Cubix ECG/EKG Holter Machine MDX USA
Cubix ECG/EKG Holter Machine MDX USA
Cubix ECG/EKG Holter Machine MDX USA is a state-of-the-art holter device to measure patients EKG signals constantly throughout their day without being a discomfort due to its compact size. An event marker button allows a patient to mark the time when he or she feels cardiac distress allowing doctors to easily find data according to the event market time.
The Cubix holter is a must have portable device for any cardiologist to do a complete and thorough diagnosis of patients. Please click to download the full catalog Cubix™ Holter ECG.pdf or visit the manufacturers website
Cubix ECG/EKG Holter Machine MDX USA
Recorder Features
■ With advanced design and technology, the recorder can work stably, dependable and is durable.
■ Be provided with the capability of anti-jamming and shock-pro.
■ Small volume with OLED screen. The resolution is 160*128.
■ Be provided with functions of waveform preview, record review and event marking.
■Accurate record of the start time of the data sampled owing to the real time clock of itself.
■Avoid damage owing to the repeating inserting and pulling out by using the inbuilt TF card to storage the data.
■The maximum capability can be 2GB, so the original data can be saved perfectly by no compression.
■The average review time of single case can be less than 40 seconds by using interface of USB 2.0.
■Record waveform details inextenso by the design of high precision and sampling frequency.
■Record the state of pacemaker exactly by higher sampling frequency.
The features of software
■Quick and accurate analysis system.
■With 3 leads synchro analysis, QRS search can be more exactly.
■ There are more than 10 templates as atrial premature beat module, ventricular premature beat module, long interval module, atrial flutter module, atrial fibrillation module etc. and multiplicate User-defined templates could almost identify every kind of pathologic waveforms.
■Optional main channel.
■ Agile and exact “Atrial Fibrillation” analysis.
■The function of pacing analysis could analyse all pacemakers.
■ Many pacine modules have been added.
■ Any period of single lead or 3-leads ECG can be reviewed at any time with the function of fast waveform review and analysis.
■ The types of the analysis system of HR variability include five minutes of short ECG and one hour or 24-hour of long ECG.
■ Print report expediently.
■ Perfect function of case management.
■ With the function of ST segment analysis and general load of the disorder of the heart muscle, the physician can judge a disease or disorder of the heart muscle generally.
■”Sleep breath pause syndrome analysis”, the physician could print sleep asphyxia analysis report and diagnose.
■”HRT” analysis, when the adjustable function is natural, this transitory change will be represented by the form of HRT immediately.
■15.”T Wave Alternation” analysis is a important index on judging and preventing arrhythmia.
Standards
- Number of channels: 3 channels;
- Sampling rate: 10000Hz;
- Sampling accuracy:12bit;
- Recording time : 24 h;
- Power: 2 batteries in size 5;
- Interface: USB2.0;
- Scale voltage:1mV±5%;
- Standard Sensitivity:10mm/mV±5%;
- Noise level:≤30μV;
- CMRR:≥60dB;
- Feathers of low frequency : Time constant>3.2s;
- Scan speed:25mm/s±5%;
- Enduring polarization voltage:±300mV;
- Least measure signal : 50 µV p-p;
Cubix ECG/EKG Holter Machine MDX USA
Cubix ECG/EKG Holter Machine MDX USA is a state-of-the-art holter device to measure patients EKG signals constantly throughout their day without being a discomfort due to its compact size. An event marker button allows a patient to mark the time when he or she feels cardiac distress allowing doctors to easily find data according to the event market time.
The Cubix holter is a must have portable device for any cardiologist to do a complete and thorough diagnosis of patients. Please click to download the full catalog Cubix™ Holter ECG.pdf or visit the manufacturers website
Cubix ECG/EKG Holter Machine MDX USA
Recorder Features
■ With advanced design and technology, the recorder can work stably, dependable and is durable.
■ Be provided with the capability of anti-jamming and shock-pro.
■ Small volume with OLED screen. The resolution is 160*128.
■ Be provided with functions of waveform preview, record review and event marking.
■Accurate record of the start time of the data sampled owing to the real time clock of itself.
■Avoid damage owing to the repeating inserting and pulling out by using the inbuilt TF card to storage the data.
■The maximum capability can be 2GB, so the original data can be saved perfectly by no compression.
■The average review time of single case can be less than 40 seconds by using interface of USB 2.0.
■Record waveform details inextenso by the design of high precision and sampling frequency.
■Record the state of pacemaker exactly by higher sampling frequency.
The features of software
■Quick and accurate analysis system.
■With 3 leads synchro analysis, QRS search can be more exactly.
■ There are more than 10 templates as atrial premature beat module, ventricular premature beat module, long interval module, atrial flutter module, atrial fibrillation module etc. and multiplicate User-defined templates could almost identify every kind of pathologic waveforms.
■Optional main channel.
