Touch Screen Patient Monitor MD9015
Touch Screen Patient Monitor MD9015
Touch Screen Patient Monitor MD9015 is a touch screen 15 inch patient monitor by Meditech 192-hour trend graph,1000 group of blood pressure list,ST segment measurements, arrhythmia analysis and more functions, Support up to 32 TCP/IP network connection,composed of a central information system..
Comes with remote control.
Please see our complete range of Patient Monitor & Multiparameter Monitors
Features:
- 5” high resolution color TFT display with maximum 13 waveforms
- Full touch-screen enables intuitive operation by clicking on the specific parameters of the waveform in real time, standard configuration includes the navigation knob
- Pacemaker detection, electrosurgical interference proof
- Defibrillation protection and defibrillation synchronization
- SD Card slot enable memory extension for large data storage
- USB and serial port enable abundant future upgrades
- VGA output and Analog output
- OxyCRG available to judge the respiration and circulation function for neonate
- Large font display
- Arrhythmia and S-T segment analysis
- Built-in rechargeable Li-ion (6hours maximum with 2x 4200mAh batteries)
- Nurse Call function and bi-directional communication with MFM-CMS central station
- Multi language: English/Simplified Chinese/Traditional
- Chinese/Spanish/Czech/Italian/Polish/French/German/Brazilian/Portugese/Russian.
- Standard configuration: 3/5-lead ECG, NIBP, SpO2, RESP, 2-Temp, PR
- Optional: 12-lead ECG, Nellcor-SpO2, Omron NIBP, 2-IBP/4-IBP, Mainstream/Side stream CO2,
- CO, Multi-Gas, Full Touch Screen, Thermal Recorder, WLAN Accessory
- Large Data Storage: 120 hours graphic and tabular trends of all parameters; 1200 sets of NIBP
- measurement and 70 alarm events; 2-USB ports and SC card slot ensure data storage/function upgrades.
- Clinical data can be viewed and managed via Patientcare viewer software (To be released)
- Clinical network: bi-directional communication with CMS-2000 central station by wired or wireless connection,
- Complete and flexible mounting solution for ICU and operation room. High-end parameters for more flexible clinical applications.
Options:
- Invasive Blood Pressure (IBP)
- Carbon dioxide (CO2) Module
- Masimo SpO2 Module
- Thermal Printer
Touch Screen Patient Monitor MD9015
Specification:
Electrocardiogram (ECG)
- Input mode Five-lead ECG input / three-lead ECG input
- Lead selection I, II, III, aVR, aVL, aVF, V-
- Gain selection AUTO,0.25X,0.5X,1X,2X,4X
- Operating mode Diagnostic mode, monitoring mode, operation mode
- Calibration signal 1mV ±5%
- Protection The isolation voltage 4000V, 50/60Hz. Anti-high-frequency interference of electric knife.
- Anti-defibrillation protection.
- Pacemaker at the same time use Support
- Electrode off instructions Each electrode (RL excluded)
- Scanning speed 12.5mm/s, 25 mm/s, 50 mm/s
- Common mode rejection ratio ≥90dB
- Input impedance ≥5.0MΩ
Heartrate (HR)
- Measuring range Adult 30 ~ 300bpm, newborns 30 to 350 bpm
- Resolution 1 bpm
- Accuracy < ±5bpm
- Heart rate sensitivity ≥0.20mVp-p
- Alarm range 15 to 350 bpm, upper and lower limits
- Alarm indication Audible and visual alarm, display the data and parameters flashing display alarm
message text prompts, there are three levels of alarm
Pulse Oximetry
- SPO2 Range: 1% to 99%
- Resolution: 1%
- Accuracy: 70% to 99% range: ±2%;
- 1% to 69% range: ±5%;
- Method: Dual wavelength LED
ST-segment
- ST-segment measurement range -2.0~+2.0mV
- ST-segment measurement accuracy Within the range of -0.8 ~ +0.8 mV: ± 0.02mV or reading± 10%,
Whichever is greater; Other range: undefined - Resolution 0.01mV
