Medical Equipment's
Defibrillator Rescue life
Defibrillator Rescue life
Defibrillator Rescue life is Designed to be the ideal device to deal with cardiovascular emergencies and to monitor the patient in hospital and non-hospital environments. Thanks to its compact and shockproof design. RESCUE LIFE is the best ally for hard times. When time becomes an enemy, thanks to its intuitive navigation interface RESCUE LIFE lets the user initiate its functions in a fast and easy way. Developed with the purpose to satisfy the most elevated demands, RESCUE LIFE guarantees a complete monitoring of the patient in a critical situation: blood pressure, saturation and 12-leads ECG allow the user to have a clear picture of the clinical situation. With its state-of-the-art biphasic technology, RESCUE LIFE guarantees the maximum effectiveness in the shortest time. RESCUE LIFE means versatility. TECHNICAL SPECIFICATIONS GENERAL SPECIFICATIONS Dimension • 369 x 240 x 340 mm Weight • 5,5 Kg with battery Electrical •• AC 100-240 VAC, 50/60 Hz- inverter12V car adapter (optional) Rechargeable 14.4 V - 2 Ah NiMh battery Capacity • 100 shocks at 230J with battery fully charged Software • Voice and texts multilanguage Memory • Internal flash 4 Gb up to 300 hrs of ECG data, events and usage review ENVIRONMENTAL Temperature ••• Operational -5° ~ 55° C Storage -20° ~ 70° C Relative humidity 10 ~ 95% Isolation • ECG type CF, Defibrillation type BF Water proof • Class IPX4 DEFIBRILLATION Waveform •• Bipashic Truncated Exponential (BTE) HiCAP technology (Large storage capacitor) Impedance • Compensated, range 25 - 200 Ohm Charge time • 6 sec for 230 J with battery fully charged AED MODE (OPTIONAL) Energy • Fixed energy at 200 J Protocol • AHA 2010 CPR Guidelines with voice and text prompts Shockable rhythms • VF with amplitude > 100 μV and VT with rhythm >150 bpm Sensitivity •• Shockable rhythm-VF > 95% Shockable rhythm-VT > 75% Specificity ••• According to AHA 2010 Normal sinusoidal rhythm > 99% Asystole and other non-shockable rhythms > 95% MANUAL MODE Energy range • 1 - 230 J (from 1-10 J in 1 J steps; from 10 to 230 J in 10 J steps) Commands • Multifunction trim knob. Charge and shock button directly in the front panel for hands free defibrillation Paddles •• Reusable adult & pediatric defi paddles with charge/shock command Disposable defi pads and internal defi paddles (optional) Operating mode • ECG « R » wave synchro or asynchro mode Indicators •• Battery and main led indicators Clear and visible backlight color buttons DISPLAY Type • High contrast TFT color LCD 5.7” (320 x 240 pixels) Information • Operational information, ECG traces, Spo2 value, NIBP values, parameters, Heart Rate indicator, filters, alarms and battery status ECG MONITORING Bandwidth • 0.5 - 120 Hz (-3 db) with filters off CMRR • > 90 db Input impedance • > 20 Mohm Input •• Patient cable 5 leads (I,II,III,aVL,aVR,aVF) - standard Patient cable 10 leads (12 channels ECG) - optional Gain • 5, 10, 20 mm/mV with patient cable. AUTO with pads Velocity • 5, 10, 25, 50 mm/sec Filters • 50/60 Hz, EMG Filter, base line HR range • 20 - 300 bpm (~ 2%), digital readout on the display Alarm • HR max settable 250 bpm; HR min 20 bpm SPO2 (OPTIONAL) SpO2 range • 0 - 100% HR range • 18 - 300 ppm Accuracy • 70 - 100% ~ 2% for adults with finger clip sensor Alarm • Adjustable min 65% PRINTER Type • Integrated thermal printer for ECG traces and events documentation hardcopy including HR/SpO2/NIBP values Paper speed • 5, 10, 25, 50 mm/sec Paper width • 58 mm Operating model • Manual, automatic (10” pre and post shock recording) EXTERNAL PACEMAKER (OPTIONAL) Type • Rettangular wave Operating mode • Fixed on demand Pulse rate • 30 ppm to 250 ppm, adjustable in steps of 5 ppm Impulse duration • 22 ms Pulse current • 0 to 150 mA adjustable in steps of 5mA Amplitude • Max 150 V STANDARDS & SAFETY Standard • IEC 60601-2-4; IEC 60601-1; IEC 60601-1-2, Class II, type BF CE Mark EEC 93/42 • Medical device, class IIb Specifications and contents of this document subject to change without notice.Self Aligning Ball Bearing 1200 ETN9 SKF
Self Aligning Ball Bearing 1200 ETN9 SKF
