Oxygen Nitrous Oxide Medical Air Plant
Oxygen Nitrous Oxide Medical Air Plant
Oxygen Nitrous Oxide Medical Air Plant Medical Gas Cylinder central Plant stations are installed to provide a reliable source of supply for the Oxygen, Nitrous Oxide & Medical Air requirements of hospitals. Principal details of these Plants are usually similar. The only difference is the number of cylinders which are used in the Plants. These pressured gases are used in Operation Theaters, Intensive Care Units, Baby Care Units, Emergency Rooms and Patient Rooms.
The gas is stored at high pressure in specifically made cylinders that are connected to the Central Plant Station. The pressure in the cylinder will vary according to the gas contained in the cylinder (O2, – N2O. Air). This Plant has been designed and built specially for hospitals to comply fully with ISO 7396:2004, ISO 13485:2003, EN 46001, ISO 14971, EN 980, EN 940, EN 739, EN 737, EN 793, DIN 13260, HTM 2022 and American Standards and is CE Marked. These Plants are manufactured in compliance to ISO 9001:2000, ISO 13485:2001, EN 46001, EN 1441:1997, EN 980,EN 940, EN 739, EN 737 ,EN 793, DIN 13260, HTM 2022, American Standards and CE Marked.
Manufactured by: Medikar, Turkey
Please check our complete range of Medical Gases and Pipe Network
The Plants are proposed according to the hospital capacity as follows:
- Automatic (Oxygen, Nitrous Oxide, Medical Air ) Plant Auto System 8200
- Automatic (Oxygen, Nitrous Oxide, Medical Air ) Plant Auto System 8001
- Manual Plant
- Emergency Supply Plant System
For more information quotations, queries and rates please call or whatsapp +92-322-4602203 Email: info@zirarenterprises.com, zirarenterprises@gmail.com
Oxygen Nitrous Oxide Medical Air Plant
Oxygen Nitrous Oxide Medical Air Plant Medical Gas Cylinder central Plant stations are installed to provide a reliable source of supply for the Oxygen, Nitrous Oxide & Medical Air requirements of hospitals. Principal details of these Plants are usually similar. The only difference is the number of cylinders which are used in the Plants. These pressured gases are used in Operation Theaters, Intensive Care Units, Baby Care Units, Emergency Rooms and Patient Rooms.
The gas is stored at high pressure in specifically made cylinders that are connected to the Central Plant Station. The pressure in the cylinder will vary according to the gas contained in the cylinder (O2, – N2O. Air). This Plant has been designed and built specially for hospitals to comply fully with ISO 7396:2004, ISO 13485:2003, EN 46001, ISO 14971, EN 980, EN 940, EN 739, EN 737, EN 793, DIN 13260, HTM 2022 and American Standards and is CE Marked. These Plants are manufactured in compliance to ISO 9001:2000, ISO 13485:2001, EN 46001, EN 1441:1997, EN 980,EN 940, EN 739, EN 737 ,EN 793, DIN 13260, HTM 2022, American Standards and CE Marked.
Manufactured by: Medikar, Turkey
Please check our complete range of Medical Gases and Pipe Network
The Plants are proposed according to the hospital capacity as follows:
- Automatic (Oxygen, Nitrous Oxide, Medical Air ) Plant Auto System 8200
- Automatic (Oxygen, Nitrous Oxide, Medical Air ) Plant Auto System 8001
- Manual Plant
- Emergency Supply Plant System
For more information quotations, queries and rates please call or whatsapp +92-322-4602203 Email: info@zirarenterprises.com, zirarenterprises@gmail.com
You must be logged in to post a review.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
Automatic Medical Gas Manifold Plant
Automatic Medical Gas Manifold Plant
Precision UK’s CPX Automatic Medical Gas Manifold Plant is manufactured under BS EN 13485 Medical Devices: Quality Management Systems. It provides a centralized source of bottled gas. The unit is designed to provide a duty and standby gas supply at a constant pressure via two banks of bottled gas cylinders with status monitoring. Specification:- A standard system would feature a central control panel with a header assembly.
- Digital display of bottle pressure for duty and standby banks.
- Electronic control with alarm and BMS outputs for remote status indication.
- The unit is designed for wall mounting as standard, however, options available include floor mounted assemblies and formats to suit customer requirements.
