12 Channel ECG Machine – CardioCare2000 – Bionet USA
12 Channel ECG Machine – CardioCare2000 – Bionet USA
12 Channel ECG Machine – CardioCare2000 – Bionet USA is one of the best 12 Channel ECG Machine the product is manufactured in Korea, it is also pertinent to notice that Bionet is USA based company. 12 channel cardiocare2000 is the most used product all over the world.
Please click CardioCare2000_ECG_EKG_Brochure.pdf to download the Full catalog. For more information, questions, queries and quotations please feel free to contact us.
Product Description:
- Convenient A4 size print-outs allow for easy chart filing
- Copy function allows varied printouts from single patient sample
- Grid function allows you to use low cost plain fax paper
- One-touch operation (monitoring, recording mode)
- Accurate simultaneous 12 channel cardiac data acquisition
- Over 130 kinds of interpretation results based on advanced Minnesota code
- High-Quality 12ch interpretive ECG at a 3ch price
- Free S/W upgrade via internet
SPECIFICATION:
ECG leads 12 lead, simultaneous ECG and acquisition
Dimension 296(W) × 305.5(H) × 92.5(D)㎜, Approx.2.98㎏
Recording channel 3,6,12 channel and 1 channel(60 sec)
Sensitivity 5, 10, 20, auto(I~aVF: 10, V1~V6: 5) ㎜/㎷
Printing speed 12.5, 25, 50 ㎜/s
Sampling rate 500 samples/sec
Filters AC(50/60㎐, -20㏈ or better)
Muscle(25 ~ 35㎐, -3㏈ or better)
Base line drift (0.1㎐, -3㏈ or better)
Low pass filter (off, 40㎐, 100㎐, 150㎐)
Display 2×16 character LCD Display
LCD display Sensitivity, speed, filter status, HR, printing form, rhythm lead
LED indicator signal quality, power source, battery.
Keyboard Membrane keyboard, Alphanumeric and symbol available
Patient data ID, name, age, sex, height, weight
Basic measurement Heart rate, PR int, QRS dur, QT/QTc, P-R-T axis
Recorder Thermal print head, Thermal roll paper
Report papers : width : A4 : 210㎜ or 8.5″
length : A4 : 300㎜ or 11″
Effective writing width : 204 ㎜
Resolution : Vertical : 8 dots/㎜
Horizontal : 16dots/㎜
Electrical Internal noise : 20㎶(p-p)max
Input circuit : Floating input
Isolated and defibrillation protected
Input impedance : ≥10MΩ
Input voltage range : ≥±5㎷
Common Mode Rejection : ≥+100㏈
DC offset voltage : ≥±300㎷
Time constant : 3.2sec
Patient leakage current : <10㎂
Frequency response 0.05~150㎐
Signal quality control Disconnected lead detection
Power Power supply : AC or built-in Battery(option)
Power requirement : 100 – 240 Vac, 50/60㎐, 1.0 – 0.5 A
Power consumption : 60W max
Battery capacity 1 hour of normal use(approximately 100 automatic ECG printouts)
Communication PC connection with RS-232 interface and LAN
Safety Class I, Type BF
Conformity CE, CSA, FDA, KFDA, SFDA, CCC
Environment Operating humidity : 30 ~ 85 %
Operating Temperature : 10。~ 40℃
Atmospheric pressure : 70 ~ 106 KPa
Standard accessory Power cord 1 EA, Patient cable 1 EA,Limb 1 set(4 EA),
Chest ball 1 set(6 EA), Chart paper 1 EA, Operation manual 1 EA
Options Rechargeable battery, Cart, Hanger, Bag, PC S/W
* Specifications can be changed without prior notification.
12 Channel ECG Machine – CardioCare2000 – Bionet USA
12 Channel ECG Machine – CardioCare2000 – Bionet USA is one of the best 12 Channel ECG Machine the product is manufactured in Korea, it is also pertinent to notice that Bionet is USA based company. 12 channel cardiocare2000 is the most used product all over the world.