Self Aligning Ball Bearing 1200 ETN9 SKF with polyamide cage 10mm inside x 30mm outside x 9mm wide, also known as 1200ETN9, 1200TV, 1200TVH, 1200TN. The self-aligning ball bearing was invented by SKF. It has two rows of balls and a common sphered raceway in the outer ring. The bearing is consequently self-aligning and insensitive to angular misalignments of the shaft relative to the housing. The design of self-aligning ball bearings is such that angular misalignment between the outer and the inner rings can be accommodated without any negative effect on bearing performance. Size: 10 x 30 x 9mm Principal dimensions d: 10mm D: 30mm B: 9mm Basic load ratings Dynamic: 5,53kn Static: 1,18kn Fatigue load limit 0.061kn Speed ratings Reference speed: 56000 r/min Limiting speed: 36000 r/min Mass: 0.034kg Dimensions d2: 16,7mm D1: 24,4mm R1,2 min: 0,6mmLIFELINE PRO AED Defibrillator
LIFELINE PRO AED Defibrillator
LIFELINE PRO AED Defibrillator Meet the AED that’s taking easy-to-use to a whole new level. The Lifeline VIEW family of defibrillators are the first and only AEDs with video in full-motion color. The Lifeline PRO offers professional responder's full manual capabilities. With award-winning design, durability, and easy maintenance, backed by the Defibtech commitment to innovation and excellence. We can guarantee you’ve never seen an AED like this before. CLICK TO DOWNLOAD THE CATALOG LIFELINE AED PRO.pdf CLICK TO SEE OUR FULL RANGE OF AUTOMATED EXTERNAL DEFIBRILLATORS & DEFIBRILLATORSFeatures:
- Introducing Lifeline PRO
- Advanced technology
- Professional capabilities
- Award-winning design
- Robust and durable
- Fully featured
- Easy-to-use and maintain
- Fully configurable
Suction Machine Apparatus YB-DX23B
Suction Machine Apparatus YB-DX23B
Suction Machine Apparatus YB-DX23B is one the best suction unit used by many health professionals worldwide, it is not only useful in premise but as well as in the ambulances. Suction Machine Apparatus YB-DX23B is widely used in Pakistan and the results and over all feedback from the operators are more than satisfactory. When we talk about Suction Machine or Suction Machine Price in Pakistan the first name comes into mind is Suction Machine Apparatus YB-DX23B. Brand: Smaf, China Model: YB-DX23B please click here to download the catalog Suction Machine Apparatus YB-DX23B.pdfAmbulance Loading Stretcher PM100
Ambulance Loading Stretcher PM100
Ambulance Loading Stretcher PM100 has high quality aluminum alloy materials and aluminum alloy die casting parts. the Sponge Cushion is used to lie down with comfortably. Legs folding mechanism, controlled by left and right handles. Only one ambulance officer needs to push the patient into the ambulance. The fixed bracket is fixed to the ambulance and the stretcher can be easily locked after getting on the car through sideways. For Ambulance Manufacturing and modifications please click the link to see our full range of our LIFEMED AMBULANCES Features:- High Strength aluminum alloy
- Easily gets to the ambulance
- Comfortable sponge cushion
- Controllable mechanical folding leg
- Height Position LxWxH 190x55x92cm
- Lower Position LxWxH 190x55x92cm
- Maximum Angle of the Bach 75 degrees
- Packing Size: 195x62x26cm
- Load Bearing: 159 Kg approximately
- Net Weight: 40 Kg
- Gross Weight: 46 Kg
Defibrillator Defi Xpress Meditech
Defibrillator Defi Xpress Meditech
Defibrillator Defi Xpress Meditech is defibrillator device with voice alarm which can meet your clinical needs from Basic Life Support (BLS) to Advanced Cardiac Life Support (ACLS). Defibrillators benefit patients who experience a sudden case of heartbeat is arrhythmias. In these instances Defibrillators are an important tool for anyone in the vicinity of a victim suffering from ventricular arrhythmia as well. arrhythmia renders the patient unconscious. the heart may beat too fast, too slow or an irregular mix of both. The anticipated outcome of sucharrhythmias is either cardiac arrest or a stroke.Product Features:
