Manual/Semi Automatic Manifold Systems
Manual/Semi Automatic Manifold Systems
Manual/Semi Automatic Manifold Systems main using at small and medium hospitals. When using the medical gas oxygen manifold, several cylinders need to be connected to the manifold pipeline. The oxygen gas is first filtered and decompressed, and then transported through the main pipe to the end of use. The function of the secondary regulator is to stabilize the outlet gas flow of the main pipeline. CGA standard adapter port and inlet connection thread. Cleaned for medical Oxygen, Air, N2O, CO2 gas. Open type manifold connector cylinder number according to the client request. 3 years warranty.
Specifications:
- Applicable gas: O2, Air, CO2, N2, and N2O etc.
- High flow capacity regulator
- Open style cylinder number according to the client request
- Pass the pressurization testing, welded in silver, much safety and stable
- Wall mount simplifies installation, easy installed
- Size of the connecting hose is customized
- CGA4.1 and ISO15001 Standard
- Maximum pressure 3,000 psi
General Information:
An oxygen manifold system is a critical component in the delivery of oxygen in medical facilities. The system consists of a series of oxygen cylinders connected to a common manifold, which regulates the flow of oxygen to different parts of the hospital or clinic. The manifold system ensures a continuous supply of oxygen to patients, even if one cylinder runs out of gas.
The manifold system is designed to be reliable and durable, and it is typically made of high-quality materials that can withstand the high pressures of oxygen gas. The manifold system can be configured in different ways depending on the specific needs of the medical facility. For example, some manifold systems may be designed to supply oxygen to a single ward or room, while others may supply oxygen to multiple floors of a hospital.
One of the benefits of an oxygen manifold system is its ability to provide a centralized source of oxygen, which can reduce the need for multiple oxygen tanks scattered throughout a facility. This can make it easier to manage the inventory of oxygen tanks and reduce the risk of running out of oxygen during a medical emergency.
Overall, an oxygen manifold system is an essential component of any medical facility that requires a reliable supply of oxygen for patient care. Proper maintenance and monitoring of the system are crucial to ensure its continued reliability and safety.
Manufactured by AMCAREMED
Please click to read Medical Gas and Pipeline Network
For more information please feel free to call us at+92-322-4602203 or Email: info@ziarenterprises.com, zirarenterprises@gmail.com
Manual/Semi Automatic Manifold Systems
Manual/Semi Automatic Manifold Systems main using at small and medium hospitals. When using the medical gas oxygen manifold, several cylinders need to be connected to the manifold pipeline. The oxygen gas is first filtered and decompressed, and then transported through the main pipe to the end of use. The function of the secondary regulator is to stabilize the outlet gas flow of the main pipeline. CGA standard adapter port and inlet connection thread. Cleaned for medical Oxygen, Air, N2O, CO2 gas. Open type manifold connector cylinder number according to the client request. 3 years warranty.
Specifications:
- Applicable gas: O2, Air, CO2, N2, and N2O etc.
- High flow capacity regulator
- Open style cylinder number according to the client request
- Pass the pressurization testing, welded in silver, much safety and stable
- Wall mount simplifies installation, easy installed
- Size of the connecting hose is customized
- CGA4.1 and ISO15001 Standard
- Maximum pressure 3,000 psi
General Information:
An oxygen manifold system is a critical component in the delivery of oxygen in medical facilities. The system consists of a series of oxygen cylinders connected to a common manifold, which regulates the flow of oxygen to different parts of the hospital or clinic. The manifold system ensures a continuous supply of oxygen to patients, even if one cylinder runs out of gas.
The manifold system is designed to be reliable and durable, and it is typically made of high-quality materials that can withstand the high pressures of oxygen gas. The manifold system can be configured in different ways depending on the specific needs of the medical facility. For example, some manifold systems may be designed to supply oxygen to a single ward or room, while others may supply oxygen to multiple floors of a hospital.
One of the benefits of an oxygen manifold system is its ability to provide a centralized source of oxygen, which can reduce the need for multiple oxygen tanks scattered throughout a facility. This can make it easier to manage the inventory of oxygen tanks and reduce the risk of running out of oxygen during a medical emergency.
Overall, an oxygen manifold system is an essential component of any medical facility that requires a reliable supply of oxygen for patient care. Proper maintenance and monitoring of the system are crucial to ensure its continued reliability and safety.
Manufactured by AMCAREMED
Please click to read Medical Gas and Pipeline Network
For more information please feel free to call us at+92-322-4602203 or Email: info@ziarenterprises.com, zirarenterprises@gmail.com
You must be logged in to post a review.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
Bed Head Unit Horizontal NTC 200
Bed Head Unit Horizontal NTC 200
Bed Head Unit Horizontal NTC 200 unit system is surface mounted to the comfort of patients and their proper care during their stay in the hospital. Using extruded aluminum profile alloy 6063. Design and functionality convince the patient and hospital user. Easy to installed and maintenance reduce time. 2 mm Bed Head profile aluminum thickness. The hospital bed head unit lighting parts are designed to provide the best diffusion of light. The lamp unit consisting of direct, indirect and night light. NTC series is available in both LED and fluorescent versions. It’s optical design all perfect control of the lighting. Manufactured by AMCAREMED Please see our complete range of BED HEAD UNITS Completely modular and adaptable to your needs can include:- Length according to different request
- Gas outlet, according to different standards
- Light is available in both LED and fluorescent versions. Its optical design allows perfect control of the lighting
- Power socket accept different standards and voltages
- Communication plugs (Network port, Phone…etc.)
