Liquid Nitrogen Generator Maxigas
₨ 3,000,000 Original price was: ₨ 3,000,000.₨ 2,000,000Current price is: ₨ 2,000,000.
Liquid Nitrogen Generator Maxigas
Liquid Nitrogen Generator Maxigas from Parker produce nitrogen gas from compressed air and offer a cost-effective, reliable and safe alternative to traditional nitrogen gas supplies such as cylinder or liquid. Nitrogen is used as a clean, dry, inert gas primarily for removing oxygen from products and/or processes.
MAXIGAS provides an on-demand, continuous source of nitrogen gas which can be used in a wide range of industries such as food, beverage, pharmaceutical, laboratory, chemical, heat treatment, electronics, transportation, oil and gas and laser cutting.
Click here to download full catalog MAXIGAS_Cat_174004704.pdf
The price includes complete unit and Installation at users desired location all across Pakistan.
Features:
• Can operate from a standard factory compressed air supply
• Delivers 5% down to 10 ppm oxygen content, without the need for any additional purification
• Available in 7 models offering varying flow rates and purities.
• Automatic economy mode
• Built-in oxygen analyzer for continuous purity monitoring
• Digital and analogue outputs for remote monitoring
• Alarm capabilities
• User friendly control interface
• Compact design
• Modular concept
Benefits:
Up to 90% cost savings*
Typical capital pay-back is achievable within 12-24 months.
Energy savings
Low air consumption provides greater energy efficiency.
Convenient and safe
The easy to use system is simple to install, requires minimal maintenance and eliminates safety hazards associated with
traditional gas supplies.
Space saving design
The compact design means the system demands less floor space.
Flexible multi-bank option
The modular concept means the generators can be mutli-banked if required.
Reduce carbon footprint
The elimination of cylinder deliveries and transportation means carbon footprint can be reduced.
Cost-effective, energy saving solution
In addition to a short pay-back period, the cost-effective solution removes costs associated with traditional gas supplies including refills, order processing, tank rental and delivery charges and eliminates future gas company price increases. While operating from a standard compressed air supply, the economy mode and on-demand function respectively offers control over nitrogen production, flow rates and purity levels and therefore limits costly wasted gas or liquid boil off to
facilitate excellent energy savings. The 24/7 operation also removes the risk of gas running out and thus the loss of production time.
Convenient and safe alternative
The system can be installed simply within a compressor house or production area with standard piping, eliminating the need
for any special requirements. In addition, low maintenance requirements ensure minimal production downtime. Nitrogen is produced at low pressure, eliminating safety hazards usually associated with high pressure cylinder gas. Potential manual handling concerns are also removed.
Liquid Nitrogen Generator Maxigas
Liquid Nitrogen Generator Maxigas from Parker produce nitrogen gas from compressed air and offer a cost-effective, reliable and safe alternative to traditional nitrogen gas supplies such as cylinder or liquid. Nitrogen is used as a clean, dry, inert gas primarily for removing oxygen from products and/or processes.
MAXIGAS provides an on-demand, continuous source of nitrogen gas which can be used in a wide range of industries such as food, beverage, pharmaceutical, laboratory, chemical, heat treatment, electronics, transportation, oil and gas and laser cutting.
Click here to download full catalog MAXIGAS_Cat_174004704.pdf
The price includes complete unit and Installation at users desired location all across Pakistan.
Click here to see our full range of Liquid Nitrogen Gas and Containers
Features:
• Can operate from a standard factory compressed air supply
• Delivers 5% down to 10 ppm oxygen content, without the need for any additional purification
• Available in 7 models offering varying flow rates and purities.
• Automatic economy mode
• Built-in oxygen analyzer for continuous purity monitoring
• Digital and analogue outputs for remote monitoring
• Alarm capabilities
• User friendly control interface
• Compact design
• Modular concept
Benefits:
Up to 90% cost savings*
Typical capital pay-back is achievable within 12-24 months.
Energy savings
Low air consumption provides greater energy efficiency.
Convenient and safe
The easy to use system is simple to install, requires minimal maintenance and eliminates safety hazards associated with
traditional gas supplies.
Space saving design
The compact design means the system demands less floor space.
Flexible multi-bank option
The modular concept means the generators can be mutli-banked if required.
Reduce carbon footprint
The elimination of cylinder deliveries and transportation means carbon footprint can be reduced.