- ST-segment update cycle 10s
- ST segment alarm range -2.0 ~ +2.0 MV, the upper and lower limits continuously adjustable
Arrhythmia analysis
- Arrhythmia types 13 kinds of (scalable)
- Respiration Rate
- Rate: 2 to 120 bpm (CO2)
Resolution: 1 breath/min
NIBP (Non-invasive Blood Pressure)
- Technique: Oscillometric during inflation
- Range: Adult/Pediatric: 40 to 240 mmHg
- Neonate: 10 to 150 mmHg
- Measurement Cycle: < 40 sec. typical
Automatic Measurement
- Cycles (Selectable): 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr
- STAT Mode: 5 minutes of continuous readings
- Max. Allowable Cuff
- Pressure: Adult: 300mmHg
- Pediatric: 240 mmHg;
- Neonate: 150 mmHg
- Resolution: 1 mmHg
- Transducer Accuracy: ±2 mmHg or ±2% of reading,
- Heart (Pulse) Rate
- Range: 30 to 250 bpm
- Accuracy: ±2 bpm or ±3%, whichever is greater
EtCO2 technological index
- Interface form External interface
Range of - measurement 0~10 kPa or (0~75) mmHg
- precision(error) (0kPa~5.4kPa) the error is ±0.3kPa、
- (5.5kPa~10.0kPa)the error is ±0.7kPa
- Alarm upper limit 2.1~13.2 kPa
- Alarm lower limit 0~6.5 kPa
- time 12s
- EtCO2 exist
- Unit kPa / mmHg / %
- Compatibility
- external main stream and side stream are compatible
IBP technological index
Measured channel Single way and double way are optional
Range of
measurement SYS: 6.7kPa~32.0kPa(50mmHg~240mmHg)
MEAN: 3.4kPa~26.6kPa(26mmHg~200mmHg)
DIA: 2.9kPa~24.0kPa(22mmHg~180mmHg)
Mean error ≤±0.4kPa (±3mmHg)
Range of alarm SYS: upper limit 0.3kPa~53.3kPa(2mmHg~400mmHg)
Lower limit 0kPa~53.1kPa(0mmHg~398mmHg)
MEAN: upper limit 0.3kPa~53.3kPa (2mmHg~400mmHg)
Lower limit 0kPa~53.1kPa (0mmHg~398mmHg)
DIA: upper limit 0.3kPa~53.3kPa ( 2mmHg~400mmHg)
Lower limit 0kPa~53.1kPa ( 0mmHg~398mmHg)
Measured unit mmHg/kPa
Specification of
sensor DPT-248(space)
Consumables mode SCW-UTAH-01
Touch Screen Patient Monitor MD9015
Touch Screen Patient Monitor MD9015 is a touch screen 15 inch patient monitor by Meditech 192-hour trend graph,1000 group of blood pressure list,ST segment measurements, arrhythmia analysis and more functions, Support up to 32 TCP/IP network connection,composed of a central information system..
Comes with remote control.
Please see our complete range of Patient Monitor & Multiparameter Monitors
Features:
- 5” high resolution color TFT display with maximum 13 waveforms
- Full touch-screen enables intuitive operation by clicking on the specific parameters of the waveform in real time, standard configuration includes the navigation knob
- Pacemaker detection, electrosurgical interference proof
- Defibrillation protection and defibrillation synchronization
- SD Card slot enable memory extension for large data storage
- USB and serial port enable abundant future upgrades
- VGA output and Analog output
- OxyCRG available to judge the respiration and circulation function for neonate
- Large font display
- Arrhythmia and S-T segment analysis
- Built-in rechargeable Li-ion (6hours maximum with 2x 4200mAh batteries)
- Nurse Call function and bi-directional communication with MFM-CMS central station
- Multi language: English/Simplified Chinese/Traditional
- Chinese/Spanish/Czech/Italian/Polish/French/German/Brazilian/Portugese/Russian.
- Standard configuration: 3/5-lead ECG, NIBP, SpO2, RESP, 2-Temp, PR
- Optional: 12-lead ECG, Nellcor-SpO2, Omron NIBP, 2-IBP/4-IBP, Mainstream/Side stream CO2,
- CO, Multi-Gas, Full Touch Screen, Thermal Recorder, WLAN Accessory
- Large Data Storage: 120 hours graphic and tabular trends of all parameters; 1200 sets of NIBP
- measurement and 70 alarm events; 2-USB ports and SC card slot ensure data storage/function upgrades.
