Multiparameter Monitor MD905 Meditech

Multiparameter Monitor MD905 Meditech

Multiparameter Monitor MD905 Meditech Touch screen,5.0 inch color TFT Screen,simple for operating, quickly & accurately measure the data; Build-in rechargeable Li-battery, up to 15 hours running time, Support AC and DC power; Adjustable audible and visual alarms, and sensor off alarm.

Features:

  • Portable,compact, easy for carrying and operation
  • Clear and bright colour 5.0 Inch TFT-LCD with touch screen and real time display
  • Intelligent Measuring of ECG.NIBP.SpO2.PR.PLETH.TEMP
  • Storage/Review trend data up to 129.6 hours and 3888 groups
  • Storage ECG waveform,each section is 8 seconds, totally is 30 sections; NIBP,SPO2,pulse rate and TEMP data sheet review up to 100 groups; which can be printed via connecting BlueTooth printer
  • Utility PC software package for long time monitoring,history data uploading/review/printing/storage.
  • Uploading history data to PC for reviewing, storage or printing via connecting USB data line or BlueTooth wireless
  • Audio and visual alarm Built-in rechargeable Li-ion battery, up to 15-hour power supply Back light can be adjusted freely
  • To fulfill Communication function, please install the data viewer software in a PC equipped with a printer, and connect the monitor with the PC by an USB cable or BlueTooth wireless.
Specification: ECG Input:3 /5Lead ECG cable standard AAMI cable connector Lead Selection:I, II, III Gain Selection:×1, ×2, ×4, ×8 Sweep Speed: 12.5 25 and 50 mm/s Frequency Response: None filter: 0.05~100Hz (-3dB) filter: 0.5~40Hz (-3dB) Calibration Signal: 1mV square wave Protection: Against electrosurgical interference and defibrillation Heart Rate Measuring Range: 20 bpm~300 bpm Renew Time: 1 time per beat Accuracy: ±1 bpm Alarm Mode: Audible and visual alarm SpO2 SpO2% Measuring Range:0%~100% Resolution:1 % Accuracy:±2 %(90%~99%) ±3 %(70%~89%)unspecified (0%~69%) Pulse Rate Measuring and Alarm Range:20~300bpm Resolution: 1bpm Accuracy: ±1bpm NIBP Method: Oscillometric Mode: Manual Auto STAT Measuring Interval in AUTO Mode: 1 2 3 5 10 15 20 30 45 60 (min) Measuring Period in STAT Mode: 5 min Cuff Pressure Range:0 mmHg~300mmHg Pulse Rate Range: 30 bpm~250bpm Measurement Rage: Adult 30 mmHg~255mmHg Pediatric 30 mmHg~160mmHg Over-pressure Protection: Adult 300mmHg Pediatric 220mmHg Pressure Resolution : 1mmHg The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those measured by trained medical personnel using cuff and stethoscope. The MEAN value measured using this device is equal to that measured using blood pressure measurement device. Temperature Input: Body surface thermal-sensitive resistor temperature sensor Measuring Range: 0℃~50℃ Accuracy: ±0.1℃ Storage and Review Maximum Data Quantity: 3888 groups Maximum Trend Time: Continuous 129.6 hours Power: Rechargeable battery 1700mAh~2000mAh.7.2V. Charge(discharge) ≧1000times. Charge time: 2hours Work Operation/relative humidity:0~55℃/10~80%RH Storage Operation/relative humidity:–20~60℃/10~90%RH Power Supply AC Power Adaptor Input: 100~240VAC 50/60Hz 0.7A Output: DC 5V 1.5A Battery Li-ion rechargeable battery 3.7V/7200mAH Operating Time: 15 hours with full battery capacity. (Condition: 25℃ NIBP working period is 15 minutes) Recharge Time: 10 hours. Environment Temperature Working:0℃~45℃ Transport and Storage: -25℃~85℃ Humidity Working:30% ~85 % Transport and Storage: 30% ~95 % (no condensation) Display Specification Measurement Display: color TFT- LCD/touch screen Power Supply Indicator: Dual-color LED (red/green) Charging indicator: A green LED Size: 209mm×104mm×47.5mm Net Weight: 655g Monitoring Parameter Printer (optional) Type: Thermal micro-printer Printer Paper: 58 mm thermal paper Paper roll diameter 33mm Interface: Bluetooth wireless interface Recording Types: Real-time printing and review data printing

Multiparameter Patient Monitor MD9000s Meditech

Multiparameter Patient Monitor MD9000s Meditech

Multiparameter Patient Monitor MD9000s Meditech patient monitor has a 12.1"color TFT screen. Monitoring ECG, SP02, NIBP, RESP .2-TEMP. PR as standard parameters, and 2-IBP, ETC02 and thermal printer as optional. MD9000s is one of its kind and the best selling patient monitor in Europe.