Display Screen Type: High-resolution display Screen Size: 7 inches (17.7 cm) diagonally Sweep Speed: 25mm/sec Information: Heart Rate . Lead/Pads. Alarm . On/Off . SpO2 . AED Functions and Prompts Alarm Selection and Limits Delivered Energy. 5 Languages available: English.Russian.Spanesh.Chinese.Turkish Defibrillator Waveform: Biphasic Charge Time: Less than 7 seconds with a new fully charged battery. Energy Display: Monitor display indicates both selected and delivered energy. Charge Prompt Type: Voice and visual prompts. Electrode Impedance Measurement Range: 0-250 ohms. ECG Monitoring Patient Connection: 3-lead ECG cable or 5-lead ECG cable paddles. Lead Selection: Displayed on monitor paddles I II III AVR AVL AVF V. ECG Size: 0.25 0.5 1 1.5 2 4 cm/mV display on monitor. Heart Rate: 20-300BPM. Heart Rate Alarm: On/Off displayed on monitor user-selectable. Smart Alarms: Beeper/voice prompts indicate shock able rhythm. Battery Type: Rechargeable Ni-MH battery 12V. Operating time: For a new fully charged battery: 60 defibrillator discharges at maximum energy or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions. SpO2 Module (Options): Measurement Range: 30~100% ±2% between 80%~90% others ±5% Alarm Range: User set high limit and low limit. Alarm Accuracy: ±10% within setting values. Alarm time Accuracy: less than 12 sec. 1-Meditech Pulse Oximeter 2-Nellcor Pulse Oximeter Recorder Paper: 50mm thermal. Speed: 12.5mm/sec 25mm/sec 50mm/sec. User-selectable 6-second delay. Printing Method: High-resolution thermal print head. Print-out Modes: Manual or automatic user-configurable. On/Off Control: Front panel and paddle. Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge. AED Mode AED Function: Auto analyze and charge x3 with programmable auto energy level selection screen prompts and voice prompts. Shockable Rhythms: Ventricular fibrillation with amplitude >=200uV ventricular tachycardia with rates >=140bpm and QRS complex wave duration >=140ms. Charge Control: Control on device front panel press key on paddle. Prompts: Voice and visual prompts. Manual Mode Energy Selection: Selectable at 2 5 7 10 20 30 50 70 100 150 200 300 360 joules. Synchronized Mode: Synchronizes defibrillator pulse to patient's R-wave. "SYNC" message displayed on monitor.Technical Specification:
The Specification of physical electronic isolation defibrillator battery electromagnetic compatibility and rhythm recognition performance will be described in this section: Data Acquisition and Analysis The DEFI XPRESS is no longer automatically configured to a certain frequency response. There are two diagnostic frequency options: 0.05-150 Hz Diagnostic Frequency Filter and 0.05-40 Hz Filtered Diagnostic Frequency filter. See chapters 7 on switching between these two options. Defibrillator Waveform Details: The tables below provide details of the waveforms delivered by the DEFI XPRESS when connected to resistive loads of 25 50 and 100 Ohms and set to its maximum output. The waveforms are characterized by DEFI XPRESS values for peak current (Ip) for biphasic: duration of The first output phase (tphase1) and duration of the second output phase (tphase2). The values shown are within 10%. Waveform: Truncated Exponential Biphasic Output Energy Accuracy: +/- 10% or 1J (whichever is greater) at 50 ohms +/- 15% or 1J (whichever is greater) at 25 to 100 ohms Energy Select: External: 2 5 7 10 20 30 50 70 100 150 200 300 360 J. Charge Time: < 12 seconds @ 360 J (with a Ni-MH 12 volt - MEDITECH battery after15discharges). < 15 seconds @ 360 J (no battery 90% AC mains voltage) Charge Indicator: Audible and graphic. Output : Adult paddles pediatric adapter and multipurpose hands-free adapter available. Synchronizer: Delivers energy within 60 msec. Disarm: Front panel switch. Monitor/Display Input: 3-lead 5-lead patient cable Size: 7 inches (16.5 cm) diagonal non-fade. Type: color (TFT) Display Resolution: 800 x 600 pixels. Sweep Speed: 12.5mm/s25mm/s50mm/s Lead Selections: I II III AVR AVL AVF V. Frequency Response: (User-selectable). 0.7 to 20 Hz operation mode 0.3 to 40 Hz Monitoring mode 0.05 to 150 Hz Analysis mode 0.5 to 30 Hz AED mode Common Mode Rejection:>=60dB Heart Rate Meter: 20 to 300 BPM. Heart Rate Alarms: User-selectable. Size: 0.125 0.25 0.5 1 2 4 cm/mv and auto-ranging. ECG Output: 1 V/mV. Heart Rate Response to Irregular Rhythm: (AAMI EC13-1992 section 4.1.2.1.e.) Alarms Heart Rate Spo2 Alarm: Audible: 5 pulse 800 tone with a PW of 150 msec a PRI of 225 msec and a repetition interval of 10 seconds. Visual: Heart Rate Alarm causes the displayed heart rate to flash at 2 Hz. This display is located at the top of the display and is 0.4" high and 0.28 to 0.840" wide depending on num-ber of digits in the heart rate. Is amber black white or