- Clinical data can be viewed and managed via Patientcare viewer software (To be released)
- Clinical network: bi-directional communication with CMS-2000 central station by wired or wireless connection,
- Complete and flexible mounting solution for ICU and operation room. High-end parameters for more flexible clinical applications.
Options:
- Invasive Blood Pressure (IBP)
- Carbon dioxide (CO2) Module
- Masimo SpO2 Module
- Thermal Printer
Touch Screen Patient Monitor MD9015
Specification:
Electrocardiogram (ECG)
- Input mode Five-lead ECG input / three-lead ECG input
- Lead selection I, II, III, aVR, aVL, aVF, V-
- Gain selection AUTO,0.25X,0.5X,1X,2X,4X
- Operating mode Diagnostic mode, monitoring mode, operation mode
- Calibration signal 1mV ±5%
- Protection The isolation voltage 4000V, 50/60Hz. Anti-high-frequency interference of electric knife.
- Anti-defibrillation protection.
- Pacemaker at the same time use Support
- Electrode off instructions Each electrode (RL excluded)
- Scanning speed 12.5mm/s, 25 mm/s, 50 mm/s
- Common mode rejection ratio ≥90dB
- Input impedance ≥5.0MΩ
Heartrate (HR)
- Measuring range Adult 30 ~ 300bpm, newborns 30 to 350 bpm
- Resolution 1 bpm
- Accuracy < ±5bpm
- Heart rate sensitivity ≥0.20mVp-p
- Alarm range 15 to 350 bpm, upper and lower limits
- Alarm indication Audible and visual alarm, display the data and parameters flashing display alarm
message text prompts, there are three levels of alarm
Pulse Oximetry
- SPO2 Range: 1% to 99%
- Resolution: 1%
- Accuracy: 70% to 99% range: ±2%;
- 1% to 69% range: ±5%;
- Method: Dual wavelength LED
ST-segment
- ST-segment measurement range -2.0~+2.0mV
- ST-segment measurement accuracy Within the range of -0.8 ~ +0.8 mV: ± 0.02mV or reading± 10%,
Whichever is greater; Other range: undefined - Resolution 0.01mV
- ST-segment update cycle 10s
- ST segment alarm range -2.0 ~ +2.0 MV, the upper and lower limits continuously adjustable
Arrhythmia analysis
- Arrhythmia types 13 kinds of (scalable)
- Respiration Rate
- Rate: 2 to 120 bpm (CO2)
Resolution: 1 breath/min
NIBP (Non-invasive Blood Pressure)
- Technique: Oscillometric during inflation
- Range: Adult/Pediatric: 40 to 240 mmHg
- Neonate: 10 to 150 mmHg
- Measurement Cycle: < 40 sec. typical
Automatic Measurement
- Cycles (Selectable): 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr
- STAT Mode: 5 minutes of continuous readings
- Max. Allowable Cuff
- Pressure: Adult: 300mmHg
- Pediatric: 240 mmHg;
- Neonate: 150 mmHg
- Resolution: 1 mmHg
- Transducer Accuracy: ±2 mmHg or ±2% of reading,
- Heart (Pulse) Rate
- Range: 30 to 250 bpm
- Accuracy: ±2 bpm or ±3%, whichever is greater
EtCO2 technological index
- Interface form External interface
Range of - measurement 0~10 kPa or (0~75) mmHg
- precision(error) (0kPa~5.4kPa) the error is ±0.3kPa、
- (5.5kPa~10.0kPa)the error is ±0.7kPa
- Alarm upper limit 2.1~13.2 kPa
- Alarm lower limit 0~6.5 kPa
- time 12s
- EtCO2 exist
- Unit kPa / mmHg / %
- Compatibility
- external main stream and side stream are compatible
IBP technological index
Measured channel Single way and double way are optional
Range of
measurement SYS: 6.7kPa~32.0kPa(50mmHg~240mmHg)
MEAN: 3.4kPa~26.6kPa(26mmHg~200mmHg)
DIA: 2.9kPa~24.0kPa(22mmHg~180mmHg)
Mean error ≤±0.4kPa (±3mmHg)
Range of alarm SYS: upper limit 0.3kPa~53.3kPa(2mmHg~400mmHg)
Lower limit 0kPa~53.1kPa(0mmHg~398mmHg)
MEAN: upper limit 0.3kPa~53.3kPa (2mmHg~400mmHg)
Lower limit 0kPa~53.1kPa (0mmHg~398mmHg)
DIA: upper limit 0.3kPa~53.3kPa ( 2mmHg~400mmHg)
Lower limit 0kPa~53.1kPa ( 0mmHg~398mmHg)
Measured unit mmHg/kPa
Specification of
sensor DPT-248(space)
Consumables mode SCW-UTAH-01
You must be logged in to post a review.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
12 Channel ECG Cardio7 Bionet
12 Channel ECG Cardio7 Bionet
