Touch Screen Patient Monitor MD9015

Touch Screen Patient Monitor MD9015

Touch Screen Patient Monitor MD9015 is a touch screen 15 inch patient monitor by Meditech 192-hour trend graph,1000 group of blood pressure list,ST segment measurements, arrhythmia analysis and more functions, Support up to 32 TCP/IP network connection,composed of a central information system..
Comes with remote control.

Please see our complete range of Patient Monitor & Multiparameter Monitors

Features:

  • 5” high resolution color TFT display with maximum 13 waveforms
  • Full touch-screen enables intuitive operation by clicking on the specific parameters  of the waveform in real time, standard configuration includes the navigation knob
  • Pacemaker detection, electrosurgical interference proof
  • Defibrillation protection and defibrillation synchronization
  • SD Card slot enable memory extension for large data storage
  • USB and serial port enable abundant future upgrades
  • VGA output and Analog output
  • OxyCRG available to judge the respiration and circulation function for neonate
  • Large font display
  • Arrhythmia and S-T segment analysis
  • Built-in rechargeable Li-ion (6hours maximum with 2x 4200mAh batteries)
  • Nurse Call function and bi-directional communication with MFM-CMS central station
  • Multi language: English/Simplified Chinese/Traditional
  • Chinese/Spanish/Czech/Italian/Polish/French/German/Brazilian/Portugese/Russian.
  • Standard configuration: 3/5-lead ECG, NIBP, SpO2, RESP, 2-Temp, PR
  • Optional: 12-lead ECG, Nellcor-SpO2, Omron NIBP, 2-IBP/4-IBP, Mainstream/Side stream CO2,
  • CO, Multi-Gas, Full Touch Screen, Thermal Recorder, WLAN Accessory
  • Large Data Storage: 120 hours graphic and tabular trends of all parameters; 1200 sets of NIBP
  • measurement and 70 alarm events; 2-USB ports and SC card slot ensure data storage/function upgrades.
  • Clinical data can be viewed and managed via Patientcare viewer software (To be released)
  • Clinical network: bi-directional communication with CMS-2000 central station by wired or wireless connection,
  • Complete and flexible mounting solution for ICU and operation room. High-end parameters for more flexible clinical applications.

Options:

  • Invasive Blood Pressure (IBP)
  • Carbon dioxide (CO2) Module
  • Masimo SpO2 Module
  • Thermal Printer

Touch Screen Patient Monitor MD9015

Specification:

Electrocardiogram (ECG)

  • Input mode Five-lead ECG input / three-lead ECG input
  • Lead selection I, II, III, aVR, aVL, aVF, V-
  • Gain selection AUTO,0.25X,0.5X,1X,2X,4X
  • Operating mode Diagnostic mode, monitoring mode, operation mode
  • Calibration signal 1mV ±5%
  • Protection The isolation voltage 4000V, 50/60Hz. Anti-high-frequency interference of electric knife.
  • Anti-defibrillation protection.
  • Pacemaker at the same time use Support
  • Electrode off instructions Each electrode (RL excluded)
  • Scanning speed 12.5mm/s, 25 mm/s, 50 mm/s
  • Common mode rejection ratio ≥90dB
  • Input impedance ≥5.0MΩ

Heartrate (HR)

  • Measuring range Adult 30 ~ 300bpm, newborns 30 to 350 bpm
  • Resolution 1 bpm
  • Accuracy < ±5bpm
  • Heart rate sensitivity ≥0.20mVp-p
  • Alarm range 15 to 350 bpm, upper and lower limits
  • Alarm indication Audible and visual alarm, display the data and parameters flashing display alarm
    message text prompts, there are three levels of alarm

Pulse Oximetry

  • SPO2 Range: 1% to 99%
  • Resolution: 1%
  • Accuracy: 70% to 99% range: ±2%;
  • 1% to 69% range: ±5%;
  • Method: Dual wavelength LED

ST-segment

  • ST-segment measurement range -2.0~+2.0mV
  • ST-segment measurement accuracy Within the range of -0.8 ~ +0.8 mV: ± 0.02mV or reading± 10%,
    Whichever is greater; Other range: undefined
  • Resolution 0.01mV
  • ST-segment update cycle 10s
  • ST segment alarm range -2.0 ~ +2.0 MV, the upper and lower limits continuously adjustable

Arrhythmia analysis

  • Arrhythmia types 13 kinds of (scalable)
  • Respiration Rate
  • Rate: 2 to 120 bpm (CO2)

Resolution: 1 breath/min

NIBP (Non-invasive Blood Pressure)