■ Agile and exact “Atrial Fibrillation” analysis.
■The function of pacing analysis could analyse all pacemakers.
■ Many pacine modules have been added.
■ Any period of single lead or 3-leads ECG can be reviewed at any time with the function of fast waveform review and analysis.
■ The types of the analysis system of HR variability include five minutes of short ECG and one hour or 24-hour of long ECG.
■ Print report expediently.
■ Perfect function of case management.
■ With the function of ST segment analysis and general load of the disorder of the heart muscle, the physician can judge a disease or disorder of the heart muscle generally.
■”Sleep breath pause syndrome analysis”, the physician could print sleep asphyxia analysis report and diagnose.
■”HRT” analysis, when the adjustable function is natural, this transitory change will be represented by the form of HRT immediately.
■15.”T Wave Alternation” analysis is a important index on judging and preventing arrhythmia.
Standards
- Number of channels: 3 channels;
- Sampling rate: 10000Hz;
- Sampling accuracy:12bit;
- Recording time : 24 h;
- Power: 2 batteries in size 5;
- Interface: USB2.0;
- Scale voltage:1mV±5%;
- Standard Sensitivity:10mm/mV±5%;
- Noise level:≤30μV;
- CMRR:≥60dB;
- Feathers of low frequency : Time constant>3.2s;
- Scan speed:25mm/s±5%;
- Enduring polarization voltage:±300mV;
- Least measure signal : 50 µV p-p;
You must be logged in to post a review.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
12 Channel ECG Cardio7 Bionet
12 Channel ECG Cardio7 Bionet
12 Channel ECG Cardio7 Bionet device is classified as follows, in accordance with IEC60601-1. There are a lot of ECG Machines in the market but the reputation of Bionet is absolutely phenomenal, please bear in mind that Bionet is USA Based company but the products are manufactured in Korea. However each and every single product is FDA Approved. 12 Channel ECG Cardio7 Bionet device or system is suitable for use in all establishments other than domestic and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. Mains power should be a typical commercial or hospital environment. For more information regarding the product please feel free to contact us.CLICK HERE TO DOWNLOAD THE CATALOG Bionet Cardio7_ECG.pdf
Features:
12 channel interpretive ECG for adult, pediatric and neonatal use over 130 kinds of interpretation results based on advanced Minnesota code, HRV (Hearth Rate Variability analysis)- memory for up to 200 patients
- real-time preview monitor
- PC compatible through LAN or Wi-Fi
- multi-Ianguage selectable software (GB, RU, FR, DE, IT, CN, ES, TU, PL, RU, PT)
- lead fault message
- pace maker detection
- automatic arrhythmia detection
- 3, 5, 10 minutes long term recording
- grid function allows you to use low cost plain fax paper
- wide and clear colour 7” TFT LCD (800x480)
- touch screen for easy operation
- full disclosure function
Specification:
ECG leads: 10 lead, 12 channel simultaneous ECG and acquisition • Dimension: 300(W) x 299(H) x 123(D)mm, approx. 3.5 kg • Recording channel: 3 channels + 1 rhythm, 3 channels + 3 rhythm, 6 channels + 1 rhythm, 12 channels, 60 seconds 1 channel, 3, 5, 10 minutes 1 channel and beat report • Sensitivity: 2.5, 5, 10, 20, auto (l~aVF: 10, V1~V6: 5) mm/mV • Printing speed: 5, 12.5, 25, 50, 100 mm/s • Sampling rate: 2,000 samples/sec • Filters: AC (50/60 Hz, -20 dB or better) • Muscle (25~35 Hz, -3dB or better) • Base line drift (0.05, 0.1, 0.2 Hz, -3dB or better) • Low pass filter: off, 40 Hz, 100 Hz, 150 Hz • Display: 7" color TFT LCD display (800x480), 12 channels preview ECG wave • Monitor display: ID, date, sensitivity, speed, filter, form, rhythm lead • User interface: Touch screen (alphanumeric and symbol available), Keyboard, rotary push-knob (pop-up menu) • Patient data: ID, name, age, sex, height, weight, smoke, race • Basic measurement: Heart rate, PR int, QRS dur, QT/QTc, P-R-T axis • Recorder: Thermal print head, roll paper, A4 report paper: 210x300 mm (8.5"x11") • Resolution: - Vertical: 8 dot/mm - Horizontal: 16 dot/mm • Electrical: - Internal noise: 20 µV (p-p) max - Input circuit: floating input - Input impedance: =50 MO - Input voltage range: = ±5 mV - Common mode rejection: > 105 dB - DC offset voltage: = ±400 mV - Time constant: 3.2 sec - Patient leakage current: < 10 µA - Frequency response: 0.05 ~150 Hz - Isolated and defibrillation protected • Signal quality control: Disconnected lead detection, Pacemaker pulse detection • ECG data storage: storage for 200 ECGs (Internal on flash memory) • Power: 100~240 VAC, 50/60 Hz or battery (option) 2.0~1.0 A, 60 VA max • Battery (Li-Ion): 4 hours of normal use (approx.200 ECG printouts) • Communication: PC