12 Channel ECG Cardio7 Bionet device is classified as follows, in accordance with IEC60601-1. There are a lot of ECG Machines in the market but the reputation of Bionet is absolutely phenomenal, please bear in mind that Bionet is USA Based company but the products are manufactured in Korea. However each and every single product is FDA Approved. 12 Channel ECG Cardio7 Bionet device or system is suitable for use in all establishments other than domestic and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. Mains power should be a typical commercial or hospital environment. For more information regarding the product please feel free to contact us.CLICK HERE TO DOWNLOAD THE CATALOG Bionet Cardio7_ECG.pdf
Features:
12 channel interpretive ECG for adult, pediatric and neonatal use over 130 kinds of interpretation results based on advanced Minnesota code, HRV (Hearth Rate Variability analysis)- memory for up to 200 patients
- real-time preview monitor
- PC compatible through LAN or Wi-Fi
- multi-Ianguage selectable software (GB, RU, FR, DE, IT, CN, ES, TU, PL, RU, PT)
- lead fault message
- pace maker detection
- automatic arrhythmia detection
- 3, 5, 10 minutes long term recording
- grid function allows you to use low cost plain fax paper
- wide and clear colour 7” TFT LCD (800x480)
- touch screen for easy operation
- full disclosure function
Specification:
ECG leads: 10 lead, 12 channel simultaneous ECG and acquisition • Dimension: 300(W) x 299(H) x 123(D)mm, approx. 3.5 kg • Recording channel: 3 channels + 1 rhythm, 3 channels + 3 rhythm, 6 channels + 1 rhythm, 12 channels, 60 seconds 1 channel, 3, 5, 10 minutes 1 channel and beat report • Sensitivity: 2.5, 5, 10, 20, auto (l~aVF: 10, V1~V6: 5) mm/mV • Printing speed: 5, 12.5, 25, 50, 100 mm/s • Sampling rate: 2,000 samples/sec • Filters: AC (50/60 Hz, -20 dB or better) • Muscle (25~35 Hz, -3dB or better) • Base line drift (0.05, 0.1, 0.2 Hz, -3dB or better) • Low pass filter: off, 40 Hz, 100 Hz, 150 Hz • Display: 7" color TFT LCD display (800x480), 12 channels preview ECG wave • Monitor display: ID, date, sensitivity, speed, filter, form, rhythm lead • User interface: Touch screen (alphanumeric and symbol available), Keyboard, rotary push-knob (pop-up menu) • Patient data: ID, name, age, sex, height, weight, smoke, race • Basic measurement: Heart rate, PR int, QRS dur, QT/QTc, P-R-T axis • Recorder: Thermal print head, roll paper, A4 report paper: 210x300 mm (8.5"x11") • Resolution: - Vertical: 8 dot/mm - Horizontal: 16 dot/mm • Electrical: - Internal noise: 20 µV (p-p) max - Input circuit: floating input - Input impedance: =50 MO - Input voltage range: = ±5 mV - Common mode rejection: > 105 dB - DC offset voltage: = ±400 mV - Time constant: 3.2 sec - Patient leakage current: < 10 µA - Frequency response: 0.05 ~150 Hz - Isolated and defibrillation protected • Signal quality control: Disconnected lead detection, Pacemaker pulse detection • ECG data storage: storage for 200 ECGs (Internal on flash memory) • Power: 100~240 VAC, 50/60 Hz or battery (option) 2.0~1.0 A, 60 VA max • Battery (Li-Ion): 4 hours of normal use (approx.200 ECG printouts) • Communication: PC connection with LAN D2 Wi-Fi • Safety conformity: Class I, Type CF, CE, CSA, FDA, KFDA, CFDA, CCC General Information of 12 Channel ECG Cardio7 Bionet For more information regarding ecg machine price in Pakistan, 3 channel ecg machine price in Pakistan or 12 channel ecg price in Pakistan please feel free to contact us. Our technical staff will provide you full back-up and support in all over Pakistan. When talk about ecg price in Pakistan or ecg machine price in Pakistan we are the number one company in entire Pakistan to provide ECG Machines in Pakistan, ETT Machines in Pakistan, Patient Monitors in Pakistan, Cardiac Monitors in Pakistan, AED in Pakistan, Defibrillator in Pakistan and almost all type of Cardiology Equipment in Pakistan.Blood Pressure Apparatus M2
