboratories where the hazardous substance can be exposed in the air and contaminate it and it is very useful to save the human beings as well as lab operators. BioSafety Cabinet is also called biological safety cabinet. We are manufacturer of BioSafety Cabinet Class II Type A2 in Pakistan for more than a decade. We have ample experience in manufacturing and providing back-up and support to the technical staff. For more information about BioSafety Cabinet Class II Type A2 in Pakistan or anywhere in the world please feel free to contact us at +923224602203 (whatsapp or call) you can also email us at info@zirarenterprises.com, zirarenterprises@gmail.com or log on to our website www.zirarenterprises.comTechnical Specification:
- Support stand with wheels
- For product, personal and Environmental Protection
- Supply Filter size = 48 “ 24” x 3”
- 30% exhaust air filter size 12” x 12” x 3”
- Average air velocity = 80- 110 F.P.M
- Inner base and three sides are made up of S.S 304 18 SWG with perforation
- Outer side is made up of 18 SWG galvanized Powder coated sheet
- With florescent and U.V lamp
- With gas connection point optional
- One electric socket inside the chamber
- Front sash is of Acrylic sheet with motorized movement
- External dimension 56” x 35” x 80” Approx ( May change a little during fabrication) height is included with stand
- Digital controlled with LCD display ( Built in hour meter for the filter life’s )
- One Year Parts Warranty
BP Aneroid Riester Germany
BP Aneroid Riester Germany
BP Aneroid Riester Germany isn't your average aneroid blood pressure monitor. Sure, it fits snugly in the palm of your hand, making it portable and convenient. But within that compact design lies a powerhouse of features that cater to both healthcare professionals and self-monitoring individuals.Designing and Planning of Operation theaters
- Protective Zone: Entrance and changing rooms.
- Clean Zone: Recovery rooms and pre-operative holding.
- Aseptic Zone: The actual sterile operating rooms and scrub stations.
- Disposable Zone: Areas for dirty linen and waste removal.
Handheld Hemoglobin Meter BHM-101
Handheld Hemoglobin Meter BHM-101
Handheld Hemoglobin Meter BHM-101 is one of the best and most reliable Handheld Portable Hemoglobin Meter the sensors are made by the German Technology and it is one the best quality Hemoglobin Meters used worldwide. The best thing about these meters are that Patients don't have to go through the Lab tests in order to have their Hemoglobin Analysis. Handheld Hemoglobin Meter BHM-101 is very useful for the patients having low Hemoglobin in their blood stream. For more information please feel free to contact us. Handheld Hemoglobin Meter BHM-101 by Sinocare Please Click here to see our Full Range of Portable MetersSpecification:
| Methodology | Reflectance photometer |
| Measurement Range: | HB:4.5-25.6g/dL,45-256g/dL2.8-15.9mmol/L |
| Specimen: | Whole blood(capillaryandvenous) |
| Power Source: | 1200mAhbuilt-inlithiumbatterySuperLCD |
| Battery Endurance: | Aftercyclecharge300times,electricquantityreduce30% |
| Unitsof Measurement: | g/dL,g/L,mmol/L |
| Sample Volume: | 10μL |
| TestT ime: | 15seconds |
| Memory: | 800records |
| Automatic ShutOff | 5minutesafterlastuse |
| Meter Size: | 136*65*25mm(L*W*H) |
| Weight: | 90g |
| Meter Storage Conditions: | 0-55C;≤90% RH |
| System Operating Conditions: | 10-40°c;≤90% RH;height<altitude2000m |
| Test strip Storage Conditions: | 2~30C;s90% RH |
| Warranty Period: | 2 years |
Hermetic Doors
Hermetic Doors
Hermetic Doors also known as Hermetic sliding door or automatic doors are required where hygiene and the leakage of air control is critical. These doors takes less space and sealed completely form the edges so no air, gases or dust particles can pass through out of the operation theater. We have best team in market to install these doors with top quality material at very competitive prices. For further queries feel free to contact us 0322-4602203Isoflurane Vaporizer MDX USA
Isoflurane Vaporizer MDX USA
Isoflurane Vaporizer MDX USA Model: Hiper 2000 is one of the best anesthetic vaporizer in the world made by MDX Instruments USA, it efficiently filters the anesthetic agents and provides gas flow. The Hiper 2000 serial anesthetic vaporizer combine the feature of ergonomics, accuracy safety and reliability, HIPER 2000 vaporizer with the sophisticated design would provide a reliable and safe solution in filler types and mounting types, Features:- Innovative latest design of delivery system, Hiper vaporizer delivery accurate concentrations under varying conditions of variable flowrate, pressure etc
- HIPER 2000 vaporizers are calibrated by the skilled technicians. The advanced temperature-compensation system can make the concentration delivery stable.
- Hiper 2000 is designed sophisticated and manufactured strictly conforming to the test standards i.e. ISO8835-4.
- HIPER 2000 vaporizer have been made by special high tech materials, which prove the anti-corrosion from agents, beside with special rubber gaskets, it can make sure agent leak proof and corrosion resistant,.
- HIPER 2000 vaporizer have safety locking device to prevent the anesthetic gas volatile accidentally.
- No need for the routing maintenance to HIPER vaporizers, it can provide the life long free calibration service,
- Flow Meter: 0.2-15:.Min - 0.2-10L/min for concentration > 5%
- Temperature 15 ~+35 Degree Celsius
- Humidity: 0-95%
- Atmospheric Pressure: 70-106Pa
- Storage/Transport Environment: Temperature -40 ~+65 degree Celsius