Patient Monitor MD9012 Meditech
Patient Monitor MD9012 Meditech
Patient Monitor MD9012 Meditech is 12 inch TFT display high resolution. Automatic temperature drift treatment of NIBP measuring patented technology;Friendly and configurable user interface;Powerful data review:Maximum 720-hour graphic and tabular trends, Up to10000 pieces of NIBP record storage, Wired or wireless networkable with Central Monitoring System;On-line upgrading keeps you updated.
Features:
- High resolution 12” color TFT display
- 12 Channel waves.9 Parameters : ECG, Resp, NIBP, SpO2, TEMP,
- Light weight, compact and portable
- Built-in rechargeable lithium battery
- Unique human voice alarm
- Rich screen layouts: Standard, Big font, Trend table, NIBP trend, ECG full lead, OxyCRG, IoC Layout
- Powerful storage: Maximum 720 Hour graphic and tabular trends of all
- parameters, up to 10000 NIBP review, 200 alarm review ,2 Hours of all wave forms
- System software can be upgraded through network
- Data and waveforms color be adjustable
- Arrhythmia analysis and S-T segment analysis
- Suitable for adult, pediatric and neonatal patient
Options:
- Invasive Blood Pressure (IBP)
- Carbon dioxide (CO2) Module
- Thermal Printer
- Touch Screen
Specification:
ECG
Lead Mode 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection I, II, III, avR, avL, avF, V,
Waveform 2 ch
Lead mode 3 Leads ( R, L, F or RA, LA, LL)
Lead selection I, II, III,
Waveform 1 ch
Gain x2.5mm/mV, x5.0mm/mV, x10mm/mV, x20mm/mV, auto
HR and Alarm
Range
Adult 15 ~ 300 bpm
Neo/Ped 15 ~ 350 bpm
Accuracy ± 1% or ± 1bpm,which great
Resolution 1 bpm
Sensitivity > 200 (uV )
Differential Input Impedance > 5 MΩ
CMRR
Monitor > 105 dB
Operation > 105 dB
Diagnosis > 85 dB
Electrode offset potential ±300mV
Leakage Current < 10 uA
Baseline Recovery < 3 S After Defi.
ECG Signal Range ±8 m V ( Vp-p )
Bandwidth
Surgery 1 ~ 15 Hz
Monitor 0.5 ~ 35 Hz
Diagnostic 0.05 ~ 100 Hz
Calibration Signal 1 (mV ), Accuracy :±5%
ST Segment Monitoring Range
Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting
Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY,MISSED BEATS, PNP, PNC
Alarm Available
Review Available
RESPIRATION
Method Impedance between R-F(RA-LL)
Differential Input Impedance >2.5 MΩ
Measuring Impedance Range: 0.3~5.0Ω
Base line Impedance Range: 0 – 2.5 KΩ
Bandwidth 0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range
Adult 0 ~ 120 rpm
Neo/Ped 0 ~ 150 rpm
Resolution 1 rpm
Accuracy ±2 rpm
Apean Alarm 10 ~ 40 S
NIBP
Method Oscillometric
Mode Manual, Auto, STAT
Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
Measuring Period in STAT Mode 5 Min
Pulse Rate Range 40 ~ 240 bpm
Alarm Type SYS, DIA, MEAN
Measuring and alarm range
Adult Mode
SYS 40 ~ 270 mmHg
DIA 10 ~ 215 mmHg
MEAN 20 ~ 235 mmHg
Pediatric Mode
SYS 40 ~ 200 mmHg
DIA 10 ~ 150 mmHg
MEAN 20 ~ 165 mmHg
Neonatal Mode
SYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHg
Resolution
Pressure 1mmHg
Accuracy
Pressure
Maximum Mean error ±5mmHg
Maximum Standard deviation ±8mmHg
Overpressure Protection
Adult Mode 297±3 mmHg
Pediatric Mode 240±3 mmHg
Neonatal Mode 147±3 mmHg
SpO2
Measuring Range 0 ~ 100 %
Alarm Range 0 ~ 100 %
Resolution 1 %
Accuracy 70% ~ 100% ±2 %
0% ~ 69% unspecified
Actualization interval about 1 Sec.
