Cubix ECG/EKG Holter Machine MDX USA

Cubix ECG/EKG Holter Machine MDX USA

Cubix ECG/EKG Holter Machine MDX USA is a state-of-the-art holter device to measure patients EKG signals constantly throughout their day without being a discomfort due to its compact size. An event marker button allows a patient to mark the time when he or she feels cardiac distress allowing doctors to easily find data according to the event market time. The Cubix holter is a must have portable device for any cardiologist to do a complete and thorough diagnosis of patients. Please click to download the full catalog Cubix™ Holter ECG.pdf or visit the manufacturers website Cubix ECG/EKG Holter Machine MDX USA Recorder Features ■ With advanced design and technology, the recorder can work stably, dependable and is durable. ■ Be provided with the capability of anti-jamming and shock-pro. ■ Small volume with OLED screen. The resolution is 160*128. ■ Be provided with functions of waveform preview, record review and event marking. ■Accurate record of the start time of the data sampled owing to the real time clock of itself. ■Avoid damage owing to the repeating inserting and pulling out by using the inbuilt TF card to storage the data. ■The maximum capability can be 2GB, so the original data can be saved perfectly by no compression. ■The average review time of single case can be less than 40 seconds by using interface of USB 2.0. ■Record waveform details inextenso by the design of high precision and sampling frequency. ■Record the state of pacemaker exactly by higher sampling frequency. The features of software ■Quick and accurate analysis system. ■With 3 leads synchro analysis, QRS search can be more exactly. ■ There are more than 10 templates as atrial premature beat module, ventricular premature beat module, long interval module, atrial flutter module, atrial fibrillation module etc. and multiplicate User-defined templates could almost identify every kind of pathologic waveforms. ■Optional main channel. ■ Agile and exact "Atrial Fibrillation" analysis. ■The function of pacing analysis could analyse all pacemakers. ■ Many pacine modules have been added. ■ Any period of single lead or 3-leads ECG can be reviewed at any time with the  function of fast waveform review and analysis. ■ The types of the analysis system of HR variability include five minutes of short ECG and one hour or 24-hour of long ECG. ■ Print report expediently. ■ Perfect function of case management. ■ With the function of ST segment analysis and general load of the disorder of the heart muscle, the physician can judge a disease or disorder of the heart muscle generally. ■"Sleep breath pause syndrome analysis", the physician could print sleep asphyxia analysis report and diagnose. ■"HRT" analysis, when the adjustable function is natural, this transitory change  will be represented by the form of HRT immediately. ■15."T Wave Alternation" analysis is a important index on judging and preventing arrhythmia. Standards
  • Number of channels: 3 channels;
  • Sampling rate: 10000Hz;
  • Sampling accuracy:12bit;
  • Recording time : 24 h;
  • Power: 2 batteries in size 5;
  • Interface: USB2.0;
  • Scale voltage:1mV±5%;
  • Standard Sensitivity:10mm/mV±5%;
  • Noise level:≤30μV;
  • CMRR:≥60dB;
  • Feathers of low frequency : Time constant>3.2s;
  • Scan speed:25mm/s±5%;
  • Enduring polarization voltage:±300mV;
  • Least measure signal : 50 µV p-p;

Defibrillator Defi Xpress Meditech

Defibrillator Defi Xpress Meditech

Defibrillator Defi Xpress Meditech is defibrillator device with voice alarm which can meet your clinical needs from Basic Life Support (BLS) to Advanced Cardiac Life Support (ACLS). Defibrillators benefit patients who experience a sudden case of heartbeat is arrhythmias. In these instances Defibrillators are an important tool for anyone in the vicinity of a victim suffering from ventricular arrhythmia as well. arrhythmia renders the patient unconscious. the heart may beat too fast, too slow or an irregular mix of both. The anticipated outcome of sucharrhythmias is either cardiac arrest or a stroke.

