12 Channel Portable ECG Recorder Meditech
12 Channel Portable ECG Recorder Meditech
12 Channel Portable ECG Recorder Meditech, Model: HeartRec Eco, Meditech contains recorder & analysis software. Recorder is an easy- to -use unit, which collects 12-lead ECG waveform synchronously and records continuously for 48 hours. With the clear operating interface, analysis software is easy for you to use, which can play back and classifying dispose ECG waveform stored in recorder and achieve kinds of analysis functions, such as arrhythmia, HRV, QTD, TWA
For more information, questions, queries, quotations and prices please feel free to contact us +92-322-4602203 or Email: info@zirarenterprises.com, zirarenterprises@gmail.com
Product Features:
ECG Holter Compact design and small size with OLED display with 12 leads synchro analysis QRS search can be more exactly
There are more than 10 templates as atrial premature beat module ventricular premature beat module:
Long interval module
Atrial flutter module
Atrial fibrillation module etc.and multiplicative User-defined templates could almost identify every kind of pathological wave forms Flexible atrial fibrillation analysis so that physicians can use full segmented automatic manual analysis of atrial fibrillation make the analysis more quickly and accurately.
Powerful pacemaker analysis on the AAI VVI DDD etc. all pacemaker analysis
Analysis of heart rate variability with short-range 5 minutes and long-range 1 hour and full analysis of heart rate variability
Analysis can predict the risk of death in patients with myocardial infarction “Heart rate turbulence”
Analysis is a important index on judging and preventing Arrhythmia “T Wave alternation”
The report has more reference value with the functions of VCG VLP TVCG and QTD analysis.
Recorder features:
Removable TF card(volume: up to 2GB).
Work on “AAA” size battery and workable for 60 hours.
Separated electrodes synchronously collect the 12-lead ECG data (easy for replacement).
Technical Specification:
- Scale voltage: 1mV±5%
- Standard Sensitivity: 10mm/mV±5%
- Noise level: ≤30μV p-p
- CMRR: ≥60dB
- Frequency response: 10Hz as benchmark 0.5Hz~55Hz;-3dB
- Time constant: Time constant≥3.2s
- Scan speed: 25mm/s±5%
- Enduring polarization voltage: add ±300mV DC polarization voltage the sensitivity shift is no more than ± 10%Least measure
- signal: 50 μV p-p
- Interfere between channels: scan track deflexion (result from interfere between channels) ≤0.5mm
- 12-lead isochronous ECG sample
- Product safety type: Type B (Internally powered)
- Size: 80.5mm (L) *59.5mm (W) *22mm (H)
- Net Weight: 61.5g (Without battery)
Environment Condition and Applicable People
The environment requirement of operation transport and storage for this System.
Operation Environment
Environment Temperature: 10℃~45℃
- Relative Humidity: ≤85% no condensation.
- Atmospheric pressure : 860hPa-1060hPa
- Power Supply: DC 1.5V
- 1Application Environment:
- No vibration dust corrosive or combustible matter.
- No extreme temperature and humidity.
- Transport and Storage Environment
- Environment Temperature: -40℃~+55℃
- Relative Humidity: ≤85%
- Atmospheric pressure: 860hPa-1060hPa
- Computer Configuration and Printer Requirement for Software
- CPU: Pentium III Celeron(CYON)800 or advanced
- EMS memory: 256M or above
- Hard disk: 40G or above
- CD-ROM: CD-ROM or advanced
- I/O port: More than four USB2.0 ports
- Operating System: Microsoft Windows 2000(32bit)/XP(32bit)/Vista(32bit)/Windows 7(32bit)
- Microsoft Windows 2000(64bit)/XP(64bit)/Vista(64bit)/Windows 7(64bit)
- Display: Color display with the resolution1024×768 or advanced
Requirement
Resolution of printer: 600DPI
12 Channel Portable ECG Recorder Meditech
12 Channel Portable ECG Recorder Meditech, Model: HeartRec Eco, Meditech contains recorder & analysis software. Recorder is an easy- to -use unit, which collects 12-lead ECG waveform synchronously and records continuously for 48 hours. With the clear operating interface, analysis software is easy for you to use, which can play back and classifying dispose ECG waveform stored in recorder and achieve kinds of analysis functions, such as arrhythmia, HRV, QTD, TWA
For more information, questions, queries, quotations and prices please feel free to contact us +92-322-4602203 or Email: info@zirarenterprises.com, zirarenterprises@gmail.com
Product Features:
ECG Holter Compact design and small size with OLED display with 12 leads synchro analysis QRS search can be more exactly
There are more than 10 templates as atrial premature beat module ventricular premature beat module:
Long interval module
Atrial flutter module
Atrial fibrillation module etc.and multiplicative User-defined templates could almost identify every kind of pathological wave forms Flexible atrial fibrillation analysis so that physicians can use full segmented automatic manual analysis of atrial fibrillation make the analysis more quickly and accurately.