- Also available is a high flow capable of providing a distribution flow rate up to 2500l/min.
- Options – Touchscreen, BMS Modbus Digital Outputs, SMS Texting Alarm
- Designed to meet the requirements of:
- HTM 02-01 and SHTM 02-01: Medical Gas Pipeline Systems
- BS EN 7396: Pipeline Systems for Compressed Medical Gases and Vacuum
- C11 NHS: Model Engineering Specification – Medical Gases
- BS EN 10524-2 : Pressure Regulators
- BS EN 21969 High Pressure Flexible Connectors
- CE marked under Medical Device Directive 93/42/EEC with approval from British Standards Institute CE0086 classified as Class IIb Medical Device
Designing and planning of CCU
Designing and planning of ICU
Designing and planning of ICU
For Designing and planning of ICU. We have one best expertise in designing and planning of intensive care unit (ICU) we have ample experience in this category. We already manufactured and installed it to one of the best and renowned hospitals nation wide for more information please contact 0322-4602203Designing Planning of Central Supply Medical Gases
Designing Planning of Central Supply Medical Gases
For Designing Planning of Central Supply Medical Gases.we design and plan the latest 3D drawings using auto-cad. Our designing department communicate with our potential clients and provides best design and plan as per the discretion of our customers. which is also compatible with the dimensions of their premise. We have a lot to tell you. Please contact us for more information 0322-4602203Manual/Semi Automatic Manifold Systems
Manual/Semi Automatic Manifold Systems
Manual/Semi Automatic Manifold Systems main using at small and medium hospitals. When using the medical gas oxygen manifold, several cylinders need to be connected to the manifold pipeline. The oxygen gas is first filtered and decompressed, and then transported through the main pipe to the end of use. The function of the secondary regulator is to stabilize the outlet gas flow of the main pipeline. CGA standard adapter port and inlet connection thread. Cleaned for medical Oxygen, Air, N2O, CO2 gas. Open type manifold connector cylinder number according to the client request. 3 years warranty. Specifications:- Applicable gas: O2, Air, CO2, N2, and N2O etc.
- High flow capacity regulator
- Open style cylinder number according to the client request
- Pass the pressurization testing, welded in silver, much safety and stable
- Wall mount simplifies installation, easy installed
- Size of the connecting hose is customized
- CGA4.1 and ISO15001 Standard
- Maximum pressure 3,000 psi
General Information:
An oxygen manifold system is a critical component in the delivery of oxygen in medical facilities. The system consists of a series of oxygen cylinders connected to a common manifold, which regulates the flow of oxygen to different parts of the hospital or clinic. The manifold system ensures a continuous supply of oxygen to patients, even if one cylinder runs out of gas. The manifold system is designed to be reliable and durable, and it is typically made of high-quality materials that can withstand the high pressures of oxygen gas. The manifold system can be configured in different ways depending on the specific needs of the medical facility. For example, some manifold systems may be designed to supply oxygen to a single ward or room, while others may supply oxygen to multiple floors of a hospital. One of the benefits of an oxygen manifold system is its ability to provide a centralized source of oxygen, which can reduce the need for multiple oxygen tanks scattered throughout a facility. This can make it easier to manage the inventory of oxygen tanks and reduce the risk of running out of oxygen during a medical emergency. Overall, an oxygen manifold system is an essential component of any medical facility that requires a reliable supply of oxygen for patient care. Proper maintenance and monitoring of the system are crucial to ensure its continued reliability and safety. Manufactured by AMCAREMED Please click to read Medical Gas and Pipeline Network For more information please feel free to call us at+92-322-4602203 or Email: info@ziarenterprises.com, zirarenterprises@gmail.comMedical Gas Outlets Medikar
Medical Gas Outlets Medikar
Medical Gas Outlets Medikar Q-Click gas outlet to the hospital by the medical gas supply unit to connected copper pipe and brought to the patient are the end points. Probes inserted into the socket with the relevant gas check valves are opened and gas will start crossing. Valve opens and gas locking mechanism to suppress the transition and the probe is removed and cut. Gas outlet pipe of the Q-Click base, capsule type, the main body consists of three groups. Q-Click Gas Connectors BS 5682:1998, ISO 9170:2008, EN 737, ISO 9001:2000 and are designed according to the norms of MDD 93/42/EEC. Q-Click Gas outlet other than a standard capsule and a standard to ensure the transition of the main body is enough to change. Easy disassembly and reassembly capability. Maintenance and service is also very simple. Gas outlet in the patient rooms, emergency rooms are used and the maternity ward. Q-Click gas outlet BS 5682:1998, DIN EN 13 260 and 737-6 are manufactured according to the norms. Q-Click gas outlet completely metal aluminum and brass material is manufactured from a durable and sturdy structure. It is also noticeable that we have been supplying wall mounted Oxygen Points in Pakistan for more than two decades and therefore we have ample experience in installation of Oxygen Points or Oxygen Outlets, Air Outlets, Vacuum Outlets and Nitrous Oxide outlet points, we can install it directly on the wall or typically it install on the Bed Head Panel. We have wide range of stock of British Standard Outlet Points, Din Standard Outlet Points or any other type can also be manufactured on prior order. We also manufacture OT Pendants and the outlet for OT Pendants Double Arm and Single Arm and they are 100# Portable.