Product Features:

Display Screen Type: High-resolution display Screen Size: 7 inches (17.7 cm) diagonally Sweep Speed: 25mm/sec Information: Heart Rate . Lead/Pads. Alarm . On/Off . SpO2 . AED Functions and Prompts Alarm Selection and Limits Delivered Energy. 5 Languages available: English.Russian.Spanesh.Chinese.Turkish Defibrillator Waveform: Biphasic Charge Time: Less than 7 seconds with a new fully charged battery. Energy Display: Monitor display indicates both selected and delivered energy. Charge Prompt Type: Voice and visual prompts. Electrode Impedance Measurement Range: 0-250 ohms. ECG Monitoring Patient Connection: 3-lead ECG cable or 5-lead ECG cable paddles. Lead Selection: Displayed on monitor paddles I II III AVR AVL AVF V. ECG Size: 0.25 0.5 1 1.5 2 4 cm/mV display on monitor. Heart Rate: 20-300BPM. Heart Rate Alarm: On/Off displayed on monitor user-selectable. Smart Alarms: Beeper/voice prompts indicate shock able rhythm. Battery Type: Rechargeable Ni-MH battery 12V. Operating time: For a new fully charged battery: 60 defibrillator discharges at maximum energy or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions. SpO2 Module (Options): Measurement Range: 30~100% ±2% between 80%~90% others ±5% Alarm Range: User set high limit and low limit. Alarm Accuracy: ±10% within setting values. Alarm time Accuracy: less than 12 sec. 1-Meditech Pulse Oximeter 2-Nellcor Pulse Oximeter Recorder Paper: 50mm thermal. Speed: 12.5mm/sec 25mm/sec 50mm/sec. User-selectable 6-second delay. Printing Method: High-resolution thermal print head. Print-out Modes: Manual or automatic user-configurable. On/Off Control: Front panel and paddle. Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge. AED Mode AED Function: Auto analyze and charge x3 with programmable auto energy level selection screen prompts and voice prompts. Shockable Rhythms: Ventricular fibrillation with amplitude >=200uV ventricular tachycardia with rates >=140bpm and QRS complex wave duration >=140ms. Charge Control: Control on device front panel press key on paddle. Prompts: Voice and visual prompts. Manual Mode Energy Selection: Selectable at 2 5 7 10 20 30 50 70 100 150 200 300 360 joules. Synchronized Mode: Synchronizes defibrillator pulse to patient's R-wave. "SYNC" message displayed on monitor.

Technical Specification:

