Multiparameter Patient Monitor MD9000s Meditech
Multiparameter Patient Monitor MD9000s Meditech
Multiparameter Patient Monitor MD9000s Meditech patient monitor has a 12.1″color TFT screen. Monitoring ECG, SP02, NIBP, RESP .2-TEMP. PR as standard parameters, and 2-IBP, ETC02 and thermal printer as optional. MD9000s is one of its kind and the best selling patient monitor in Europe.
Features:
- 12.1” TFT color LCD, multi-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakh, Polish, Czech).
- Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
- All-round monitor for adult, pediatric and neonate.
- With standard interface, oxygen graph, trend graph, big character interface and view bed, convenient to observe.
Finish all operations by keys and knobs. - Maximum 8-channel waveform synchronous display.
- Display 7-lead ECG waveform on one screen, cascade ECG waveform display
- Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
- Heart rate variability (HRV) analysis function
- NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.
- Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
- Drug concentration calculation and titration table functions.
- One-touch printing of trend graph
- Connect to Central Monitoring System by 3G, Wi-Fi or wired mode.
- AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
- Anti-high frequency surgical unit, defibrillation-proof (special leads are necessary).
Options:
- Invasive Blood Pressure (IBP)
- Carbon dioxide (CO2) Module
- Masimo SpO2 Module
- Thermal Printer
Specification:
ECG
Lead Mode 5 Leads ( R, L, F, N, C or RA, LA, LL, RL, V)
Lead selection I, II, III, avR, avL, avF, V,
Waveform 2 ch
Lead mode 3 Leads ( R, L, F or RA, LA, LL)
Lead selection I, II, III,
Waveform 1 ch
Gain ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV
HR and Alarm
Range
Adult 30 ~ 300 bpm
Neo/Ped 30 ~ 350 bpm
Accuracy ±1% or ±1bpm, which great
Resolution 1 bpm
Sensitivity > 200 uV P-P
Differential Input Impedance > 5 MΩ
CMRR
Monitor > 105 dB
Operation > 105 dB
Diagnosis > 85 dB
Electrode offset potential ±300mV
Leakage Current < 10 uA
Baseline Recovery < 10 s After Defi.
ECG Signal Range ±8 mV (Vp-p)
Bandwidth
Surgery 1 ~ 15 Hz
Monitor 0.5 ~ 35 Hz
Diagnostic 0.05 ~ 100 Hz
Calibration Signal 1 mV (Vp-p), ±5% Accuracy
ST Segment Monitoring Range
Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting
Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm Available
Review Available
Tall T-wave rejection capability 1.2mV
Heart rate averaging the average value of the latest 6 R-R intervals which have ignored the maximum and minimum
Updating rate of the display 1s
Heart rate meter accuracy and response to irregular rhythm:
Bigeminy ventricular 80bpm
Bigeminy ventricular alternative lente 57 or 63bpm
Bigeminy ventricular alternative rapid 122 or 123bpm
Systoles bidirectional 95bpm
Response time to heart rate meter to change in heart rate 80 to 120bpm
Average 3.7s
Range 3.2s ~ 4.1s 80 to 40bpm
Average 4.7s
NIBP
Method Oscillometric
Mode Manual, Auto, STAT
Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120,240,480,960Min
Measuring Period in STAT Mode 5 Min
Pulse Rate Range 40 ~ 240 bpm
Alarm Type SYS, DIA, MEAN
Measuring and alarm Range
Adult Mode
SYS 40 ~ 270 mmHg
DIA 10 ~ 215 mmHg
MEAN 20 ~ 235 mmHg
Pediatric Mode
SYS 40 ~ 200 mmHg
DIA 10 ~ 150 mmHg
MEAN 20 ~ 165 mmHg
Neonatal Mode
SYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHg
Resolution
Pressure 1mmHg
Accuracy
Pressure
Maximum Mean error ±5mmHg
Maximum Standard deviation ±8mmHg
Overpressure Protection
Adult Mode 297±3 mmHg
Pediatric Mode 240±3 mmHg
Neonatal Mode 147±3 mmHg
TEMPERATURE
Channel 2
Measuring and Alarm Range 0 ~ 50 °C
Resolution 0.1°C
Accuracy ±0.1°C
Actualization interval about 1 Sec.