  • Technique: Oscillometric during inflation
  • Range: Adult/Pediatric: 40 to 240 mmHg
  • Neonate: 10 to 150 mmHg
  • Measurement Cycle: < 40 sec. typical

Automatic Measurement

  • Cycles (Selectable): 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr
  • STAT Mode: 5 minutes of continuous readings
  • Max. Allowable Cuff
  • Pressure: Adult: 300mmHg
  • Pediatric: 240 mmHg;
  • Neonate: 150 mmHg
  • Resolution: 1 mmHg
  • Transducer Accuracy: ±2 mmHg or ±2% of reading,
  • Heart (Pulse) Rate
  • Range: 30 to 250 bpm
  • Accuracy: ±2 bpm or ±3%, whichever is greater

EtCO2 technological index

  • Interface form External interface
    Range of
  • measurement 0~10 kPa or (0~75) mmHg
  • precision(error) (0kPa~5.4kPa) the error is ±0.3kPa、
  • (5.5kPa~10.0kPa)the error is ±0.7kPa
  • Alarm upper limit 2.1~13.2 kPa
  • Alarm lower limit 0~6.5 kPa
  • time 12s
  • EtCO2 exist
  • Unit kPa / mmHg / %
  • Compatibility
  • external main stream and side stream are compatible

IBP technological index

Measured channel Single way and double way are optional
Range of
measurement SYS: 6.7kPa~32.0kPa(50mmHg~240mmHg)
MEAN: 3.4kPa~26.6kPa(26mmHg~200mmHg)
DIA: 2.9kPa~24.0kPa(22mmHg~180mmHg)
Mean error ≤±0.4kPa (±3mmHg)
Range of alarm SYS: upper limit 0.3kPa~53.3kPa(2mmHg~400mmHg)
Lower limit 0kPa~53.1kPa(0mmHg~398mmHg)
MEAN: upper limit 0.3kPa~53.3kPa (2mmHg~400mmHg)
Lower limit 0kPa~53.1kPa (0mmHg~398mmHg)
DIA: upper limit 0.3kPa~53.3kPa ( 2mmHg~400mmHg)
Lower limit 0kPa~53.1kPa ( 0mmHg~398mmHg)
Measured unit mmHg/kPa
Specification of
sensor DPT-248(space)
Consumables mode SCW-UTAH-01

Description

Touch Screen Patient Monitor MD9015

Touch Screen Patient Monitor MD9015 is a touch screen 15 inch patient monitor by Meditech 192-hour trend graph,1000 group of blood pressure list,ST segment measurements, arrhythmia analysis and more functions, Support up to 32 TCP/IP network connection,composed of a central information system..
Comes with remote control.

Please see our complete range of Patient Monitor & Multiparameter Monitors

Features:

  • 5” high resolution color TFT display with maximum 13 waveforms
  • Full touch-screen enables intuitive operation by clicking on the specific parameters  of the waveform in real time, standard configuration includes the navigation knob
  • Pacemaker detection, electrosurgical interference proof
  • Defibrillation protection and defibrillation synchronization
  • SD Card slot enable memory extension for large data storage
  • USB and serial port enable abundant future upgrades
  • VGA output and Analog output
  • OxyCRG available to judge the respiration and circulation function for neonate
  • Large font display
  • Arrhythmia and S-T segment analysis
  • Built-in rechargeable Li-ion (6hours maximum with 2x 4200mAh batteries)
  • Nurse Call function and bi-directional communication with MFM-CMS central station
  • Multi language: English/Simplified Chinese/Traditional
  • Chinese/Spanish/Czech/Italian/Polish/French/German/Brazilian/Portugese/Russian.
  • Standard configuration: 3/5-lead ECG, NIBP, SpO2, RESP, 2-Temp, PR
  • Optional: 12-lead ECG, Nellcor-SpO2, Omron NIBP, 2-IBP/4-IBP, Mainstream/Side stream CO2,
  • CO, Multi-Gas, Full Touch Screen, Thermal Recorder, WLAN Accessory
  • Large Data Storage: 120 hours graphic and tabular trends of all parameters; 1200 sets of NIBP
  • measurement and 70 alarm events; 2-USB ports and SC card slot ensure data storage/function upgrades.
  • Clinical data can be viewed and managed via Patientcare viewer software (To be released)
  • Clinical network: bi-directional communication with CMS-2000 central station by wired or wireless connection,
  • Complete and flexible mounting solution for ICU and operation room. High-end parameters for more flexible clinical applications.