Cost-effective, energy saving solution
In addition to a short pay-back period, the cost-effective solution removes costs associated with traditional gas supplies including refills, order processing, tank rental and delivery charges and eliminates future gas company price increases. While operating from a standard compressed air supply, the economy mode and on-demand function respectively offers control over nitrogen production, flow rates and purity levels and therefore limits costly wasted gas or liquid boil off to
facilitate excellent energy savings. The 24/7 operation also removes the risk of gas running out and thus the loss of production time.
Convenient and safe alternative
The system can be installed simply within a compressor house or production area with standard piping, eliminating the need
for any special requirements. In addition, low maintenance requirements ensure minimal production downtime. Nitrogen is produced at low pressure, eliminating safety hazards usually associated with high pressure cylinder gas. Potential manual handling concerns are also removed.
You must be logged in to post a review.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
Automatic Medical Gas Manifold Plant
Automatic Medical Gas Manifold Plant
Precision UK’s CPX Automatic Medical Gas Manifold Plant is manufactured under BS EN 13485 Medical Devices: Quality Management Systems. It provides a centralized source of bottled gas. The unit is designed to provide a duty and standby gas supply at a constant pressure via two banks of bottled gas cylinders with status monitoring. Specification:- A standard system would feature a central control panel with a header assembly.
- Digital display of bottle pressure for duty and standby banks.
- Electronic control with alarm and BMS outputs for remote status indication.
- The unit is designed for wall mounting as standard, however, options available include floor mounted assemblies and formats to suit customer requirements.
- Also available is a high flow capable of providing a distribution flow rate up to 2500l/min.
- Options – Touchscreen, BMS Modbus Digital Outputs, SMS Texting Alarm
- Designed to meet the requirements of:
- HTM 02-01 and SHTM 02-01: Medical Gas Pipeline Systems
- BS EN 7396: Pipeline Systems for Compressed Medical Gases and Vacuum
- C11 NHS: Model Engineering Specification – Medical Gases
- BS EN 10524-2 : Pressure Regulators
- BS EN 21969 High Pressure Flexible Connectors
- CE marked under Medical Device Directive 93/42/EEC with approval from British Standards Institute CE0086 classified as Class IIb Medical Device
Design and planning of CSSD
Designing and Planning of Dialysis unit
Designing and Planing of Dialysis Unit
Designing and Planing of Dialysis Unit in Kidney center is very important. We keep the record of all dialysis units and kidney centers so that we design, plan and manufacture the whole dialysis unit in very low prices for more information and specification please contact 0322-4602203Designing and Planning of Nursery
Designing and Planning of Nursery
Designing and Planning of Nursery in Hospital(s) nurseries are also very important infrastructure for the new born babies. We have ample experience in manufacturing, installing and importing the hospital nursery equipment. Our qualified staff is expert in manufacturing the whole pediatrics ward including all the equipment required therein. please contact for more information 0322-4602203Designing Planning of Central Supply Medical Gases
Designing Planning of Central Supply Medical Gases
For Designing Planning of Central Supply Medical Gases.we design and plan the latest 3D drawings using auto-cad. Our designing department communicate with our potential clients and provides best design and plan as per the discretion of our customers. which is also compatible with the dimensions of their premise. We have a lot to tell you. Please contact us for more information 0322-4602203Hermetic Doors
Hermetic Doors
Hermetic Doors also known as Hermetic sliding door or automatic doors are required where hygiene and the leakage of air control is critical. These doors takes less space and sealed completely form the edges so no air, gases or dust particles can pass through out of the operation theater. We have best team in market to install these doors with top quality material at very competitive prices. For further queries feel free to contact us 0322-4602203Manual/Semi Automatic Manifold Systems
Manual/Semi Automatic Manifold Systems
Manual/Semi Automatic Manifold Systems main using at small and medium hospitals. When using the medical gas oxygen manifold, several cylinders need to be connected to the manifold pipeline. The oxygen gas is first filtered and decompressed, and then transported through the main pipe to the end of use. The function of the secondary regulator is to stabilize the outlet gas flow of the main pipeline. CGA standard adapter port and inlet connection thread. Cleaned for medical Oxygen, Air, N2O, CO2 gas. Open type manifold connector cylinder number according to the client request. 3 years warranty. Specifications:- Applicable gas: O2, Air, CO2, N2, and N2O etc.