- Designed in accordance with HTM 2022 standard
- 2 MM thickness of the profile aluminum
- The Bed Head Trunking length according to request
- Provide medical gas outlets, electric socket, lamps, electrical switches and other equipment
- The bed head unit light is available in both LED and fluorescent versions
- Its optical design allows perfect control of the lighting
- Can be customized and upgraded to meet your need
- Model: NTC 200
Design and planning of CSSD
Medical Air Plant – British Standard
Medical Air Plant - British Standard
Medical Air Plant - British Standard - Precision UK’s CPX Medical Air Plant is manufactured under BS EN 13485 Medical Devices: Quality Management Systems. It provides a centralized source of medical air, available in simplex to multi-pump configurations dependent on individual requirement.
Specification:
- Specific Benefits Include
- Fully complies to HTM 02-01, HTM 2022, C11, BS EN 7396, CE0086 Class IIb
- CE marked under Medical Device Directive 93/42/EEC
- CPX® branded solid British design
- Control and highly visible indication panel
- All interconnecting pipework is included
- Outlet pipework for connecting to the pipeline
- Anti-vibration mounts on all compressors
- Isolator to each pump unit as standard
- Alarm and BMS outputs for remote status indication
- Digital display touchscreen with user interface
- 400Kpa, 700Kpa and 1000Kpa output versions available
- All settings are factory set and verified with certificates of inspection
- Each plant has a full warranty of 12 months from its commission date
Medical Gas Outlets Medikar
Medical Gas Outlets Medikar
Medical Gas Outlets Medikar Q-Click gas outlet to the hospital by the medical gas supply unit to connected copper pipe and brought to the patient are the end points. Probes inserted into the socket with the relevant gas check valves are opened and gas will start crossing. Valve opens and gas locking mechanism to suppress the transition and the probe is removed and cut. Gas outlet pipe of the Q-Click base, capsule type, the main body consists of three groups. Q-Click Gas Connectors BS 5682:1998, ISO 9170:2008, EN 737, ISO 9001:2000 and are designed according to the norms of MDD 93/42/EEC. Q-Click Gas outlet other than a standard capsule and a standard to ensure the transition of the main body is enough to change. Easy disassembly and reassembly capability. Maintenance and service is also very simple. Gas outlet in the patient rooms, emergency rooms are used and the maternity ward. Q-Click gas outlet BS 5682:1998, DIN EN 13 260 and 737-6 are manufactured according to the norms. Q-Click gas outlet completely metal aluminum and brass material is manufactured from a durable and sturdy structure. It is also noticeable that we have been supplying wall mounted Oxygen Points in Pakistan for more than two decades and therefore we have ample experience in installation of Oxygen Points or Oxygen Outlets, Air Outlets, Vacuum Outlets and Nitrous Oxide outlet points, we can install it directly on the wall or typically it install on the Bed Head Panel. We have wide range of stock of British Standard Outlet Points, Din Standard Outlet Points or any other type can also be manufactured on prior order. We also manufacture OT Pendants and the outlet for OT Pendants Double Arm and Single Arm and they are 100# Portable.
Manufactured by Medikar Turkey
Please click to see our full Range of Medical Gases & Infrastructure
For more information please feel free to contact us +92-322-4602203 Email: info@zirarenterprises.com, zirarenterprises@gmail.com Medical Gas Outlets Precision UK
Medical Gas Outlets Precision UK
Medical Gas Outlets Precision UK also known as CPX Terminal Units are designed and manufactured in the UK under BS EN 13485 Medical Devices: Quality Management Systems. The units comprise of a first fix, second fix and a second fix valve assembly and connect medical appliances to the gas supply system. Please also see our Medical Gas Outlets Precision UK & Medical Gases & Infrastructure The first fix comprises of a brass pipeline termination cylinder with a 12mm BS EN 13348 copper pipe for brazing to the fixed pipeline system, or with a NIST BS EN 18082 (non-interchangeable screw thread) connector for connection to a hose assembly. A mounting box suitable for both surface and flush installations is also provided. CPX British Standard and DIN Standard Gas Outlets utilize a common first fix assembly. The CPX Terminal Unit is designed to enable gas probes to be connected and disconnected easily and with minimal effort and the same time as giving a strong, reliable and secure connection. They are available for oxygen, nitrous oxide, 50% oxygen/50% nitrous oxide mixture, medical air, surgical air, medical vacuum, carbon dioxide, nitrogen and AGSS. The terminal units can be flexibly integrated into any type of installation including surface, flush, bedhead and pendant and are supplied with a 3 year warranty. Test plugs are included with flush, surface, and bedhead types for first fix pressure testing on site. DIN Standard CPX DIN gas outlets are manufactured and designed in our UK factory, full metal construction, Gas Indexing as EN 13260-2, EN 9170 and Medical Gas Pipelines EN 7396.