Average Time Constant < 10 Sec.
IBP (optional)
Channel 2
Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART 0~300mmHg
PA -6~120mmHg
CVP/RAP/LAP/ICP -10~40mmHg
P1~P2 -10~300mmHg
Press Sensor
Sensitivity 5 uV/V/mmHg
Impedance 300-3000Ω
Resolution 1mmHg
Accuracy ±2% or 1mmHg which great
Actualization Interval about 1 Sec
Display
Device
12.1 in. Color TFT Made by Sharp Japan
Messages
7 Waveforms Maximum
1 Alarm LED ( Yellow/Red)
Screenshot 1 Power LED (Green)
1 Battery Charge LED ( Yellow)
3 Sound Mode corresponding Alarm Mode
Signal Interface
ECG Output BNC
Amplitude 1 V/mV
Accuracy < 5 %
Impedance 50 Ω
Signal Delay < 20 mS
Recall
Trend Recall
Short 1 hrs, 1 Second Resolution
Long 72 hrs, 1 Min. Resolution
Alarm Event Recall
71 alarm events of all parameters and 8/16/32seconds of corresponding waveform.
NIBP Measurement Recall
At least 400 NIBP measurement data.
Battery
Rechargeable 3.7 A/Hr 7.4V Li battery
Operating time under the normal use and full charge greater than 180minutes
Operating time after the first alarm of low battery will be about 5 minutes
Recorder (Option)
Record Width 48 mm
Paper Speed 25/50 mm/S
Trace 2
Size and Weight
Size Monitor 310 x 140 x 263 mm
Weight Monitor 3.8 kg
Multiparameter Patient Monitor MD9000s Meditech
Multiparameter Patient Monitor MD9000s Meditech patient monitor has a 12.1″color TFT screen. Monitoring ECG, SP02, NIBP, RESP .2-TEMP. PR as standard parameters, and 2-IBP, ETC02 and thermal printer as optional. MD9000s is one of its kind and the best selling patient monitor in Europe.
Features:
- 12.1” TFT color LCD, multi-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakh, Polish, Czech).
- Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
- All-round monitor for adult, pediatric and neonate.
- With standard interface, oxygen graph, trend graph, big character interface and view bed, convenient to observe.
Finish all operations by keys and knobs. - Maximum 8-channel waveform synchronous display.
- Display 7-lead ECG waveform on one screen, cascade ECG waveform display
- Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
- Heart rate variability (HRV) analysis function
- NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.
- Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
- Drug concentration calculation and titration table functions.
- One-touch printing of trend graph
- Connect to Central Monitoring System by 3G, Wi-Fi or wired mode.
- AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
- Anti-high frequency surgical unit, defibrillation-proof (special leads are necessary).
Options:
- Invasive Blood Pressure (IBP)
- Carbon dioxide (CO2) Module
- Masimo SpO2 Module
- Thermal Printer
Specification:
ECG
Lead Mode 5 Leads ( R, L, F, N, C or RA, LA, LL, RL, V)
Lead selection I, II, III, avR, avL, avF, V,
Waveform 2 ch
Lead mode 3 Leads ( R, L, F or RA, LA, LL)
Lead selection I, II, III,
Waveform 1 ch
Gain ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV
HR and Alarm
Range
Adult 30 ~ 300 bpm
Neo/Ped 30 ~ 350 bpm
Accuracy ±1% or ±1bpm, which great
Resolution 1 bpm
Sensitivity > 200 uV P-P
Differential Input Impedance > 5 MΩ
CMRR
Monitor > 105 dB
Operation > 105 dB
Diagnosis > 85 dB
Electrode offset potential ±300mV
Leakage Current < 10 uA
Baseline Recovery < 10 s After Defi.