Alarm Delay 10 Sec.
Pulse Rate
Measuring and Alarm Range 0~254bpm
Resolution 1bpm
Accuracy ±2bpm
TEMPERATURE
Channel 1
Measuring and Alarm Range 0 ~ 50 C
Resolution 0.1~C
Accuracy ±0.1~C
Actualization interval about 1 Sec.
Average Time Constant < 10 Sec.
IBP
Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART 0 ~ 300 mmHg
PA -6 ~ 120 mmHg
CVP/RAP/LAP/ICP -10 ~ 40 mmHg
P1/P2 -10 ~ 300 mmHg
Press Sensor
Sensitivity 5 uV/V/mmHg
Impedance 300-3000Ω
Resolution 1 mmHg
Accuracy ±2% or ±1mmHg, which great about 1 Sec.
Patient Monitor MD9012 Meditech
Patient Monitor MD9012 Meditech is 12 inch TFT display high resolution. Automatic temperature drift treatment of NIBP measuring patented technology;Friendly and configurable user interface;Powerful data review:Maximum 720-hour graphic and tabular trends, Up to10000 pieces of NIBP record storage, Wired or wireless networkable with Central Monitoring System;On-line upgrading keeps you updated.
Features:
- High resolution 12” color TFT display
- 12 Channel waves.9 Parameters : ECG, Resp, NIBP, SpO2, TEMP,
- Light weight, compact and portable
- Built-in rechargeable lithium battery
- Unique human voice alarm
- Rich screen layouts: Standard, Big font, Trend table, NIBP trend, ECG full lead, OxyCRG, IoC Layout
- Powerful storage: Maximum 720 Hour graphic and tabular trends of all
- parameters, up to 10000 NIBP review, 200 alarm review ,2 Hours of all wave forms
- System software can be upgraded through network
- Data and waveforms color be adjustable
- Arrhythmia analysis and S-T segment analysis
- Suitable for adult, pediatric and neonatal patient
Options:
- Invasive Blood Pressure (IBP)
- Carbon dioxide (CO2) Module
- Thermal Printer
- Touch Screen
Specification:
ECG
Lead Mode 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection I, II, III, avR, avL, avF, V,
Waveform 2 ch
Lead mode 3 Leads ( R, L, F or RA, LA, LL)
Lead selection I, II, III,
Waveform 1 ch
Gain x2.5mm/mV, x5.0mm/mV, x10mm/mV, x20mm/mV, auto
HR and Alarm
Range
Adult 15 ~ 300 bpm
Neo/Ped 15 ~ 350 bpm
Accuracy ± 1% or ± 1bpm,which great
Resolution 1 bpm
Sensitivity > 200 (uV )
Differential Input Impedance > 5 MΩ
CMRR
Monitor > 105 dB
Operation > 105 dB
Diagnosis > 85 dB
Electrode offset potential ±300mV
Leakage Current < 10 uA
Baseline Recovery < 3 S After Defi.
ECG Signal Range ±8 m V ( Vp-p )
Bandwidth
Surgery 1 ~ 15 Hz
Monitor 0.5 ~ 35 Hz
Diagnostic 0.05 ~ 100 Hz
Calibration Signal 1 (mV ), Accuracy :±5%
ST Segment Monitoring Range
Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting
Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY,MISSED BEATS, PNP, PNC
Alarm Available
Review Available
RESPIRATION
Method Impedance between R-F(RA-LL)
Differential Input Impedance >2.5 MΩ
Measuring Impedance Range: 0.3~5.0Ω
Base line Impedance Range: 0 – 2.5 KΩ
Bandwidth 0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range
Adult 0 ~ 120 rpm
Neo/Ped 0 ~ 150 rpm
Resolution 1 rpm
Accuracy ±2 rpm
Apean Alarm 10 ~ 40 S
NIBP
Method Oscillometric
Mode Manual, Auto, STAT
Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
Measuring Period in STAT Mode 5 Min
Pulse Rate Range 40 ~ 240 bpm
Alarm Type SYS, DIA, MEAN
Measuring and alarm range
Adult Mode
SYS 40 ~ 270 mmHg
DIA 10 ~ 215 mmHg
MEAN 20 ~ 235 mmHg
Pediatric Mode
SYS 40 ~ 200 mmHg
DIA 10 ~ 150 mmHg
MEAN 20 ~ 165 mmHg
Neonatal Mode
SYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHg
Resolution
Pressure 1mmHg
Accuracy
Pressure
Maximum Mean error ±5mmHg
Maximum Standard deviation ±8mmHg
Overpressure Protection
Adult Mode 297±3 mmHg
Pediatric Mode 240±3 mmHg
Neonatal Mode 147±3 mmHg
SpO2
Measuring Range 0 ~ 100 %
Alarm Range 0 ~ 100 %
Resolution 1 %
Accuracy 70% ~ 100% ±2 %
0% ~ 69% unspecified
Actualization interval about 1 Sec.
