Automated External Defibrillator AED Defibrillator Rescue Sam, progetti Italy helps tackle Sudden cardiac arrest (SCA) associated with ventricular fibrillation (VF) remains a leading cause of unexpected death in the Western world. It has been estimated that chances for survival from SCA decrease approximately 7% to 10% with each passing minute and that survival rates after 12 minutes are only 2% to 5%. The most common cause of SCA is ventricular fibrillation (VF), a lethal heart
rhythm, and survival depends on the rapid treatment called defibrillation, an electrical shock sent to the heart to resume normal and healthy rhythm. So early defibrillation is the sole definitive determinant of survival and is the key factor in cardiopulmonary resuscitation. Currently, fewer than 5% of the 60.000 persons who experience out-of-hospital cardiac arrest each year survival to hospital discharge.
Specification:
AED Defibrillator Rescue Sam, Progetti, Italy
Shockable rhythms: fibrillation and/or tachycardia
Not Shockable rhythms: different from VF and VT
Waveform: BTE (biphasic truncated exponential)
Impedance: compesated
Guide Lines: AAMI DF39 2010 / AHA 2010
Shock Energy Accuracy: according to IEC EN60601-2-4
Patient Isolation: type BF
Impedance: 25 – 175 Ώ
OPERATING MODE: Semi Automatic
ENERGY: 200 j Fixed as new guidelines AHA 2010
PROTOCOL: Voice prompts and indicators guide user through protocol
CHARGE CONTROL: automatic by software
CHARGE TIME from Shock Advised: < 8 Sec, typical with new battery
CONTROLS: Shock button, info-button, On/Off Button
INDICATORS: 6 Leds and 3 scenarios
WEIGHT: 2,2 Kg with battery pack installed
SELF TEST: automatic and user activated
Optional special adapter pack for data transmission to PC via USB
– Data Stored: first 60 minutes of ECG and the entire incident’s events and
analysis decisions
– PC Software for Data Management
BATTERY
-Type: 12 Volt DC, 4,2 Ah, Lithium manganese dioxide, long life
-Model number: ELRS-002
-Capacity: min 200 shocks or 4 hours of operating time continuously
-Shelf life: typically 5 years (prior to installation)
-Standby life: typically 5 years (after installation)
-Don’t install battery packs after the expiration date the battery is not rechargeable
-Don’t immerse battery pack into the water or other liquids
AED Defibrillator Rescue Sam, Progetti, Italy
Automated External Defibrillator AED Defibrillator Rescue Sam, progetti Italy helps tackle Sudden cardiac arrest (SCA) associated with ventricular fibrillation (VF) remains a leading cause of unexpected death in the Western world. It has been estimated that chances for survival from SCA decrease approximately 7% to 10% with each passing minute and that survival rates after 12 minutes are only 2% to 5%. The most common cause of SCA is ventricular fibrillation (VF), a lethal heart
rhythm, and survival depends on the rapid treatment called defibrillation, an electrical shock sent to the heart to resume normal and healthy rhythm. So early defibrillation is the sole definitive determinant of survival and is the key factor in cardiopulmonary resuscitation. Currently, fewer than 5% of the 60.000 persons who experience out-of-hospital cardiac arrest each year survival to hospital discharge.