Please click CardioCare2000_ECG_EKG_Brochure.pdf to download the Full catalog. For more information, questions, queries and quotations please feel free to contact us.
Product Description:
- Convenient A4 size print-outs allow for easy chart filing
- Copy function allows varied printouts from single patient sample
- Grid function allows you to use low cost plain fax paper
- One-touch operation (monitoring, recording mode)
- Accurate simultaneous 12 channel cardiac data acquisition
- Over 130 kinds of interpretation results based on advanced Minnesota code
- High-Quality 12ch interpretive ECG at a 3ch price
- Free S/W upgrade via internet
SPECIFICATION:
ECG leads 12 lead, simultaneous ECG and acquisition
Dimension 296(W) × 305.5(H) × 92.5(D)㎜, Approx.2.98㎏
Recording channel 3,6,12 channel and 1 channel(60 sec)
Sensitivity 5, 10, 20, auto(I~aVF: 10, V1~V6: 5) ㎜/㎷
Printing speed 12.5, 25, 50 ㎜/s
Sampling rate 500 samples/sec
Filters AC(50/60㎐, -20㏈ or better)
Muscle(25 ~ 35㎐, -3㏈ or better)
Base line drift (0.1㎐, -3㏈ or better)
Low pass filter (off, 40㎐, 100㎐, 150㎐)
Display 2×16 character LCD Display
LCD display Sensitivity, speed, filter status, HR, printing form, rhythm lead
LED indicator signal quality, power source, battery.
Keyboard Membrane keyboard, Alphanumeric and symbol available
Patient data ID, name, age, sex, height, weight
Basic measurement Heart rate, PR int, QRS dur, QT/QTc, P-R-T axis
Recorder Thermal print head, Thermal roll paper
Report papers : width : A4 : 210㎜ or 8.5″
length : A4 : 300㎜ or 11″
Effective writing width : 204 ㎜
Resolution : Vertical : 8 dots/㎜
Horizontal : 16dots/㎜
Electrical Internal noise : 20㎶(p-p)max
Input circuit : Floating input
Isolated and defibrillation protected
Input impedance : ≥10MΩ
Input voltage range : ≥±5㎷
Common Mode Rejection : ≥+100㏈
DC offset voltage : ≥±300㎷
Time constant : 3.2sec
Patient leakage current : <10㎂
Frequency response 0.05~150㎐
Signal quality control Disconnected lead detection
Power Power supply : AC or built-in Battery(option)
Power requirement : 100 – 240 Vac, 50/60㎐, 1.0 – 0.5 A
Power consumption : 60W max
Battery capacity 1 hour of normal use(approximately 100 automatic ECG printouts)
Communication PC connection with RS-232 interface and LAN
Safety Class I, Type BF
Conformity CE, CSA, FDA, KFDA, SFDA, CCC
Environment Operating humidity : 30 ~ 85 %
Operating Temperature : 10。~ 40℃
Atmospheric pressure : 70 ~ 106 KPa
Standard accessory Power cord 1 EA, Patient cable 1 EA,Limb 1 set(4 EA),
Chest ball 1 set(6 EA), Chart paper 1 EA, Operation manual 1 EA
Options Rechargeable battery, Cart, Hanger, Bag, PC S/W
* Specifications can be changed without prior notification.