ECG Signal Range ±8 mV (Vp-p)
Bandwidth
Surgery 1 ~ 15 Hz
Monitor 0.5 ~ 35 Hz
Diagnostic 0.05 ~ 100 Hz
Calibration Signal 1 mV (Vp-p), ±5% Accuracy
ST Segment Monitoring Range
Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting
Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm Available
Review Available
Tall T-wave rejection capability 1.2mV
Heart rate averaging the average value of the latest 6 R-R intervals which have ignored the maximum and minimum
Updating rate of the display 1s
Heart rate meter accuracy and response to irregular rhythm:
Bigeminy ventricular 80bpm
Bigeminy ventricular alternative lente 57 or 63bpm
Bigeminy ventricular alternative rapid 122 or 123bpm
Systoles bidirectional 95bpm
Response time to heart rate meter to change in heart rate 80 to 120bpm
Average 3.7s
Range 3.2s ~ 4.1s 80 to 40bpm
Average 4.7s
NIBP
Method Oscillometric
Mode Manual, Auto, STAT
Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120,240,480,960Min
Measuring Period in STAT Mode 5 Min
Pulse Rate Range 40 ~ 240 bpm
Alarm Type SYS, DIA, MEAN
Measuring and alarm Range
Adult Mode
SYS 40 ~ 270 mmHg
DIA 10 ~ 215 mmHg
MEAN 20 ~ 235 mmHg
Pediatric Mode
SYS 40 ~ 200 mmHg
DIA 10 ~ 150 mmHg
MEAN 20 ~ 165 mmHg
Neonatal Mode
SYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHg
Resolution
Pressure 1mmHg
Accuracy
Pressure
Maximum Mean error ±5mmHg
Maximum Standard deviation ±8mmHg
Overpressure Protection
Adult Mode 297±3 mmHg
Pediatric Mode 240±3 mmHg
Neonatal Mode 147±3 mmHg
TEMPERATURE
Channel 2
Measuring and Alarm Range 0 ~ 50 °C
Resolution 0.1°C
Accuracy ±0.1°C
Actualization interval about 1 Sec.
Average Time Constant < 10 Sec.
IBP (optional)
Channel 2
Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART 0~300mmHg
PA -6~120mmHg
CVP/RAP/LAP/ICP -10~40mmHg
P1~P2 -10~300mmHg
Press Sensor
Sensitivity 5 uV/V/mmHg
Impedance 300-3000Ω
Resolution 1mmHg
Accuracy ±2% or 1mmHg which great
Actualization Interval about 1 Sec
Display
Device
12.1 in. Color TFT Made by Sharp Japan
Messages
7 Waveforms Maximum
1 Alarm LED ( Yellow/Red)
Screenshot 1 Power LED (Green)
1 Battery Charge LED ( Yellow)
3 Sound Mode corresponding Alarm Mode
Signal Interface
ECG Output BNC
Amplitude 1 V/mV
Accuracy < 5 %
Impedance 50 Ω
Signal Delay < 20 mS
Recall
Trend Recall
Short 1 hrs, 1 Second Resolution
Long 72 hrs, 1 Min. Resolution
Alarm Event Recall
71 alarm events of all parameters and 8/16/32seconds of corresponding waveform.
NIBP Measurement Recall
At least 400 NIBP measurement data.