Powerful pacemaker analysis on the AAI VVI DDD etc. all pacemaker analysis
Analysis of heart rate variability with short-range 5 minutes and long-range 1 hour and full analysis of heart rate variability
Analysis can predict the risk of death in patients with myocardial infarction “Heart rate turbulence”
Analysis is a important index on judging and preventing Arrhythmia “T Wave alternation”
The report has more reference value with the functions of VCG VLP TVCG and QTD analysis.
Recorder features:
Removable TF card(volume: up to 2GB).
Work on “AAA” size battery and workable for 60 hours.
Separated electrodes synchronously collect the 12-lead ECG data (easy for replacement).
Technical Specification:
- Scale voltage: 1mV±5%
- Standard Sensitivity: 10mm/mV±5%
- Noise level: ≤30μV p-p
- CMRR: ≥60dB
- Frequency response: 10Hz as benchmark 0.5Hz~55Hz;-3dB
- Time constant: Time constant≥3.2s
- Scan speed: 25mm/s±5%
- Enduring polarization voltage: add ±300mV DC polarization voltage the sensitivity shift is no more than ± 10%Least measure
- signal: 50 μV p-p
- Interfere between channels: scan track deflexion (result from interfere between channels) ≤0.5mm
- 12-lead isochronous ECG sample
- Product safety type: Type B (Internally powered)
- Size: 80.5mm (L) *59.5mm (W) *22mm (H)
- Net Weight: 61.5g (Without battery)
Environment Condition and Applicable People
The environment requirement of operation transport and storage for this System.
Operation Environment
Environment Temperature: 10℃~45℃
- Relative Humidity: ≤85% no condensation.
- Atmospheric pressure : 860hPa-1060hPa
- Power Supply: DC 1.5V
- 1Application Environment:
- No vibration dust corrosive or combustible matter.
- No extreme temperature and humidity.
- Transport and Storage Environment
- Environment Temperature: -40℃~+55℃
- Relative Humidity: ≤85%
- Atmospheric pressure: 860hPa-1060hPa
- Computer Configuration and Printer Requirement for Software
- CPU: Pentium III Celeron(CYON)800 or advanced
- EMS memory: 256M or above
- Hard disk: 40G or above
- CD-ROM: CD-ROM or advanced
- I/O port: More than four USB2.0 ports
- Operating System: Microsoft Windows 2000(32bit)/XP(32bit)/Vista(32bit)/Windows 7(32bit)
- Microsoft Windows 2000(64bit)/XP(64bit)/Vista(64bit)/Windows 7(64bit)
- Display: Color display with the resolution1024×768 or advanced
Requirement
Resolution of printer: 600DPI
You must be logged in to post a review.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
12 Channel ECG Cardio7 Bionet
12 Channel ECG Cardio7 Bionet
12 Channel ECG Cardio7 Bionet device is classified as follows, in accordance with IEC60601-1. There are a lot of ECG Machines in the market but the reputation of Bionet is absolutely phenomenal, please bear in mind that Bionet is USA Based company but the products are manufactured in Korea. However each and every single product is FDA Approved. 12 Channel ECG Cardio7 Bionet device or system is suitable for use in all establishments other than domestic and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. Mains power should be a typical commercial or hospital environment. For more information regarding the product please feel free to contact us.CLICK HERE TO DOWNLOAD THE CATALOG Bionet Cardio7_ECG.pdf
Features:
12 channel interpretive ECG for adult, pediatric and neonatal use over 130 kinds of interpretation results based on advanced Minnesota code, HRV (Hearth Rate Variability analysis)- memory for up to 200 patients
- real-time preview monitor
- PC compatible through LAN or Wi-Fi
- multi-Ianguage selectable software (GB, RU, FR, DE, IT, CN, ES, TU, PL, RU, PT)
- lead fault message
- pace maker detection
- automatic arrhythmia detection
- 3, 5, 10 minutes long term recording
- grid function allows you to use low cost plain fax paper
- wide and clear colour 7” TFT LCD (800x480)
- touch screen for easy operation
- full disclosure function
Specification:
ECG leads: 10 lead, 12 channel simultaneous ECG and acquisition • Dimension: 300(W) x 299(H) x 123(D)mm, approx. 3.5 kg • Recording channel: 3 channels + 1 rhythm, 3 channels + 3 rhythm, 6 channels + 1 rhythm, 12 channels, 60 seconds 1 channel, 3, 5, 10 minutes 1 channel and beat report • Sensitivity: 2.5, 5, 10, 20, auto (l~aVF: 10, V1~V6: 5) mm/mV • Printing speed: 5, 12.5, 25, 50, 100 mm/s • Sampling rate: 2,000 samples/sec • Filters: AC (50/60 Hz, -20 dB or better) • Muscle (25~35 Hz, -3dB or better) • Base line drift (0.05, 0.1, 0.2 Hz, -3dB or better) • Low pass filter: off, 40 Hz, 100 Hz, 150 Hz • Display: 7" color TFT LCD display (800x480), 12 channels preview ECG wave • Monitor display: ID, date, sensitivity, speed, filter, form, rhythm lead • User interface: Touch screen (alphanumeric and symbol