Manufactured by Medikar Turkey
Please click to see our full Range of Medical Gases & Infrastructure
For more information please feel free to contact us +92-322-4602203 Email: info@zirarenterprises.com, zirarenterprises@gmail.com Medical Gas Outlets Precision UK
Medical Gas Outlets Precision UK
Medical Gas Outlets Precision UK also known as CPX Terminal Units are designed and manufactured in the UK under BS EN 13485 Medical Devices: Quality Management Systems. The units comprise of a first fix, second fix and a second fix valve assembly and connect medical appliances to the gas supply system. Please also see our Medical Gas Outlets Precision UK & Medical Gases & Infrastructure The first fix comprises of a brass pipeline termination cylinder with a 12mm BS EN 13348 copper pipe for brazing to the fixed pipeline system, or with a NIST BS EN 18082 (non-interchangeable screw thread) connector for connection to a hose assembly. A mounting box suitable for both surface and flush installations is also provided. CPX British Standard and DIN Standard Gas Outlets utilize a common first fix assembly. The CPX Terminal Unit is designed to enable gas probes to be connected and disconnected easily and with minimal effort and the same time as giving a strong, reliable and secure connection. They are available for oxygen, nitrous oxide, 50% oxygen/50% nitrous oxide mixture, medical air, surgical air, medical vacuum, carbon dioxide, nitrogen and AGSS. The terminal units can be flexibly integrated into any type of installation including surface, flush, bedhead and pendant and are supplied with a 3 year warranty. Test plugs are included with flush, surface, and bedhead types for first fix pressure testing on site. DIN Standard CPX DIN gas outlets are manufactured and designed in our UK factory, full metal construction, Gas Indexing as EN 13260-2, EN 9170 and Medical Gas Pipelines EN 7396.
Standards: Designed to Meet the requirements of
Medical Gas Outlet Precision UK
- HTM 02-01 Medical gas Pipeline Systems
- BS EN 7396-1 Pipelines for Compressed medical Gases and Vacuum
- BS EN 7396-2 Anaesthetic Gas Scavenging Disposal Systems
- BS EN 9170-1 Terminal Units for use with Compressed Medical Gases and Vacuum
- BS EN 9170-2 Terminal Units for Anaesthetic Gas Scavenging Systems
- C11 NHS Model Engineering Specification – Medical Gases
- BS EN 18082 Non-interchangeable Screw Threaded (NIST) Low-pressure Connectors for Medical Gases
- BS 5682 Specification for Probes Specification for Probes (quick connectors) for Medical Gases.
- Medical Device Directive 93/42/EEC (CE0086) Class IIb.
- DIN 13260-2 Part 2: Dimensions and allocation of Probes and Gas specific connection points for Terminal Units
- Available for Oxygen, Nitrous Oxide, Medical Air, CO2, Motor Air and Vacuum (other gases available on request)
- Incorporating a 12mm copper stub pipe to EN 13348 to allow easy connection to the Medical Gas Pipeline system, other options include NIST or DISS type fittings for pendants or bed head units.
- Probe insertion design incorporates parking position and full insert for 100% operation, each outlet is supplied with Flush/Surface Box or Bed Head Plate mounting options and include a 3-year warranty.
- CE marked CE0086 Class IIb Medical Device.