Battery
Rechargeable 3.7 A/Hr 7.4V Li battery
Operating time under the normal use and full charge greater than 180minutes
Operating time after the first alarm of low battery will be about 5 minutes
Recorder (Option)
Record Width 48 mm
Paper Speed 25/50 mm/S
Trace 2
Size and Weight
Size Monitor 310 x 140 x 263 mm
Weight Monitor 3.8 kg
You must be logged in to post a review.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
12 Channel ECG Cardio7 Bionet
12 Channel ECG Cardio7 Bionet
12 Channel ECG Cardio7 Bionet device is classified as follows, in accordance with IEC60601-1. There are a lot of ECG Machines in the market but the reputation of Bionet is absolutely phenomenal, please bear in mind that Bionet is USA Based company but the products are manufactured in Korea. However each and every single product is FDA Approved. 12 Channel ECG Cardio7 Bionet device or system is suitable for use in all establishments other than domestic and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. Mains power should be a typical commercial or hospital environment. For more information regarding the product please feel free to contact us.CLICK HERE TO DOWNLOAD THE CATALOG Bionet Cardio7_ECG.pdf
Features:
12 channel interpretive ECG for adult, pediatric and neonatal use over 130 kinds of interpretation results based on advanced Minnesota code, HRV (Hearth Rate Variability analysis)- memory for up to 200 patients
- real-time preview monitor
- PC compatible through LAN or Wi-Fi
- multi-Ianguage selectable software (GB, RU, FR, DE, IT, CN, ES, TU, PL, RU, PT)
- lead fault message
- pace maker detection
- automatic arrhythmia detection
- 3, 5, 10 minutes long term recording
- grid function allows you to use low cost plain fax paper
- wide and clear colour 7” TFT LCD (800x480)
- touch screen for easy operation
- full disclosure function
Specification:
ECG leads: 10 lead, 12 channel simultaneous ECG and acquisition • Dimension: 300(W) x 299(H) x 123(D)mm, approx. 3.5 kg • Recording channel: 3 channels + 1 rhythm, 3 channels + 3 rhythm, 6 channels + 1 rhythm, 12 channels, 60 seconds 1 channel, 3, 5, 10 minutes 1 channel and beat report • Sensitivity: 2.5, 5, 10, 20, auto (l~aVF: 10, V1~V6: 5) mm/mV • Printing speed: 5, 12.5, 25, 50, 100 mm/s • Sampling rate: 2,000 samples/sec • Filters: AC (50/60 Hz, -20 dB or better) • Muscle (25~35 Hz, -3dB or better) • Base line drift (0.05, 0.1, 0.2 Hz, -3dB or better) • Low pass filter: off, 40 Hz, 100 Hz, 150 Hz • Display: 7" color TFT LCD display (800x480), 12 channels preview ECG wave • Monitor display: ID, date, sensitivity, speed, filter, form, rhythm lead • User interface: Touch screen (alphanumeric and symbol available), Keyboard, rotary push-knob (pop-up menu) • Patient data: ID, name, age, sex, height, weight, smoke, race • Basic measurement: Heart rate, PR int, QRS dur, QT/QTc, P-R-T axis • Recorder: Thermal print head, roll paper, A4 report paper: 210x300 mm (8.5"x11") • Resolution: - Vertical: 8 dot/mm - Horizontal: 16 dot/mm • Electrical: - Internal noise: 20 µV (p-p) max - Input circuit: floating input - Input impedance: =50 MO - Input voltage range: = ±5 mV - Common mode rejection: > 105 dB - DC offset voltage: = ±400 mV - Time constant: 3.2 sec - Patient leakage current: < 10 µA - Frequency response: 0.05 ~150 Hz - Isolated and defibrillation protected • Signal quality control: Disconnected lead detection, Pacemaker pulse detection • ECG data storage: storage for 200 ECGs (Internal on flash memory) • Power: 100~240 VAC, 50/60 Hz or battery (option) 2.0~1.0 A, 60 VA max • Battery (Li-Ion): 4 hours of normal use (approx.200 ECG printouts) • Communication: PC connection with LAN D2 Wi-Fi • Safety conformity: Class I, Type CF, CE, CSA, FDA, KFDA, CFDA, CCC General Information of 12 Channel ECG Cardio7 Bionet For more information regarding ecg machine price in Pakistan, 3 channel ecg machine price in Pakistan or 12 channel ecg price in Pakistan please feel free to contact us. Our technical staff will provide you full back-up and support in all over Pakistan. When talk about ecg price in Pakistan or ecg machine price in Pakistan we are the number one company in entire Pakistan to provide ECG Machines in Pakistan, ETT Machines in Pakistan, Patient Monitors in Pakistan, Cardiac Monitors in Pakistan, AED in Pakistan, Defibrillator in Pakistan and almost all type of Cardiology Equipment in Pakistan.Automated Hematology Analyzer DC 2400 Plus
Automated Hematology Analyzer DC 2400 Plus
Automated Hematology Analyzer DC 2400 Plus is one of the best Fully automated hematology analyzer which can perform two duties at the same time monitoring of the blood cells having diseased cells and at the same time counting them. DiA CELL DC-2400 PLUS is very useful machine for the patients, laboratory staff etc, some of the features are: Features:- Perfect QA
- Simple to Operate
- Convenient Maintenance
- Advanced Design
Carry Over: RBC, WBC, HGB <0.5%, PLT<1.0%
Operating Interface: Colorful Windows interface, no need connecting computer. Operating by graphic button with mouse and keyboard
Display: Big size 10.4’’ TFT LCD, all parameters and histograms displayed in the same screen
Print Mode: Internal high-speed thermal printer. Optional connection with specified external printer. English printouts
Reagents System: Open reagent system. No cyanogen reagents. Provide original reagents.
Connection Port: USB, RS-232, network interface
Power: Maximum 150VA
Environment: Temperature 10℃-35℃. Relative humidity: 10%-90%
Power Supply: 220(1±10%)V, (50±1)Hz. 90V-260V, 50-60Hz broad range power available for different Countries
Dimension: 520mm×460mm×420mm
Weight: 23Kg
Patient Monitor Operon OM12
Patient Monitor Operon OM12
Specification:- 12" inched LCD Monitor with high brightness TFT colors
- VGA slot available for attaching high resolution screen such as LED's, Monitors Etc
- SPO2
- Alarm/Beep as per prescribed statistics of the patient
- Accurate Blood Pressure display.
- Heart Beat display
- Printable ECH and other statistics/diagnosis.
Patient Monitor Truscope ll Schiller
Patient Monitor Truscope ll Schiller
Patient Monitor Truscope ll Schiller is a Multi-ParaMeter Patient Monitor this Lightweight Modular Patient monitor is equipped with a 12.1" high resolution color TFT LCD display, Offering the parameters ECG, RESP, NIBP, TEMP and SPO2. please click on the link to download product brochure MULTI PARAMETER PATIENT MONITOR TRUSCOPE II.pdf For More information please call +92-322-4602203 or Email: zirarenterprises@gmail.com, info@zirarenterprises.com FEATURES:- 12.1" high resolution color TFT LCD display
- Critical parameters ECG, SpO2, NIBP, Temp, Resp monitored
- 12 lead ECG waveform display & total 11 waveforms display
- ST analysis, arrhythmia analysis
- Digital SpO2 even for low perfusion cases
- 72 hours tabular and graphical trends & data storage
- Drug dose calculation software
- OXYCRG software
- Certification: CE 0123, FDA
- Upgradable to 12 lead, dual IBP, thermal recorder, ETCO2, Multigas (CO2, O2, N2O and 5 Anaesthetic Agent) & second temperature (rectal)
- Nellcor technology for pulse oximetry
- Video Output (VGA)
- CNS: Wired / Wireless
- Upgradable to 12 lead, dual IBP, thermal recorder, ETCO2, Multigas (CO2, O2, N2O and 5 Anaesthetic Agent) & second temperature (rectal)
- Nellcor technology for pulse oximetry
- Video Output (VGA)
- CNS: Wired / Wireless