Pressure Regulators and Flow Meter Schonn Germany pressure regulators and our flowmeters for applications other than oxygen therapy (presented in the specific section) The supply of all medical gases through measurement devices requires accuracy and experience in manufacturing and development, so we underline once more that all these devices are made n full compliance with European standards and technical regulations, as well as requirements of 93/42/EEC Directive and the approval criteria set by national and international certified bodes.
The CE marking procedure s carried out according to the requirements of a complete EN ISO 13485 quality system. All regulators and flow meters are rigorously tested, both n flow-meter™ own quality-assurance laboratories and by independent validated laboratories, to ensure that the products meet all the requirements of the medical applications n any foreseeable therapeutic condition. Pressure regulators and flow meters are manufactured n full compliance of ISO 10524-1 and ISO 15002.
The Schönn range of Oxygen Therapy equipment provides a seamless solution between your medical gas
pipeline system (MGPS) and downstream patent suppler enabling a one stop provider for all your medical gas needs. Our high end devices provide the user with light weight, highly precise and accurate equipment, which allows clinical and nursing staff to be concerned about only one thing – the patent.
SCHÖNN flow meters are robust and tactile, providing the user with a quality assurance further backed by our extended 2 year warranty. Our aesthetically pleasing equipment can be supplied with our range of Bedhead trunking, SCHÖNN or Global terminal units thus eliminating any concern over equipment compatibility. The SCHÖNN range of downstream equipment can be supplied to British BS, German DIN or French AFNOR and AGA norms as well as a few others, which are available upon request.
Pressure Regulators and FlowMeter Schonn
Please see our complete range of Medical Gases & Infrastructure
Features:
- Oxygen Flowmeters are used to provide Oxygen to the patent from Medical Gas outlets through nasal cannula or mask by regulating flow rate and passing through a humidifier when required.
- Schönn Flow meters are specially designed for medical applications and are used with oxygen. Body of the Flow meter s made of chromium plated brass, which s the most hygienic material for use with oxygen.
- The scaled tube of the Flow meter s made of poly carbonate for high resistance to breakage and s
autoclavable. It s graded between 1-15 Ipm. - The Humidifier on the Flow meter can be sterilized at 150°C.
- Our Flow meters are available for direct connection to appropriate Terminal Unit, n compliance wth EN European Norms) BS ,DIN and AGA.
- Humidifying bottle is 200ml.
Pressure Regulators and FlowMeter Schonn
Pressure Regulators and Flow Meter Schonn Germany pressure regulators and our flowmeters for applications other than oxygen therapy (presented in the specific section) The supply of all medical gases through measurement devices requires accuracy and experience in manufacturing and development, so we underline once more that all these devices are made n full compliance with European standards and technical regulations, as well as requirements of 93/42/EEC Directive and the approval criteria set by national and international certified bodes.
The CE marking procedure s carried out according to the requirements of a complete EN ISO 13485 quality system. All regulators and flow meters are rigorously tested, both n flow-meter™ own quality-assurance laboratories and by independent validated laboratories, to ensure that the products meet all the requirements of the medical applications n any foreseeable therapeutic condition. Pressure regulators and flow meters are manufactured n full compliance of ISO 10524-1 and ISO 15002.
The Schönn range of Oxygen Therapy equipment provides a seamless solution between your medical gas
pipeline system (MGPS) and downstream patent suppler enabling a one stop provider for all your medical gas needs. Our high end devices provide the user with light weight, highly precise and accurate equipment, which allows clinical and nursing staff to be concerned about only one thing – the patent.
SCHÖNN flow meters are robust and tactile, providing the user with a quality assurance further backed by our extended 2 year warranty. Our aesthetically pleasing equipment can be supplied with our range of Bedhead trunking, SCHÖNN or Global terminal units thus eliminating any concern over equipment compatibility. The SCHÖNN range of downstream equipment can be supplied to British BS, German DIN or French AFNOR and AGA norms as well as a few others, which are available upon request.
Pressure Regulators and FlowMeter Schonn
Please see our complete range of Medical Gases & Infrastructure
Features:
- Oxygen Flowmeters are used to provide Oxygen to the patent from Medical Gas outlets through nasal cannula or mask by regulating flow rate and passing through a humidifier when required.
- Schönn Flow meters are specially designed for medical applications and are used with oxygen. Body of the Flow meter s made of chromium plated brass, which s the most hygienic material for use with oxygen.