The Specification of physical electronic isolation defibrillator battery electromagnetic compatibility and rhythm recognition performance will be described in this section: Data Acquisition and Analysis The DEFI XPRESS is no longer automatically configured to a certain frequency response. There are two diagnostic frequency options: 0.05-150 Hz Diagnostic Frequency Filter and 0.05-40 Hz Filtered Diagnostic Frequency filter. See chapters 7 on switching between these two options. Defibrillator Waveform Details: The tables below provide details of the waveforms delivered by the DEFI XPRESS when connected to resistive loads of 25 50 and 100 Ohms and set to its maximum output. The waveforms are characterized by DEFI XPRESS values ​​for peak current (Ip) for biphasic: duration of The first output phase (tphase1) and duration of the second output phase (tphase2). The values ​​shown are within 10%. Waveform: Truncated Exponential Biphasic Output Energy Accuracy: +/- 10% or 1J (whichever is greater) at 50 ohms +/- 15% or 1J (whichever is greater) at 25 to 100 ohms Energy Select: External: 2 5 7 10 20 30 50 70 100 150 200 300 360 J. Charge Time: < 12 seconds @ 360 J (with a Ni-MH 12 volt - MEDITECH battery after15discharges). < 15 seconds @ 360 J (no battery 90% AC mains voltage) Charge Indicator: Audible and graphic. Output : Adult paddles pediatric adapter and multipurpose hands-free adapter available. Synchronizer: Delivers energy within 60 msec. Disarm: Front panel switch. Monitor/Display Input: 3-lead 5-lead patient cable Size: 7 inches (16.5 cm) diagonal non-fade. Type: color (TFT) Display Resolution: 800 x 600 pixels. Sweep Speed: 12.5mm/s25mm/s50mm/s Lead Selections: I II III AVR AVL AVF V. Frequency Response: (User-selectable). 0.7 to 20 Hz operation mode 0.3 to 40 Hz Monitoring mode 0.05 to 150 Hz Analysis mode 0.5 to 30 Hz AED mode Common Mode Rejection:>=60dB Heart Rate Meter: 20 to 300 BPM. Heart Rate Alarms: User-selectable. Size: 0.125 0.25 0.5 1 2 4 cm/mv and auto-ranging. ECG Output: 1 V/mV. Heart Rate Response to Irregular Rhythm: (AAMI EC13-1992 section 4.1.2.1.e.) Alarms Heart Rate Spo2 Alarm: Audible: 5 pulse 800 tone with a PW of 150 msec a PRI of 225 msec and a repetition interval of 10 seconds. Visual: Heart Rate Alarm causes the displayed heart rate to flash at 2 Hz. This display is located at the top of the display and is 0.4" high and 0.28 to 0.840" wide depending on num-ber of digits in the heart rate. Is amber black white or whatever the color the display text is. Lead Fault Alarm: Audible: 3 pulse 500 Hz triplet tone with a PW of 200 msec a PRI of 310 msec. When the HR alarm is set or the pacer is on the lead fault tone repeats at a repetition interval of 20 seconds. Visual: Lead Fault condition causes a "LEAD FAULT" message to be displayed on the trace along with a dashed line the width of the trace. The text is 0.18" high and is the color of the display text. The dashed line is 5" Long the width of the display. The signal is not modulated. Physiological Alarms (Spo2): Audible: See Heart Rate Alarm Visual: Physiological alarms cause the displayed parameter to flash at 2 Hz. Color is amber white or the same as the display colored text. Mute Duration: 90 seconds. Recorder Type: High-resolution thermal array. Annotation: Time date ECG lead ECG gain heart rate defibrillation and treatment summary ACLS events. Paper Width: 50 mm. Paper Speed: 25 mm/sec 50 mm/sec 12 Lead 50 mm/sec Delay: 6 seconds. Frequency Response: Automatically set to monitor's frequency response. Battery High Capacity Type: Ni-MH 12V volt - MEDITECH Up to 4 hours ECG monitoring or 110 full-energy dis-charges or 3 hours combined ECG Spo2 and monitor-ing Proper battery care is required to maintain maximum avail-able capacity. Low Battery Indicator: Flashing low battery icon on display and flashing LED on front panel.. Recharge Rate: 80% in 7.5 hours. 100% in 9 hours. General Weight: 10 pounds (4.95 kg) (basic configuration). Size: 13 x 12.5 x 5.3 inches (33 x 31.8 x 13.5 cm). Operating: Temperature*: 0 to 45° C Humidity* (NC): 15 to 95% RH (30 to 90% with CO2 probe) Vibration*: MIL-STD 810E Shock / Drop*: MIL-STD 810E Altitude: Up to 4572 M (15000 feet) Transport and Storage: Temperature: -30 to 70°C (-20 to 70°C with CO2 probe) Humidity: 15 to 95% RH (non-condensing) Atmospheric pressure: 860 to 1060 hPa Shock/vibration: ISTA 1A Enclosure Protection*: Solid Foreign object: IEC 529 IP2X Water: IEC 529 IPX4. All tests performed per AAMI DF-2 Defibrillation Standard. Operating Power: Ni-MH 12 volt - MEDITECH SAED Rhythm Recognition Performance The DEFI XPRESS SAED algorithm exceeds the requirements of ANSI/AAMI