whatever the color the display text is. Lead Fault Alarm: Audible: 3 pulse 500 Hz triplet tone with a PW of 200 msec a PRI of 310 msec. When the HR alarm is set or the pacer is on the lead fault tone repeats at a repetition interval of 20 seconds. Visual: Lead Fault condition causes a "LEAD FAULT" message to be displayed on the trace along with a dashed line the width of the trace. The text is 0.18" high and is the color of the display text. The dashed line is 5" Long the width of the display. The signal is not modulated. Physiological Alarms (Spo2): Audible: See Heart Rate Alarm Visual: Physiological alarms cause the displayed parameter to flash at 2 Hz. Color is amber white or the same as the display colored text. Mute Duration: 90 seconds. Recorder Type: High-resolution thermal array. Annotation: Time date ECG lead ECG gain heart rate defibrillation and treatment summary ACLS events. Paper Width: 50 mm. Paper Speed: 25 mm/sec 50 mm/sec 12 Lead 50 mm/sec Delay: 6 seconds. Frequency Response: Automatically set to monitor's frequency response. Battery High Capacity Type: Ni-MH 12V volt - MEDITECH Up to 4 hours ECG monitoring or 110 full-energy dis-charges or 3 hours combined ECG Spo2 and monitor-ing Proper battery care is required to maintain maximum avail-able capacity. Low Battery Indicator: Flashing low battery icon on display and flashing LED on front panel.. Recharge Rate: 80% in 7.5 hours. 100% in 9 hours. General Weight: 10 pounds (4.95 kg) (basic configuration). Size: 13 x 12.5 x 5.3 inches (33 x 31.8 x 13.5 cm). Operating: Temperature*: 0 to 45° C Humidity* (NC): 15 to 95% RH (30 to 90% with CO2 probe) Vibration*: MIL-STD 810E Shock / Drop*: MIL-STD 810E Altitude: Up to 4572 M (15000 feet) Transport and Storage: Temperature: -30 to 70°C (-20 to 70°C with CO2 probe) Humidity: 15 to 95% RH (non-condensing) Atmospheric pressure: 860 to 1060 hPa Shock/vibration: ISTA 1A Enclosure Protection*: Solid Foreign object: IEC 529 IP2X Water: IEC 529 IPX4. All tests performed per AAMI DF-2 Defibrillation Standard. Operating Power: Ni-MH 12 volt - MEDITECH SAED Rhythm Recognition Performance The DEFI XPRESS SAED algorithm exceeds the requirements of ANSI/AAMIDesigning and Planning of Operation theaters
Designing and Planning of Operation Theaters (OT) complex is one of the most critical aspects of hospital architecture. A well-planned OT is not merely a room for surgery; it is a highly engineered environment designed to maximize clinical efficiency, ensure absolute sterility, and provide a safe workspace for medical professionals.
1. Zoning and Traffic Flow
Effective OT planning begins with the concept of zoning. To prevent cross-contamination, the complex must be divided into four distinct zones:
- Protective Zone: Entrance and changing rooms.
- Clean Zone: Recovery rooms and pre-operative holding.
- Aseptic Zone: The actual sterile operating rooms and scrub stations.
- Disposable Zone: Areas for dirty linen and waste removal.
FEATURED PRODUCTS
ELECTRONICS
Eames lounge chair
Classic wooden chair
Decoration wooden present
Nam gravida vulputate est venenatis eu at ullamcorper consectetur parturient suspendisse a elit lobortis ut convallis vestibulum vulputate nunc praesent mattis sem faucibus risus sociosqu.Dapibus curae a ac vestibulum a magnis ullamcorper orci a iaculis adipiscing augue a massa a torquent feugiat a. Scelerisque vestibulum.
Wine bottle lantern
iPhone dock
Augue adipiscing euismod
INNOVATIVE GADGETS
Exploring Atlanta’s modern homes
Vivamus enim sagittis aptent hac mi dui a per aptent suspendisse cras odio bibendum augue rhoncus laoreet dui praesent sodales sod...
Green interior design inspiration
A sed a risusat luctus esta anibh rhoncus hendrerit blandit nam rutrum sitmiad hac. Cras a vestibulum a varius adipiscing ut digni...
Collar brings back coffee brewing ritual
Adipiscing hac imperdiet id blandit varius scelerisque at sagittis libero dui dis volutpat vehicula mus sed ut. Lacinia dui rutrum...
Reinterprets the classic bookshelf
Aliquet parturient scele risque scele risque nibh pretium parturient suspendisse platea sapien torquent feugiat parturient hac ame...
Creative water features and exterior
Ac haca ullamcorper donec ante habi tasse donec imperdiet eturpis varius per a augue magna hac. Nec hac et vestibulum duis a tinci...