- The scaled tube of the Flow meter s made of poly carbonate for high resistance to breakage and s
autoclavable. It s graded between 1-15 Ipm. - The Humidifier on the Flow meter can be sterilized at 150°C.
- Our Flow meters are available for direct connection to appropriate Terminal Unit, n compliance wth EN European Norms) BS ,DIN and AGA.
- Humidifying bottle is 200ml.
You must be logged in to post a review.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
Automatic Medical Gas Manifold Plant
Automatic Medical Gas Manifold Plant
Precision UK’s CPX Automatic Medical Gas Manifold Plant is manufactured under BS EN 13485 Medical Devices: Quality Management Systems. It provides a centralized source of bottled gas. The unit is designed to provide a duty and standby gas supply at a constant pressure via two banks of bottled gas cylinders with status monitoring. Specification:- A standard system would feature a central control panel with a header assembly.
- Digital display of bottle pressure for duty and standby banks.
- Electronic control with alarm and BMS outputs for remote status indication.
- The unit is designed for wall mounting as standard, however, options available include floor mounted assemblies and formats to suit customer requirements.
- Also available is a high flow capable of providing a distribution flow rate up to 2500l/min.
- Options – Touchscreen, BMS Modbus Digital Outputs, SMS Texting Alarm
- Designed to meet the requirements of:
- HTM 02-01 and SHTM 02-01: Medical Gas Pipeline Systems
- BS EN 7396: Pipeline Systems for Compressed Medical Gases and Vacuum
- C11 NHS: Model Engineering Specification – Medical Gases
- BS EN 10524-2 : Pressure Regulators
- BS EN 21969 High Pressure Flexible Connectors
- CE marked under Medical Device Directive 93/42/EEC with approval from British Standards Institute CE0086 classified as Class IIb Medical Device
Bed Head Unit Vertical
Bed Head Unit Vertical
Bed Head Unit Vertical is our specialty we at Zirar Enterprises install, assemble, fabricate and manufacture Bed Head Unit Vertical types and their composition are additionally extreme basic piece of the clinics, hospitals etc and it not only facilitate patients but also gives accommodation to the paramedic and nursing staff for better vertical view and to perform their life saving duties. Further essential advantage of vertical bed head unit is that it covers less space as compared to horizontal bed head units. Our specialized staff is totally all around, prepared and well taught in this specific field. please feel free to contact us anytime, we shall be glad to pay free visit, testing and commissioning. For post view click on this link Bed Head Vertical Technical Specification: - Material: Material is made of 99.9% pure aluminum, extruded from imported billet. Thickness: 2mm Size of Bed head unit: Standard size is 4 feet, but you can also customize as per your discretion. Paint: Jotun paint which is powdered coated, you can also choose paint of your choice. Color: Color can also be customize of customer's choice. Electrical Equipment: Clipsal, Australia. Electrical Accessories: 01 on and 01 off switch with 01 multi functional two pair of schuko sockets. Our valued clients can also modify it with their discretionary electrical accessories. Electrical Cables: For vertical bed head units we use one of the best electrical cables such as GM Cables, Newage Cables and Pakistan cables. However customer can also choose the cable brand as per their feasibility and budget. Patient Light: 600mm LED Light. Warranty: One year warrant with after sale service within a year, and 02 years paint warranty. Projects Completed:- Dow Medical University, Karachi
- Sheikh Zaid Hospital, Lahore
- Women Medical College, Islamabad
- Combined Military Hospital, Rawalpindi
- Ali Medical Complex, Islamabad
- Jinnah Hospital, Lahore
- Doctors Hospital, Lahore
- Omer Hospital, Lahore
- Rehman Medical Institute Peshawar
Degreased Copper Tube British Standard
Degreased Copper Tube British Standard
Degreased Copper Tube British Standard is Precision UK’s CPX Degreased Copper Tube British Standard is manufactured in the UK under BS EN 13485 Medical Devices: Quality Management Systems. All tube is manufactured under strict quality control procedures to ISO 9001:2008. CPX tube is the only British manufactured tube that is CE marked as a class IIa Medical Device 93/42/EEC with notified body British Standards Institute under CE0086. It is suitable for jointing degreased medical gas copper fittings and other medical gas equipment compliant to BS EN 13348, BS EN 1057, BS 2871 Part 1 Table X, EN 7396 and HTM 02-01. CPX copper tube is designed for use in Medical Gas Pipeline System (MGPS) installations and incorporates the specialist requirement of the MGPS industry to include cleanliness, packaging and usability required to attain the levels of quality as stated particularly in HTM 02-01. Specification: -- Each pipe is cleaned to have a maximum carbon level 0.20mg/dm².