You must be logged in to post a review.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
Autoclave Double Drum 30 LBS Pakistan
Autoclave Double Drum 30 LBS Pakistan
Autoclave Double Drum 30 LBS Pakistan is a best featured and manufactured product by Zirar Enterprises, We are one of the top leading manufacturer and distributor of autoclaves in Pakistan. We are manufacturing top-notch sterilizers and autoclaves in Pakistan. As we are the manufacturer of autoclaves so we can build or modify autoclaves according to your needs. Why Autoclave? or Autoclave Double Drum 30 LBS Pakistan Autoclave provides a physical method for sterilization in order to kill bacteria, microorganisms and spores. They are used to decontaminate certain biological waste and sterilize media, instruments and lab ware also it is highly recommended to sterilize medical instrument before disposing it off. Autoclave Double Drum 30 LBS Pakistan and Accessories Zirar Enterprises not only stops at autoclaves but we are also providing wide range of accessories to use before handling autoclaves for e.g. (Lab Coats, Safety Goggles, Safety Gloves and Shoes). Types of Autoclaves for Sale in Pakistan- Horizontal Autoclaves & sterilizers
- Vertical Autoclaves & sterilizers
- Electrical and Gas Autoclaves
- Fully SS (stainless steel autoclaves)
- MS & SS autoclaves
- Capacity: Auto clave 100L (16x30) Horizontal
- Drum: Double chamber (Jacket & Chamber)
- Material: MS Mild steel and SS Stainless steel (SS sheet size 2.5 MM for double chamber and 1.5 for single chamber)
- Working pressure: 30 – 35 pound (can be used up to 50-pound pressure if needed)
- Power: Electric 3 phase + Gas
- Wika Gauges: Water pressure gauge, steam pressure gauge and chamber pressure gauge.
- Valves: Safety valves & emergency steam release valves.
Micro Centrifuge Tube 2.0ml
Micro Centrifuge Tube 2.0ml
Micro Centrifuge Tube 2.0ml is one of the best and reliable centrifuge tubes made by Biomed Pakistan. The best thing about the centrifuge tubes are that they are autclaved and packed in different capacities as per the discretion of end-user. Micro Centrifuge Tube 2.0ml gives the best result and quality is 100% guaranteed. For more information regarding Micro Centrifuge Tube 2.0ml in Pakistan please feel free to contact us. Features:- Polypropylene clear polymer facilitates visualization of samples
- Attached snap caps
- Rated to 20,000 x G
- Graduations at every 100 μL for easy volume estimation
- Frosted writing sections in tube surface and tube cover for easy sample identification.
- Temperature range: -80°C to +121°C (Autoclave able)
- Certified free of detectable RNase, DNase & Pyrogen
- Affinity purification or affinity chromatography
- Immunodepletion
- Immunoprecipitation (IP)
- Mechanical failure of the machine
- Lab equipment failure (tubes, etc.)
- Aerosol generation
- Operator Error
- Operating Procedures
- Develop and implement a strict cleaning, storing, and maintenance protocol.
- Only use manufacturer compatible centrifuge, rotor, buckets, caps, and adapters.
- Replace centrifuge parts including bottles, tubes, and O-rings at the first sign of damage.
- Assemble the bottles, buckets, and rotor per the manufacturer’s instructions.
- Tightly seal all tubes and safety cups.
- Close lid during operation.
- Allow to come to complete stop before opening.
- Guideline for Safe Operation
- Use safety cups whenever possible.
- Disinfect or clean weekly and after all spills or breakages.
- Lubricate O-rings and rotor threads weekly.
- Do not operate the centrifuge without the rotor properly balanced.
- Do not use rotors that have been dropped.
- Inspect the speed disk for sign of damage if using an ultra-speed unit and
- discontinue use if damaged. Inspect the rotor and tube cavities for signs of damage and discontinue use if damaged.
- Contact your centrifuge representative for specific information.
- Micro Centrifuge Tube 2.0ml available in Pakistan in 1.0ml, 1.5ml, 2ml
Patient Monitor Operon OM12
Patient Monitor Operon OM12
Specification:- 12" inched LCD Monitor with high brightness TFT colors
- VGA slot available for attaching high resolution screen such as LED's, Monitors Etc
- SPO2
- Alarm/Beep as per prescribed statistics of the patient
- Accurate Blood Pressure display.
- Heart Beat display
- Printable ECH and other statistics/diagnosis.