Alarm Delay 10 Sec.
Pulse Rate
Measuring and Alarm Range 0~254bpm
Resolution 1bpm
Accuracy ±2bpm
TEMPERATURE
Channel 1
Measuring and Alarm Range 0 ~ 50 C
Resolution 0.1~C
Accuracy ±0.1~C
Actualization interval about 1 Sec.
Average Time Constant < 10 Sec.
IBP
Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART 0 ~ 300 mmHg
PA -6 ~ 120 mmHg
CVP/RAP/LAP/ICP -10 ~ 40 mmHg
P1/P2 -10 ~ 300 mmHg
Press Sensor
Sensitivity 5 uV/V/mmHg
Impedance 300-3000Ω
Resolution 1 mmHg
Accuracy ±2% or ±1mmHg, which great about 1 Sec.
You must be logged in to post a review.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
Micro Centrifuge Tube 2.0ml
Micro Centrifuge Tube 2.0ml
Micro Centrifuge Tube 2.0ml is one of the best and reliable centrifuge tubes made by Biomed Pakistan. The best thing about the centrifuge tubes are that they are autclaved and packed in different capacities as per the discretion of end-user. Micro Centrifuge Tube 2.0ml gives the best result and quality is 100% guaranteed. For more information regarding Micro Centrifuge Tube 2.0ml in Pakistan please feel free to contact us. Features:- Polypropylene clear polymer facilitates visualization of samples
- Attached snap caps
- Rated to 20,000 x G
- Graduations at every 100 μL for easy volume estimation
- Frosted writing sections in tube surface and tube cover for easy sample identification.
- Temperature range: -80°C to +121°C (Autoclave able)
- Certified free of detectable RNase, DNase & Pyrogen
- Affinity purification or affinity chromatography
- Immunodepletion
- Immunoprecipitation (IP)
- Mechanical failure of the machine
- Lab equipment failure (tubes, etc.)
- Aerosol generation
- Operator Error
- Operating Procedures
- Develop and implement a strict cleaning, storing, and maintenance protocol.
- Only use manufacturer compatible centrifuge, rotor, buckets, caps, and adapters.
- Replace centrifuge parts including bottles, tubes, and O-rings at the first sign of damage.
- Assemble the bottles, buckets, and rotor per the manufacturer’s instructions.
- Tightly seal all tubes and safety cups.
- Close lid during operation.
- Allow to come to complete stop before opening.
- Guideline for Safe Operation
- Use safety cups whenever possible.
- Disinfect or clean weekly and after all spills or breakages.
- Lubricate O-rings and rotor threads weekly.
- Do not operate the centrifuge without the rotor properly balanced.
- Do not use rotors that have been dropped.
- Inspect the speed disk for sign of damage if using an ultra-speed unit and
- discontinue use if damaged. Inspect the rotor and tube cavities for signs of damage and discontinue use if damaged.
- Contact your centrifuge representative for specific information.
- Micro Centrifuge Tube 2.0ml available in Pakistan in 1.0ml, 1.5ml, 2ml
Microplate Reader Rayto RT-6100
Microplate Reader Rayto RT-6100
Microplate Reader Rayto RT-6100 is one the best Microplate Reader in Pakistan, RT-6100 has one of the best quality Elisa Microplates reading. When we talk about the detection of Biological and Chemical data there are a lot of Equipment available in Pakistan and worldwide to get them detected through ELisa's, Enzyme Activities, Nuleic and Protein Quantification. When we talk about the Microplate Reader price in Pakistan, Microplate Reader Rayto RT-6100 is the ultimate choice of Lab Technicians. For more information, questions and queries please feel free to contact us. Features:- PC Controlled System
- 8 Channel optical fiber system enables 5 sec reading for 96 wells plate.