Features:

  • 12.1'' TFT color LCD, multi-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakh, Polish, Czech).
  • Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
  • All-round monitor for adult, pediatric and neonate.
  • With standard interface, oxygen graph, trend graph, big character interface and view bed, convenient to observe. Finish all operations by keys and knobs.
  • Maximum 8-channel waveform synchronous display.
  • Display 7-lead ECG waveform on one screen, cascade ECG waveform display
  • Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
  • Heart rate variability (HRV) analysis function
  • NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.
  • Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
  • Drug concentration calculation and titration table functions.
  • One-touch printing of trend graph
  • Connect to Central Monitoring System by 3G, Wi-Fi or wired mode.
  • AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
  • Anti-high frequency surgical unit, defibrillation-proof (special leads are necessary).
Options:
  • Invasive Blood Pressure (IBP)
  • Carbon dioxide (CO2) Module
  • Masimo SpO2 Module
  • Thermal Printer
Specification: ECG Lead Mode 5 Leads ( R, L, F, N, C or RA, LA, LL, RL, V) Lead selection I, II, III, avR, avL, avF, V, Waveform 2 ch Lead mode 3 Leads ( R, L, F or RA, LA, LL) Lead selection I, II, III, Waveform 1 ch Gain ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV HR and Alarm Range Adult 30 ~ 300 bpm Neo/Ped 30 ~ 350 bpm Accuracy ±1% or ±1bpm, which great Resolution 1 bpm Sensitivity > 200 uV P-P Differential Input Impedance > 5 MΩ CMRR Monitor > 105 dB Operation > 105 dB Diagnosis > 85 dB Electrode offset potential ±300mV Leakage Current < 10 uA Baseline Recovery < 10 s After Defi. ECG Signal Range ±8 mV (Vp-p) Bandwidth Surgery 1 ~ 15 Hz Monitor 0.5 ~ 35 Hz Diagnostic 0.05 ~ 100 Hz Calibration Signal 1 mV (Vp-p), ±5% Accuracy ST Segment Monitoring Range Measure and Alarm -2.0 ~ +2.0 mV ARR Detecting Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Alarm Available Review Available Tall T-wave rejection capability 1.2mV Heart rate averaging the average value of the latest 6 R-R intervals which have ignored the maximum and minimum Updating rate of the display 1s Heart rate meter accuracy and response to irregular rhythm: Bigeminy ventricular 80bpm Bigeminy ventricular alternative lente 57 or 63bpm Bigeminy ventricular alternative rapid 122 or 123bpm Systoles bidirectional 95bpm Response time to heart rate meter to change in heart rate 80 to 120bpm Average 3.7s Range 3.2s ~ 4.1s 80 to 40bpm Average 4.7s NIBP Method Oscillometric Mode Manual, Auto, STAT Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120,240,480,960Min Measuring Period in STAT Mode 5 Min Pulse Rate Range 40 ~ 240 bpm Alarm Type SYS, DIA, MEAN Measuring and alarm Range Adult Mode SYS 40 ~ 270 mmHg DIA 10 ~ 215 mmHg MEAN 20 ~ 235 mmHg Pediatric Mode SYS 40 ~ 200 mmHg DIA 10 ~ 150 mmHg MEAN 20 ~ 165 mmHg Neonatal Mode SYS 40 ~ 135 mmHg DIA 10 ~ 100 mmHg MEAN 20 ~ 110 mmHg Resolution Pressure 1mmHg Accuracy Pressure Maximum Mean error ±5mmHg Maximum Standard deviation ±8mmHg Overpressure Protection Adult Mode 297±3 mmHg Pediatric Mode 240±3 mmHg Neonatal Mode 147±3 mmHg TEMPERATURE Channel 2 Measuring and Alarm Range 0 ~ 50 °C Resolution 0.1°C Accuracy ±0.1°C Actualization interval about 1 Sec. Average Time Constant < 10 Sec. IBP (optional) Channel 2 Label ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measuring and alarm range ART 0~300mmHg PA -6~120mmHg CVP/RAP/LAP/ICP -10~40mmHg P1~P2 -10~300mmHg Press Sensor Sensitivity 5 uV/V/mmHg Impedance 300-3000Ω Resolution 1mmHg Accuracy ±2% or 1mmHg which great Actualization Interval about 1 Sec Display Device 12.1 in. Color TFT Made by Sharp Japan Messages 7 Waveforms Maximum 1 Alarm LED ( Yellow/Red) Screenshot 1 Power LED (Green) 1 Battery Charge LED ( Yellow) 3 Sound Mode corresponding Alarm Mode Signal Interface ECG Output BNC Amplitude 1 V/mV Accuracy < 5 % Impedance 50 Ω Signal Delay < 20 mS Recall Trend Recall Short 1 hrs, 1 Second Resolution Long 72 hrs, 1 Min. Resolution Alarm Event Recall 71 alarm events of all parameters and 8/16/32seconds of corresponding waveform. NIBP Measurement Recall At least 400 NIBP measurement data. Battery Rechargeable 3.7 A/Hr 7.4V Li battery Operating time under the normal use and full charge greater than 180minutes Operating time after the first alarm of low battery will be about 5 minutes Recorder (Option) Record Width 48 mm Paper Speed 25/50 mm/S Trace 2 Size and Weight Size Monitor 310 x 140 x 263 mm Weight Monitor 3.8 kg