- Each pipe is individually end capped and bundled in sealed polythene bags to maintain cleanliness.
- Chemical composition CU.DHP to ISO 1190-1/CW024A to EN1412.
- All copper tube is manufactured under strict quality control procedures to ISO 9001 and CE marked under the Medical Device Directive 93/42/EEC (CE0086) Class IIa.
- BSI Kitemarked
- Batch numbering for traceability is included on all pipework.
- All copper tube from sizes 12mm through to 108mm are engraved/permanently ink marked with the following information: EN 13348, nominal dimensions, manufacturer details, part no., CE Mark, Medical Device Directive to 93/42/EEC, time and date of production.
- 25 year guarantee.
Manual/Semi Automatic Manifold Systems
Manual/Semi Automatic Manifold Systems
Manual/Semi Automatic Manifold Systems main using at small and medium hospitals. When using the medical gas oxygen manifold, several cylinders need to be connected to the manifold pipeline. The oxygen gas is first filtered and decompressed, and then transported through the main pipe to the end of use. The function of the secondary regulator is to stabilize the outlet gas flow of the main pipeline. CGA standard adapter port and inlet connection thread. Cleaned for medical Oxygen, Air, N2O, CO2 gas. Open type manifold connector cylinder number according to the client request. 3 years warranty. Specifications:- Applicable gas: O2, Air, CO2, N2, and N2O etc.
- High flow capacity regulator
- Open style cylinder number according to the client request
- Pass the pressurization testing, welded in silver, much safety and stable
- Wall mount simplifies installation, easy installed
- Size of the connecting hose is customized
- CGA4.1 and ISO15001 Standard
- Maximum pressure 3,000 psi
General Information:
An oxygen manifold system is a critical component in the delivery of oxygen in medical facilities. The system consists of a series of oxygen cylinders connected to a common manifold, which regulates the flow of oxygen to different parts of the hospital or clinic. The manifold system ensures a continuous supply of oxygen to patients, even if one cylinder runs out of gas. The manifold system is designed to be reliable and durable, and it is typically made of high-quality materials that can withstand the high pressures of oxygen gas. The manifold system can be configured in different ways depending on the specific needs of the medical facility. For example, some manifold systems may be designed to supply oxygen to a single ward or room, while others may supply oxygen to multiple floors of a hospital. One of the benefits of an oxygen manifold system is its ability to provide a centralized source of oxygen, which can reduce the need for multiple oxygen tanks scattered throughout a facility. This can make it easier to manage the inventory of oxygen tanks and reduce the risk of running out of oxygen during a medical emergency. Overall, an oxygen manifold system is an essential component of any medical facility that requires a reliable supply of oxygen for patient care. Proper maintenance and monitoring of the system are crucial to ensure its continued reliability and safety. Manufactured by AMCAREMED Please click to read Medical Gas and Pipeline Network For more information please feel free to call us at+92-322-4602203 or Email: info@ziarenterprises.com, zirarenterprises@gmail.comMedical Gas Outlets Precision UK
Medical Gas Outlets Precision UK
Medical Gas Outlets Precision UK also known as CPX Terminal Units are designed and manufactured in the UK under BS EN 13485 Medical Devices: Quality Management Systems. The units comprise of a first fix, second fix and a second fix valve assembly and connect medical appliances to the gas supply system. Please also see our Medical Gas Outlets Precision UK & Medical Gases & Infrastructure The first fix comprises of a brass pipeline termination cylinder with a 12mm BS EN 13348 copper pipe for brazing to the fixed pipeline system, or with a NIST BS EN 18082 (non-interchangeable screw thread) connector for connection to a hose assembly. A mounting box suitable for both surface and flush installations is also provided. CPX British Standard and DIN Standard Gas Outlets utilize a common first fix assembly. The CPX Terminal Unit is designed to enable gas probes to be connected and disconnected easily and with minimal effort and the same time as giving a strong, reliable and secure connection. They are available for oxygen, nitrous oxide, 50% oxygen/50% nitrous oxide mixture, medical air, surgical air, medical vacuum, carbon dioxide, nitrogen and AGSS. The terminal units can be flexibly integrated into any type of installation including surface, flush, bedhead and pendant and are supplied with a 3 year warranty. Test plugs are included with flush, surface, and bedhead types for first fix pressure testing on site. DIN Standard CPX DIN gas outlets are manufactured and designed in our UK factory, full metal construction, Gas Indexing as EN 13260-2, EN 9170 and Medical Gas Pipelines EN 7396.