- Calculation Modes includes ABS, Cut-off, Curve, Linear, Log, Exponent, Power and 4PL Regressions.
- Upto 12 different tests can be performed in a single plate.
- Power Laboratory Management Software to store more than 100 Programs, 100,000 results.
- Powerful QC programs including Westguard Rules and instant method, automatic alarm,
- Multiform test reports output.
- Lamp saving and plate shaking feature.
- Save data automatically when power off unexpectedly.
- Compatible with all external printers supported in Windows.
- Powerful Internet Connection enables remote data sharing and OS update.
- Standard Language is English, Multiple Language Software is available on request.
Patient Monitor Accuit Sign 8 MDX-USA
Patient Monitor Accuit Sign 8 MDX-USA
Patient Monitor Accuit Sign 8 MDX-USA is one of the best patient monitor equivalent to any other renowned brand, MDX USA has made it with sophisticated technology which makes Patient Monitor Accuit Sign 8 MDX-USA standing top quality patient monitor. please click here to download the product catalog Accuit Sign™ 8.pdf Feature:- High resolution 12.1"color TFT display
- Suitable for adult, pediatric and neonatal patient
- Color TFT Screen, waveform up to 8 channels
- Operation modes: Diagnostic, Monitor, Surgery
- Light and portable with Built-in rechargeable lithium battery
- UP to 10 kinds of monitor parameters
- Arrhythmia analysis, pace-marker detection and S-T Segment analysis
- 72 hour storage and review of trend grams and tables
- 500 NIBP measurement date can be storage and recall
- Electro surgical unit and defibrillation protected
- Networkable with central monitoring system
- 5-lead or 3-lead selectable
- Input: 5-lead :RA; LA; RL; LL; V or R; L; N; F; C
- ECG waveforms of 7-leads display on the same screen
- Lead selection :I; II; III; avR; avL; avF; Vx
- ECG waveform :2 channels
- Gain selection :12.5mm/s, 25mm/s, 50mm/s
- Accuracy :±1bpm or ±1%, whichever is greater
- Protection :Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation
- Calibration signal :1mV±5%
- Alarm range: Adult :15-300bpm
- Pediatric/Neonatal :15-350bpm
- Arrhythmia analysis and S-T segment analysis
- S-T segment detection Measurement rang :-0.2mv~2.0mv
- Alarm :Yes, audible and visual alarm, alarm events review
- Operation modes :Manual/Automatic/STAT
- Measurement unit :mmHg/KPa selectable
- Measurement types :Systolic, Diastolic and Mean
- Over-pressure protection :YES
- Resolution :1mmHg
- Accuracy :Mean error and standard deviation per ANSI/AAMI SP-10
- Alarm :Systolic, Diastolic, and Mean
- Auto measure time :Adjustable
- Measurement rang :10-270mmHg
- 500 NIBP measurement date can be storage and recall
- Measurement range :0-100%
- Accuracy :70-100%, ±2% 0-69%, upspecified
- Alarm range :0-100% Pulse rate
- Range :20-254bpm
- Accuracy :±3bpm
- Respiration
- Method :RA-LL impedance
- Pediatric/Neonatal :6-150rpm
- Alarm range: Adult :6-120rpm
- Pediatric/Neonatal :6-120rpm
- Apnea alarm :YES
- Channel :Dual-channel
- Alarm range :0-50℃
- Apnea :0.1℃
Patient Monitor Operon OM12
Patient Monitor Operon OM12
Specification:- 12" inched LCD Monitor with high brightness TFT colors
- VGA slot available for attaching high resolution screen such as LED's, Monitors Etc
- SPO2
- Alarm/Beep as per prescribed statistics of the patient
- Accurate Blood Pressure display.
- Heart Beat display
- Printable ECH and other statistics/diagnosis.

Reviews