connection with LAN D2 Wi-Fi • Safety conformity: Class I, Type CF, CE, CSA, FDA, KFDA, CFDA, CCC General Information of 12 Channel ECG Cardio7 Bionet For more information regarding ecg machine price in Pakistan, 3 channel ecg machine price in Pakistan or 12 channel ecg price in Pakistan please feel free to contact us. Our technical staff will provide you full back-up and support in all over Pakistan. When talk about ecg price in Pakistan or ecg machine price in Pakistan we are the number one company in entire Pakistan to provide ECG Machines in Pakistan, ETT Machines in Pakistan, Patient Monitors in Pakistan, Cardiac Monitors in Pakistan, AED in Pakistan, Defibrillator in Pakistan and almost all type of Cardiology Equipment in Pakistan.BP Aneroid Riester Germany
BP Aneroid Riester Germany
BP Aneroid Riester Germany isn't your average aneroid blood pressure monitor. Sure, it fits snugly in the palm of your hand, making it portable and convenient. But within that compact design lies a powerhouse of features that cater to both healthcare professionals and self-monitoring individuals.Micro Centrifuge Tube 2.0ml
Micro Centrifuge Tube 2.0ml
Micro Centrifuge Tube 2.0ml is one of the best and reliable centrifuge tubes made by Biomed Pakistan. The best thing about the centrifuge tubes are that they are autclaved and packed in different capacities as per the discretion of end-user. Micro Centrifuge Tube 2.0ml gives the best result and quality is 100% guaranteed. For more information regarding Micro Centrifuge Tube 2.0ml in Pakistan please feel free to contact us. Features:- Polypropylene clear polymer facilitates visualization of samples
- Attached snap caps
- Rated to 20,000 x G
- Graduations at every 100 μL for easy volume estimation
- Frosted writing sections in tube surface and tube cover for easy sample identification.
- Temperature range: -80°C to +121°C (Autoclave able)
- Certified free of detectable RNase, DNase & Pyrogen
- Affinity purification or affinity chromatography
- Immunodepletion
- Immunoprecipitation (IP)
- Mechanical failure of the machine
- Lab equipment failure (tubes, etc.)
- Aerosol generation
- Operator Error
- Operating Procedures
- Develop and implement a strict cleaning, storing, and maintenance protocol.
- Only use manufacturer compatible centrifuge, rotor, buckets, caps, and adapters.
- Replace centrifuge parts including bottles, tubes, and O-rings at the first sign of damage.
- Assemble the bottles, buckets, and rotor per the manufacturer’s instructions.
- Tightly seal all tubes and safety cups.
- Close lid during operation.
- Allow to come to complete stop before opening.
- Guideline for Safe Operation
- Use safety cups whenever possible.
- Disinfect or clean weekly and after all spills or breakages.
- Lubricate O-rings and rotor threads weekly.
- Do not operate the centrifuge without the rotor properly balanced.
- Do not use rotors that have been dropped.
- Inspect the speed disk for sign of damage if using an ultra-speed unit and
- discontinue use if damaged. Inspect the rotor and tube cavities for signs of damage and discontinue use if damaged.
- Contact your centrifuge representative for specific information.
- Micro Centrifuge Tube 2.0ml available in Pakistan in 1.0ml, 1.5ml, 2ml
Microplate Reader Rayto RT-6100
Microplate Reader Rayto RT-6100
Microplate Reader Rayto RT-6100 is one the best Microplate Reader in Pakistan, RT-6100 has one of the best quality Elisa Microplates reading. When we talk about the detection of Biological and Chemical data there are a lot of Equipment available in Pakistan and worldwide to get them detected through ELisa's, Enzyme Activities, Nuleic and Protein Quantification. When we talk about the Microplate Reader price in Pakistan, Microplate Reader Rayto RT-6100 is the ultimate choice of Lab Technicians. For more information, questions and queries please feel free to contact us. Features:- PC Controlled System
- 8 Channel optical fiber system enables 5 sec reading for 96 wells plate.
- Calculation Modes includes ABS, Cut-off, Curve, Linear, Log, Exponent, Power and 4PL Regressions.
- Upto 12 different tests can be performed in a single plate.
- Power Laboratory Management Software to store more than 100 Programs, 100,000 results.
- Powerful QC programs including Westguard Rules and instant method, automatic alarm,
- Multiform test reports output.
- Lamp saving and plate shaking feature.
- Save data automatically when power off unexpectedly.
- Compatible with all external printers supported in Windows.
- Powerful Internet Connection enables remote data sharing and OS update.
- Standard Language is English, Multiple Language Software is available on request.

Reviews
There are no reviews yet.