Touch Screen Patient Monitor MD9015
Touch Screen Patient Monitor MD9015 is a touch screen 15 inch patient monitor by Meditech 192-hour trend graph,1000 group of blood pressure list,ST segment measurements, arrhythmia analysis and more functions, Support up to 32 TCP/IP network connection,composed of a central information system..
Comes with remote control.
Please see our complete range of Patient Monitor & Multiparameter Monitors
Features:
- 5” high resolution color TFT display with maximum 13 waveforms
- Full touch-screen enables intuitive operation by clicking on the specific parameters of the waveform in real time, standard configuration includes the navigation knob
- Pacemaker detection, electrosurgical interference proof
- Defibrillation protection and defibrillation synchronization
- SD Card slot enable memory extension for large data storage
- USB and serial port enable abundant future upgrades
- VGA output and Analog output
- OxyCRG available to judge the respiration and circulation function for neonate
- Large font display
- Arrhythmia and S-T segment analysis
- Built-in rechargeable Li-ion (6hours maximum with 2x 4200mAh batteries)
- Nurse Call function and bi-directional communication with MFM-CMS central station
- Multi language: English/Simplified Chinese/Traditional
- Chinese/Spanish/Czech/Italian/Polish/French/German/Brazilian/Portugese/Russian.
- Standard configuration: 3/5-lead ECG, NIBP, SpO2, RESP, 2-Temp, PR
- Optional: 12-lead ECG, Nellcor-SpO2, Omron NIBP, 2-IBP/4-IBP, Mainstream/Side stream CO2,
- CO, Multi-Gas, Full Touch Screen, Thermal Recorder, WLAN Accessory
- Large Data Storage: 120 hours graphic and tabular trends of all parameters; 1200 sets of NIBP
- measurement and 70 alarm events; 2-USB ports and SC card slot ensure data storage/function upgrades.
- Clinical data can be viewed and managed via Patientcare viewer software (To be released)
- Clinical network: bi-directional communication with CMS-2000 central station by wired or wireless connection,
- Complete and flexible mounting solution for ICU and operation room. High-end parameters for more flexible clinical applications.
Options:
- Invasive Blood Pressure (IBP)
- Carbon dioxide (CO2) Module
- Masimo SpO2 Module
- Thermal Printer
Touch Screen Patient Monitor MD9015
Specification:
Electrocardiogram (ECG)
- Input mode Five-lead ECG input / three-lead ECG input
- Lead selection I, II, III, aVR, aVL, aVF, V-
- Gain selection AUTO,0.25X,0.5X,1X,2X,4X
- Operating mode Diagnostic mode, monitoring mode, operation mode
- Calibration signal 1mV ±5%
- Protection The isolation voltage 4000V, 50/60Hz. Anti-high-frequency interference of electric knife.
- Anti-defibrillation protection.
- Pacemaker at the same time use Support
- Electrode off instructions Each electrode (RL excluded)
- Scanning speed 12.5mm/s, 25 mm/s, 50 mm/s
- Common mode rejection ratio ≥90dB
- Input impedance ≥5.0MΩ
Heartrate (HR)
- Measuring range Adult 30 ~ 300bpm, newborns 30 to 350 bpm
- Resolution 1 bpm
- Accuracy < ±5bpm
- Heart rate sensitivity ≥0.20mVp-p
- Alarm range 15 to 350 bpm, upper and lower limits
- Alarm indication Audible and visual alarm, display the data and parameters flashing display alarm
message text prompts, there are three levels of alarm
Pulse Oximetry
- SPO2 Range: 1% to 99%
- Resolution: 1%
- Accuracy: 70% to 99% range: ±2%;
- 1% to 69% range: ±5%;
- Method: Dual wavelength LED
ST-segment
- ST-segment measurement range -2.0~+2.0mV
- ST-segment measurement accuracy Within the range of -0.8 ~ +0.8 mV: ± 0.02mV or reading± 10%,
Whichever is greater; Other range: undefined - Resolution 0.01mV
- ST-segment update cycle 10s
- ST segment alarm range -2.0 ~ +2.0 MV, the upper and lower limits continuously adjustable
Arrhythmia analysis
- Arrhythmia types 13 kinds of (scalable)
- Respiration Rate
- Rate: 2 to 120 bpm (CO2)
Resolution: 1 breath/min
NIBP (Non-invasive Blood Pressure)
- Technique: Oscillometric during inflation
- Range: Adult/Pediatric: 40 to 240 mmHg
- Neonate: 10 to 150 mmHg
- Measurement Cycle: < 40 sec. typical
Automatic Measurement
- Cycles (Selectable): 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr
- STAT Mode: 5 minutes of continuous readings
- Max. Allowable Cuff
- Pressure: Adult: 300mmHg
- Pediatric: 240 mmHg;
- Neonate: 150 mmHg
- Resolution: 1 mmHg
- Transducer Accuracy: ±2 mmHg or ±2% of reading,
- Heart (Pulse) Rate
- Range: 30 to 250 bpm
- Accuracy: ±2 bpm or ±3%, whichever is greater
EtCO2 technological index
- Interface form External interface
Range of - measurement 0~10 kPa or (0~75) mmHg
- precision(error) (0kPa~5.4kPa) the error is ±0.3kPa、
- (5.5kPa~10.0kPa)the error is ±0.7kPa
- Alarm upper limit 2.1~13.2 kPa
- Alarm lower limit 0~6.5 kPa
- time 12s
- EtCO2 exist
- Unit kPa / mmHg / %
- Compatibility
- external main stream and side stream are compatible
IBP technological index
Measured channel Single way and double way are optional
Range of
measurement SYS: 6.7kPa~32.0kPa(50mmHg~240mmHg)
MEAN: 3.4kPa~26.6kPa(26mmHg~200mmHg)
DIA: 2.9kPa~24.0kPa(22mmHg~180mmHg)
Mean error ≤±0.4kPa (±3mmHg)
Range of alarm SYS: upper limit 0.3kPa~53.3kPa(2mmHg~400mmHg)
Lower limit 0kPa~53.1kPa(0mmHg~398mmHg)
MEAN: upper limit 0.3kPa~53.3kPa (2mmHg~400mmHg)
Lower limit 0kPa~53.1kPa (0mmHg~398mmHg)
DIA: upper limit 0.3kPa~53.3kPa ( 2mmHg~400mmHg)
Lower limit 0kPa~53.1kPa ( 0mmHg~398mmHg)
Measured unit mmHg/kPa
Specification of
sensor DPT-248(space)
Consumables mode SCW-UTAH-01