- High flow capacity regulator
- Open style cylinder number according to the client request
- Pass the pressurization testing, welded in silver, much safety and stable
- Wall mount simplifies installation, easy installed
- Size of the connecting hose is customized
- CGA4.1 and ISO15001 Standard
- Maximum pressure 3,000 psi
General Information:
An oxygen manifold system is a critical component in the delivery of oxygen in medical facilities. The system consists of a series of oxygen cylinders connected to a common manifold, which regulates the flow of oxygen to different parts of the hospital or clinic. The manifold system ensures a continuous supply of oxygen to patients, even if one cylinder runs out of gas. The manifold system is designed to be reliable and durable, and it is typically made of high-quality materials that can withstand the high pressures of oxygen gas. The manifold system can be configured in different ways depending on the specific needs of the medical facility. For example, some manifold systems may be designed to supply oxygen to a single ward or room, while others may supply oxygen to multiple floors of a hospital. One of the benefits of an oxygen manifold system is its ability to provide a centralized source of oxygen, which can reduce the need for multiple oxygen tanks scattered throughout a facility. This can make it easier to manage the inventory of oxygen tanks and reduce the risk of running out of oxygen during a medical emergency. Overall, an oxygen manifold system is an essential component of any medical facility that requires a reliable supply of oxygen for patient care. Proper maintenance and monitoring of the system are crucial to ensure its continued reliability and safety. Manufactured by AMCAREMEDÂ Please click to read Medical Gas and Pipeline Network For more information please feel free to call us at+92-322-4602203 or Email: info@ziarenterprises.com, zirarenterprises@gmail.comMedical Gas Outlets Precision UK
Medical Gas Outlets Precision UK
Medical Gas Outlets Precision UK also known as CPX Terminal Units are designed and manufactured in the UK under BS EN 13485 Medical Devices: Quality Management Systems. The units comprise of a first fix, second fix and a second fix valve assembly and connect medical appliances to the gas supply system. Please also see our Medical Gas Outlets Precision UK & Medical Gases & Infrastructure The first fix comprises of a brass pipeline termination cylinder with a 12mm BS EN 13348 copper pipe for brazing to the fixed pipeline system, or with a NIST BS EN 18082 (non-interchangeable screw thread) connector for connection to a hose assembly. A mounting box suitable for both surface and flush installations is also provided. CPX British Standard and DIN Standard Gas Outlets utilize a common first fix assembly. The CPX Terminal Unit is designed to enable gas probes to be connected and disconnected easily and with minimal effort and the same time as giving a strong, reliable and secure connection. They are available for oxygen, nitrous oxide, 50% oxygen/50% nitrous oxide mixture, medical air, surgical air, medical vacuum, carbon dioxide, nitrogen and AGSS. The terminal units can be flexibly integrated into any type of installation including surface, flush, bedhead and pendant and are supplied with a 3 year warranty. Test plugs are included with flush, surface, and bedhead types for first fix pressure testing on site. DIN Standard CPX DIN gas outlets are manufactured and designed in our UK factory, full metal construction, Gas Indexing as EN 13260-2, EN 9170 and Medical Gas Pipelines EN 7396.
Standards: Designed to Meet the requirements of
Medical Gas Outlet Precision UK
- HTM 02-01 Medical gas Pipeline Systems
- BS EN 7396-1 Pipelines for Compressed medical Gases and Vacuum
- BS EN 7396-2 Anaesthetic Gas Scavenging Disposal Systems
- BS EN 9170-1 Terminal Units for use with Compressed Medical Gases and Vacuum
- BS EN 9170-2 Terminal Units for Anaesthetic Gas Scavenging Systems
- C11 NHS Model Engineering Specification – Medical Gases
- BS EN 18082 Non-interchangeable Screw Threaded (NIST) Low-pressure Connectors for Medical Gases
- BS 5682 Specification for Probes Specification for Probes (quick connectors) for Medical Gases.
- Medical Device Directive 93/42/EEC (CE0086) Class IIb.
- DIN 13260-2 Part 2: Dimensions and allocation of Probes and Gas specific connection points for Terminal Units
- Available for Oxygen, Nitrous Oxide, Medical Air, CO2, Motor Air and Vacuum (other gases available on request)
- Incorporating a 12mm copper stub pipe to EN 13348 to allow easy connection to the Medical Gas Pipeline system, other options include NIST or DISS type fittings for pendants or bed head units.
- Probe insertion design incorporates parking position and full insert for 100% operation, each outlet is supplied with Flush/Surface Box or Bed Head Plate mounting options and include a 3-year warranty.
- CE marked CE0086 Class IIb Medical Device.

Reviews
There are no reviews yet.