Standards: Designed to Meet the requirements of
Medical Gas Outlet Precision UK
- HTM 02-01 Medical gas Pipeline Systems
- BS EN 7396-1 Pipelines for Compressed medical Gases and Vacuum
- BS EN 7396-2 Anaesthetic Gas Scavenging Disposal Systems
- BS EN 9170-1 Terminal Units for use with Compressed Medical Gases and Vacuum
- BS EN 9170-2 Terminal Units for Anaesthetic Gas Scavenging Systems
- C11 NHS Model Engineering Specification – Medical Gases
- BS EN 18082 Non-interchangeable Screw Threaded (NIST) Low-pressure Connectors for Medical Gases
- BS 5682 Specification for Probes Specification for Probes (quick connectors) for Medical Gases.
- Medical Device Directive 93/42/EEC (CE0086) Class IIb.
- DIN 13260-2 Part 2: Dimensions and allocation of Probes and Gas specific connection points for Terminal Units
- Available for Oxygen, Nitrous Oxide, Medical Air, CO2, Motor Air and Vacuum (other gases available on request)
- Incorporating a 12mm copper stub pipe to EN 13348 to allow easy connection to the Medical Gas Pipeline system, other options include NIST or DISS type fittings for pendants or bed head units.
- Probe insertion design incorporates parking position and full insert for 100% operation, each outlet is supplied with Flush/Surface Box or Bed Head Plate mounting options and include a 3-year warranty.
- CE marked CE0086 Class IIb Medical Device.
Medical Vacuum Plant British Standard
me British Standard
Precision UK’s CPX Medical Vacuum Plant British Standard is manufactured under BS EN 13485 Medical Devices: Quality Management Systems. It provides a centralized source of vacuum, available in simplex to multi-pump configurations dependent on individual requirement, to include complete package plant or modular format.
Specification: -
Specific Benefits Include
- Fully complies to HTM 02-01, HTM 2022, C11, BS EN 7396, CE0086 Class IIb
- CE marked under Medical Device Directive 93/42/EEC
- CPX® branded solid British design
- Control and highly visible indication panel
- All interconnecting pipework is included
- Outlet pipework for connecting to the pipeline
- Anti-vibration mounts on all pumps
- Isolator to each pump unit as standard
- Alarm and BMS outputs for remote status indication
- Digital display available on request
- All settings are factory set and verified with certificates of inspection
- Each plant has a full warranty of 12 months from its commission date
- Options – Touchscreen, BMS Modbus, Digital Outputs, SMS Texting Alarms, Service Reminders
Oxygen Automatic Manifold
Oxygen Automatic Manifold
Oxygen Automatic Manifold is mainly suitable for continuous consumption of bottled oxygen hospital. In use, the number of or even dozens of oxygen cylinders are centrally connected to the manifold pipe. The gas is filtered, decompression and pressure stabilized, and transported to the use site. AmcareMed Medical Automatic Gas Manifold is fully automatic and has pressure regulators with LED Display. Pressure unit provides a bar, Mpa or psi for measurement conversion. The fully automatic manifold system monitors cylinder tank pressure electronically, automatically changes over to the secondary tank when the primary cylinder tank is depleted and eliminates the need to manually set a priority side. The solenoid valve technology allows us to eliminate the shuttle valve and it can be realized automatically switch do not need operator debugging. In the electrical system power state, it can maintain continuous supply medical gas. It’s economical and efficient for hospital medical gas pipeline system. Our automatic gas manifold is divided according to the number of cylinders and configuration, with a variety of structural forms, 2 * 1 cylinder group, 2 * 2 cylinder group, 2 * 3 cylinder group, 2 * 4 cylinder group, 2 * 5 cylinder group for selection, but also according to user needs and environmental requirements for special configuration.Specification:
- LED Display full automatic manifold
- Closed box without interference
- Stainless steel diaphragm reducer, better to control flow
- With alarm system and remote alarming
- Open design to meet requirements for expansion in future
- Sustainable supply and control circuit when the power failure
- Input: 15Mpa, output: 200m3/h,0.4-0.8Mpa
- Input/output signal: 4–20mA, 485 bus communication
- Wall or floor mounts available
- 100% pressure test, safe and reliable