Options:

  • Invasive Blood Pressure (IBP)
  • Carbon dioxide (CO2) Module
  • Masimo SpO2 Module
  • Thermal Printer

Touch Screen Patient Monitor MD9015

Specification:

Electrocardiogram (ECG)

  • Input mode Five-lead ECG input / three-lead ECG input
  • Lead selection I, II, III, aVR, aVL, aVF, V-
  • Gain selection AUTO,0.25X,0.5X,1X,2X,4X
  • Operating mode Diagnostic mode, monitoring mode, operation mode
  • Calibration signal 1mV ±5%
  • Protection The isolation voltage 4000V, 50/60Hz. Anti-high-frequency interference of electric knife.
  • Anti-defibrillation protection.
  • Pacemaker at the same time use Support
  • Electrode off instructions Each electrode (RL excluded)
  • Scanning speed 12.5mm/s, 25 mm/s, 50 mm/s
  • Common mode rejection ratio ≥90dB
  • Input impedance ≥5.0MΩ

Heartrate (HR)

  • Measuring range Adult 30 ~ 300bpm, newborns 30 to 350 bpm
  • Resolution 1 bpm
  • Accuracy < ±5bpm
  • Heart rate sensitivity ≥0.20mVp-p
  • Alarm range 15 to 350 bpm, upper and lower limits
  • Alarm indication Audible and visual alarm, display the data and parameters flashing display alarm
    message text prompts, there are three levels of alarm

Pulse Oximetry

  • SPO2 Range: 1% to 99%
  • Resolution: 1%
  • Accuracy: 70% to 99% range: ±2%;
  • 1% to 69% range: ±5%;
  • Method: Dual wavelength LED

ST-segment

  • ST-segment measurement range -2.0~+2.0mV
  • ST-segment measurement accuracy Within the range of -0.8 ~ +0.8 mV: ± 0.02mV or reading± 10%,
    Whichever is greater; Other range: undefined
  • Resolution 0.01mV
  • ST-segment update cycle 10s
  • ST segment alarm range -2.0 ~ +2.0 MV, the upper and lower limits continuously adjustable

Arrhythmia analysis

  • Arrhythmia types 13 kinds of (scalable)
  • Respiration Rate
  • Rate: 2 to 120 bpm (CO2)

Resolution: 1 breath/min

NIBP (Non-invasive Blood Pressure)

  • Technique: Oscillometric during inflation
  • Range: Adult/Pediatric: 40 to 240 mmHg
  • Neonate: 10 to 150 mmHg
  • Measurement Cycle: < 40 sec. typical

Automatic Measurement

  • Cycles (Selectable): 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr
  • STAT Mode: 5 minutes of continuous readings
  • Max. Allowable Cuff
  • Pressure: Adult: 300mmHg
  • Pediatric: 240 mmHg;
  • Neonate: 150 mmHg
  • Resolution: 1 mmHg
  • Transducer Accuracy: ±2 mmHg or ±2% of reading,
  • Heart (Pulse) Rate
  • Range: 30 to 250 bpm
  • Accuracy: ±2 bpm or ±3%, whichever is greater

EtCO2 technological index

  • Interface form External interface
    Range of
  • measurement 0~10 kPa or (0~75) mmHg
  • precision(error) (0kPa~5.4kPa) the error is ±0.3kPa、
  • (5.5kPa~10.0kPa)the error is ±0.7kPa
  • Alarm upper limit 2.1~13.2 kPa
  • Alarm lower limit 0~6.5 kPa
  • time 12s
  • EtCO2 exist
  • Unit kPa / mmHg / %
  • Compatibility
  • external main stream and side stream are compatible

IBP technological index

Measured channel Single way and double way are optional
Range of
measurement SYS: 6.7kPa~32.0kPa(50mmHg~240mmHg)
MEAN: 3.4kPa~26.6kPa(26mmHg~200mmHg)
DIA: 2.9kPa~24.0kPa(22mmHg~180mmHg)
Mean error ≤±0.4kPa (±3mmHg)
Range of alarm SYS: upper limit 0.3kPa~53.3kPa(2mmHg~400mmHg)
Lower limit 0kPa~53.1kPa(0mmHg~398mmHg)
MEAN: upper limit 0.3kPa~53.3kPa (2mmHg~400mmHg)
Lower limit 0kPa~53.1kPa (0mmHg~398mmHg)
DIA: upper limit 0.3kPa~53.3kPa ( 2mmHg~400mmHg)
Lower limit 0kPa~53.1kPa ( 0mmHg~398mmHg)
Measured unit mmHg/kPa
Specification of
sensor DPT-248(space)
Consumables mode SCW-UTAH-01