Specification:
AED Defibrillator Rescue Sam, Progetti, Italy
Shockable rhythms: fibrillation and/or tachycardia
Not Shockable rhythms: different from VF and VT
Waveform: BTE (biphasic truncated exponential)
Impedance: compesated
Guide Lines: AAMI DF39 2010 / AHA 2010
Shock Energy Accuracy: according to IEC EN60601-2-4
Patient Isolation: type BF
Impedance: 25 – 175 Ώ
OPERATING MODE: Semi Automatic
ENERGY: 200 j Fixed as new guidelines AHA 2010
PROTOCOL: Voice prompts and indicators guide user through protocol
CHARGE CONTROL: automatic by software
CHARGE TIME from Shock Advised: < 8 Sec, typical with new battery
CONTROLS: Shock button, info-button, On/Off Button
INDICATORS: 6 Leds and 3 scenarios
WEIGHT: 2,2 Kg with battery pack installed
SELF TEST: automatic and user activated
Optional special adapter pack for data transmission to PC via USB
– Data Stored: first 60 minutes of ECG and the entire incident’s events and
analysis decisions
– PC Software for Data Management
BATTERY
-Type: 12 Volt DC, 4,2 Ah, Lithium manganese dioxide, long life
-Model number: ELRS-002
-Capacity: min 200 shocks or 4 hours of operating time continuously
-Shelf life: typically 5 years (prior to installation)
-Standby life: typically 5 years (after installation)
-Don’t install battery packs after the expiration date the battery is not rechargeable
-Don’t immerse battery pack into the water or other liquids
You must be logged in to post a review.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
12 Channel ECG Cardio7 Bionet
12 Channel ECG Cardio7 Bionet
12 Channel ECG Cardio7 Bionet device is classified as follows, in accordance with IEC60601-1. There are a lot of ECG Machines in the market but the reputation of Bionet is absolutely phenomenal, please bear in mind that Bionet is USA Based company but the products are manufactured in Korea. However each and every single product is FDA Approved. 12 Channel ECG Cardio7 Bionet device or system is suitable for use in all establishments other than domestic and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. Mains power should be a typical commercial or hospital environment. For more information regarding the product please feel free to contact us.CLICK HERE TO DOWNLOAD THE CATALOG Bionet Cardio7_ECG.pdf
Features:
12 channel interpretive ECG for adult, pediatric and neonatal use over 130 kinds of interpretation results based on advanced Minnesota code, HRV (Hearth Rate Variability analysis)- memory for up to 200 patients
- real-time preview monitor
- PC compatible through LAN or Wi-Fi
- multi-Ianguage selectable software (GB, RU, FR, DE, IT, CN, ES, TU, PL, RU, PT)
- lead fault message
- pace maker detection
- automatic arrhythmia detection
- 3, 5, 10 minutes long term recording
- grid function allows you to use low cost plain fax paper
- wide and clear colour 7” TFT LCD (800x480)
- touch screen for easy operation
- full disclosure function
Specification:
ECG leads: 10 lead, 12 channel simultaneous ECG and acquisition • Dimension: 300(W) x 299(H) x 123(D)mm, approx. 3.5 kg • Recording channel: 3 channels + 1 rhythm, 3 channels + 3 rhythm, 6 channels + 1 rhythm, 12 channels, 60 seconds 1 channel, 3, 5, 10 minutes 1 channel and beat report • Sensitivity: 2.5, 5, 10, 20, auto (l~aVF: 10, V1~V6: 5) mm/mV • Printing speed: 5, 12.5, 25, 50, 100 mm/s • Sampling rate: 2,000 samples/sec • Filters: AC (50/60 Hz, -20 dB or better) • Muscle (25~35 Hz, -3dB or better) • Base line drift (0.05, 0.1, 0.2 Hz, -3dB or better) • Low pass filter: off, 40 Hz, 100 Hz, 150 Hz • Display: 7" color TFT LCD display (800x480), 12 channels preview ECG wave • Monitor display: ID, date, sensitivity, speed, filter, form, rhythm lead • User interface: Touch screen (alphanumeric and symbol available), Keyboard, rotary push-knob (pop-up menu) • Patient data: ID, name, age, sex, height, weight, smoke, race • Basic measurement: Heart rate, PR int, QRS dur, QT/QTc, P-R-T axis • Recorder: Thermal print head, roll paper, A4 report paper: 210x300 mm (8.5"x11") • Resolution: - Vertical: 8 dot/mm - Horizontal: 16 dot/mm • Electrical: - Internal noise: 20 µV (p-p) max - Input circuit: floating input - Input impedance: =50 MO - Input voltage range: = ±5 mV - Common mode rejection: > 105 dB - DC offset voltage: = ±400 mV - Time constant: 3.2 sec - Patient leakage current: < 10 µA - Frequency response: 0.05 ~150 Hz - Isolated and defibrillation protected • Signal quality control: Disconnected lead detection, Pacemaker pulse detection • ECG data storage: storage for 200 ECGs (Internal on flash memory) • Power: 100~240 VAC, 50/60 Hz or battery (option) 2.0~1.0 A, 60 VA max • Battery (Li-Ion): 4 hours of normal use (approx.200 ECG printouts) • Communication: PC connection with LAN D2 Wi-Fi • Safety conformity: Class I, Type CF, CE, CSA, FDA, KFDA, CFDA, CCC General Information of 12 Channel ECG Cardio7 Bionet For more information regarding ecg machine price in Pakistan, 3 channel ecg machine price in Pakistan or 12 channel ecg price in Pakistan please feel free to contact us. Our technical staff will provide you full back-up and support in all over Pakistan. When talk about ecg price in Pakistan or ecg machine price in Pakistan we are the number one company in entire Pakistan to provide ECG Machines in Pakistan, ETT Machines in Pakistan, Patient Monitors in Pakistan, Cardiac Monitors in Pakistan, AED in Pakistan, Defibrillator in Pakistan and almost all type of Cardiology Equipment in Pakistan.Blood Pressure Apparatus M2
Blood Pressure Apparatus M2
Blood Pressure Apparatus M2 allows you comfortably, quickly and accurately check your blood pressure and monitor your results easily. Monitoring is made easy with the fully automatic digital OMRON M2 which features Intellisense Technology for soft cuff inflation. It is so easy to use you can take readings with just one touch. Features and cautions Intellisense Technology - this unique OMRON technology ensures that there is less discomfort from over-inflation of the cuff. Helps you take your blood pressure quickly and easily with one touch operation. Included cuff fits arms with a circumference of 22 - 32 cm. Specification:- Device Type: Upper Arm Blood Pressure Monitor
- Cuff Type: Medium Cuff 22-32cm
- Memory: 30 Readings
- Cuff Wrap Guide: Yes
- Blood Pressure Level Indicator: Yes
- Irregular Heart Beat Detection: Yes
- Storage Case Included: Yes
- Validation Type: Clinical Validation
- Intellisense Technology: Yes
- Stroke Prevention: Yes
- Length cm: 12.50
- Height cm: 16.50
- Depth cm: 12.00
- M2 blood pressure monitor
- Cuff
- Instruction Manual
- Blood Pressure Pass
- Batteries and Storage case
BP Aneroid Riester Germany
BP Aneroid Riester Germany
BP Aneroid Riester Germany isn't your average aneroid blood pressure monitor. Sure, it fits snugly in the palm of your hand, making it portable and convenient. But within that compact design lies a powerhouse of features that cater to both healthcare professionals and self-monitoring individuals.Patient Monitor Truscope ll Schiller
Patient Monitor Truscope ll Schiller
Patient Monitor Truscope ll Schiller is a Multi-ParaMeter Patient Monitor this Lightweight Modular Patient monitor is equipped with a 12.1" high resolution color TFT LCD display, Offering the parameters ECG, RESP, NIBP, TEMP and SPO2. please click on the link to download product brochure MULTI PARAMETER PATIENT MONITOR TRUSCOPE II.pdf For More information please call +92-322-4602203 or Email: zirarenterprises@gmail.com, info@zirarenterprises.com FEATURES:- 12.1" high resolution color TFT LCD display
- Critical parameters ECG, SpO2, NIBP, Temp, Resp monitored
- 12 lead ECG waveform display & total 11 waveforms display
- ST analysis, arrhythmia analysis
- Digital SpO2 even for low perfusion cases
- 72 hours tabular and graphical trends & data storage
- Drug dose calculation software
- OXYCRG software
- Certification: CE 0123, FDA
- Upgradable to 12 lead, dual IBP, thermal recorder, ETCO2, Multigas (CO2, O2, N2O and 5 Anaesthetic Agent) & second temperature (rectal)
- Nellcor technology for pulse oximetry
- Video Output (VGA)
- CNS: Wired / Wireless
- Upgradable to 12 lead, dual IBP, thermal recorder, ETCO2, Multigas (CO2, O2, N2O and 5 Anaesthetic Agent) & second temperature (rectal)
- Nellcor technology for pulse oximetry
- Video Output (VGA)
- CNS: Wired / Wireless