available), Keyboard, rotary push-knob (pop-up menu) • Patient data: ID, name, age, sex, height, weight, smoke, race • Basic measurement: Heart rate, PR int, QRS dur, QT/QTc, P-R-T axis • Recorder: Thermal print head, roll paper, A4 report paper: 210x300 mm (8.5"x11") • Resolution: - Vertical: 8 dot/mm - Horizontal: 16 dot/mm • Electrical: - Internal noise: 20 µV (p-p) max - Input circuit: floating input - Input impedance: =50 MO - Input voltage range: = ±5 mV - Common mode rejection: > 105 dB - DC offset voltage: = ±400 mV - Time constant: 3.2 sec - Patient leakage current: < 10 µA - Frequency response: 0.05 ~150 Hz - Isolated and defibrillation protected • Signal quality control: Disconnected lead detection, Pacemaker pulse detection • ECG data storage: storage for 200 ECGs (Internal on flash memory) • Power: 100~240 VAC, 50/60 Hz or battery (option) 2.0~1.0 A, 60 VA max • Battery (Li-Ion): 4 hours of normal use (approx.200 ECG printouts) • Communication: PC connection with LAN D2 Wi-Fi • Safety conformity: Class I, Type CF, CE, CSA, FDA, KFDA, CFDA, CCC General Information of 12 Channel ECG Cardio7 Bionet For more information regarding ecg machine price in Pakistan, 3 channel ecg machine price in Pakistan or 12 channel ecg price in Pakistan please feel free to contact us. Our technical staff will provide you full back-up and support in all over Pakistan. When talk about ecg price in Pakistan or ecg machine price in Pakistan we are the number one company in entire Pakistan to provide ECG Machines in Pakistan, ETT Machines in Pakistan, Patient Monitors in Pakistan, Cardiac Monitors in Pakistan, AED in Pakistan, Defibrillator in Pakistan and almost all type of Cardiology Equipment in Pakistan.Autoclave Double Drum 30 LBS Pakistan
Autoclave Double Drum 30 LBS Pakistan
Autoclave Double Drum 30 LBS Pakistan is a best featured and manufactured product by Zirar Enterprises, We are one of the top leading manufacturer and distributor of autoclaves in Pakistan. We are manufacturing top-notch sterilizers and autoclaves in Pakistan. As we are the manufacturer of autoclaves so we can build or modify autoclaves according to your needs. Why Autoclave? or Autoclave Double Drum 30 LBS Pakistan Autoclave provides a physical method for sterilization in order to kill bacteria, microorganisms and spores. They are used to decontaminate certain biological waste and sterilize media, instruments and lab ware also it is highly recommended to sterilize medical instrument before disposing it off. Autoclave Double Drum 30 LBS Pakistan and Accessories Zirar Enterprises not only stops at autoclaves but we are also providing wide range of accessories to use before handling autoclaves for e.g. (Lab Coats, Safety Goggles, Safety Gloves and Shoes). Types of Autoclaves for Sale in Pakistan- Horizontal Autoclaves & sterilizers
- Vertical Autoclaves & sterilizers
- Electrical and Gas Autoclaves
- Fully SS (stainless steel autoclaves)
- MS & SS autoclaves
- Capacity: Auto clave 100L (16x30) Horizontal
- Drum: Double chamber (Jacket & Chamber)
- Material: MS Mild steel and SS Stainless steel (SS sheet size 2.5 MM for double chamber and 1.5 for single chamber)
- Working pressure: 30 – 35 pound (can be used up to 50-pound pressure if needed)
- Power: Electric 3 phase + Gas
- Wika Gauges: Water pressure gauge, steam pressure gauge and chamber pressure gauge.
- Valves: Safety valves & emergency steam release valves.
Automated Hematology Analyzer DC 2400 Plus
Automated Hematology Analyzer DC 2400 Plus
Automated Hematology Analyzer DC 2400 Plus is one of the best Fully automated hematology analyzer which can perform two duties at the same time monitoring of the blood cells having diseased cells and at the same time counting them. DiA CELL DC-2400 PLUS is very useful machine for the patients, laboratory staff etc, some of the features are: Features:- Perfect QA
- Simple to Operate
- Convenient Maintenance
- Advanced Design
Carry Over: RBC, WBC, HGB <0.5%, PLT<1.0%
Operating Interface: Colorful Windows interface, no need connecting computer. Operating by graphic button with mouse and keyboard
Display: Big size 10.4’’ TFT LCD, all parameters and histograms displayed in the same screen
Print Mode: Internal high-speed thermal printer. Optional connection with specified external printer. English printouts
Reagents System: Open reagent system. No cyanogen reagents. Provide original reagents.
Connection Port: USB, RS-232, network interface
Power: Maximum 150VA
Environment: Temperature 10℃-35℃. Relative humidity: 10%-90%
Power Supply: 220(1±10%)V, (50±1)Hz. 90V-260V, 50-60Hz broad range power available for different Countries
Dimension: 520mm×460mm×420mm
Weight: 23Kg

Reviews
There are no reviews yet.