Blood Pressure Apparatus M2
Blood Pressure Apparatus M2 allows you comfortably, quickly and accurately check your blood pressure and monitor your results easily. Monitoring is made easy with the fully automatic digital OMRON M2 which features Intellisense Technology for soft cuff inflation. It is so easy to use you can take readings with just one touch. Features and cautions Intellisense Technology - this unique OMRON technology ensures that there is less discomfort from over-inflation of the cuff. Helps you take your blood pressure quickly and easily with one touch operation. Included cuff fits arms with a circumference of 22 - 32 cm. Specification:- Device Type: Upper Arm Blood Pressure Monitor
- Cuff Type: Medium Cuff 22-32cm
- Memory: 30 Readings
- Cuff Wrap Guide: Yes
- Blood Pressure Level Indicator: Yes
- Irregular Heart Beat Detection: Yes
- Storage Case Included: Yes
- Validation Type: Clinical Validation
- Intellisense Technology: Yes
- Stroke Prevention: Yes
- Length cm: 12.50
- Height cm: 16.50
- Depth cm: 12.00
- M2 blood pressure monitor
- Cuff
- Instruction Manual
- Blood Pressure Pass
- Batteries and Storage case
Mindray Hematology Analyzer BC-10
Mindray Hematology Analyzer BC-10
Mindray Hematology Analyzer BC-10 is undoubtedly reliable Hematology Analyzer in Pakistan and worldwide. It has Impedance method for WBC, RBC and PLT counting Cyanide free reagent for hemoglobin test. Now in order to conduct 1000 tests 02 Diluent and 01 Lyse maybe used. When we talk about Mindray Hematology Analyzer BC-10 it does not lost testing procedure and you can conduct as much tests as you can conduct on a one go.Technical Specifications:
Principles : Impedance method for WBC, RBC and PLT counting Cyanide free reagent for hemoglobin test. Parameters: 20 parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR 3 histograms for WBC, RBC and PLT 2 research parameters: NLR, PLR Sample Volume: Prediluted mode ≤20μL Whole blood mode ≤9 μL CLICK HERE TO DOWNLOAD THE CATALOG OF MINDRAY BC-10.pdf General Information: Mindray Hematology Analyzer BC-10 has advanced detailed flag information provides warning in case of abnormal cell results. High quality original reagent calibrator and quality controls maintain your work at a high level. We integrate technologies into our products to fulfill your clinical needs, therefore, today, Mindray products and services are used by healthcare facilities in over 190 countries and regions. More and more customers choose Mindray products and trust Mindray's quality. Mindray Hematology Analyzer BC-10 Quality and user experience are top priorities for Mindray. We design and manage our manufacturing processes in compliance with FDA, ISO and CE. Complete quality control systems in Mindray's manufacturing centers ensure we exceed the most stringent criteria and traceability throughout the entire process. Our professional and responsive support team makes sure your systems are kept at full capability Zirar Enterprises are the distributor of mindray in Pakistan, when we talk about the Hematology Analyzer price in Pakistan, we have one the best discounted options and Mindray Hematology Analyzer BC-10 is our bestseller. CLICK HERE TO SEE Auto Hematology Analyzer RT-7600 For more information, questions and queries please feel free to contact us +923224602203 or Email: zirarenterprises@gmail.com, info@ziarenterprises.comPatient Monitor Operon OM12
Patient Monitor Operon OM12
Specification:- 12" inched LCD Monitor with high brightness TFT colors
- VGA slot available for attaching high resolution screen such as LED's, Monitors Etc
- SPO2
- Alarm/Beep as per prescribed statistics of the patient
- Accurate Blood Pressure display.
- Heart Beat display
- Printable ECH and other statistics/diagnosis.