Standards: Designed to Meet the requirements of
Medical Gas Outlet Precision UK
- HTM 02-01 Medical gas Pipeline Systems
- BS EN 7396-1 Pipelines for Compressed medical Gases and Vacuum
- BS EN 7396-2 Anaesthetic Gas Scavenging Disposal Systems
- BS EN 9170-1 Terminal Units for use with Compressed Medical Gases and Vacuum
- BS EN 9170-2 Terminal Units for Anaesthetic Gas Scavenging Systems
- C11 NHS Model Engineering Specification – Medical Gases
- BS EN 18082 Non-interchangeable Screw Threaded (NIST) Low-pressure Connectors for Medical Gases
- BS 5682 Specification for Probes Specification for Probes (quick connectors) for Medical Gases.
- Medical Device Directive 93/42/EEC (CE0086) Class IIb.
- DIN 13260-2 Part 2: Dimensions and allocation of Probes and Gas specific connection points for Terminal Units
- Available for Oxygen, Nitrous Oxide, Medical Air, CO2, Motor Air and Vacuum (other gases available on request)
- Incorporating a 12mm copper stub pipe to EN 13348 to allow easy connection to the Medical Gas Pipeline system, other options include NIST or DISS type fittings for pendants or bed head units.
- Probe insertion design incorporates parking position and full insert for 100% operation, each outlet is supplied with Flush/Surface Box or Bed Head Plate mounting options and include a 3-year warranty.
- CE marked CE0086 Class IIb Medical Device.
Medical Pendant Multi Movement
Medical Pendant Multi Movement
Medical Pendant Multi Movement manufactured by Precision United Kingdom supplies a comprehensive range of high quality ceiling suspension systems which have been developed under the following criteria:- Increased Safety
- Increased Hygiene and Sterility
- Ease of use
- The many advantages in the field of safety and hygiene are;
Oxygen Suction Flowmeter Precision UK
Oxygen Suction Flowmeter Precision UK
Oxygen Suction Flowmeter Precision UK - The Precision CPX Bubble flow meter shall be supplied with connection probes to BS 5682, other country standards available e.g. DIN, NFPA, AFNOR, JIS, SS, ISO European Gas Specificity Flow meter’s shall be supplied with gas specific probes and only attach to the corresponding medical gas terminal unit, it accurately measures flow at 0-15Lpm even at variant inlet pressures. Accuracy is fulfilled within 10% to attain maximum efficiency for patient and environment. Each flow meter is calibrated at 50 psi inlet pressure Materials Flow meter shall be manufactured to EN 13220:1999 and ISO 15002:2008 and constructed from chromium-plated brass body, inner and external tube in crack resistant polycarbonate and stainless steel ball. Other pieces shall be in brass. Humidifier: Constructed from polycarbonate, Sterilisation should be conducted in an autoclave on a 25 min cycle at 121 ºC, 1.3 kPa (max. 40 times). Before sterilisation remove the tube and diffuser and consequently disposed. Quality: Manufactured under BS EN 13485 Medical Devices: Quality Management Systems and carries CE0086 Class IIb Medical Device certification. Warranty The flow meter shall have a two-year warranty, subject to the recommended minimum routine maintenance operations being carried out by correctly competent persons. For more information regarding rates, quotations, queries or any questions please feel free to contact us at +92-322-4602203 Email: zirarenterprises@gmail.com, info@zirarenterprises.comPressure Regulators and FlowMeter Schonn
Pressure Regulators and FlowMeter Schonn
Pressure Regulators and Flow Meter Schonn Germany pressure regulators and our flowmeters for applications other than oxygen therapy (presented in the specific section) The supply of all medical gases through measurement devices requires accuracy and experience in manufacturing and development, so we underline once more that all these devices are made n full compliance with European standards and technical regulations, as well as requirements of 93/42/EEC Directive and the approval criteria set by national and international certified bodes. The CE marking procedure s carried out according to the requirements of a complete EN ISO 13485 quality system. All regulators and flow meters are rigorously tested, both n flow-meter™ own quality-assurance laboratories and by independent validated laboratories, to ensure that the products meet all the requirements of the medical applications n any foreseeable therapeutic condition. Pressure regulators and flow meters are manufactured n full compliance of ISO 10524-1 and ISO 15002. The Schönn range of Oxygen Therapy equipment provides a seamless solution between your medical gas pipeline system (MGPS) and downstream patent suppler enabling a one stop provider for all your medical gas needs. Our high end devices provide the user with light weight, highly precise and accurate equipment, which allows clinical and nursing staff to be concerned about only one thing - the patent. SCHÖNN flow meters are robust and tactile, providing the user with a quality assurance further backed by our extended 2 year warranty. Our aesthetically pleasing equipment can be supplied with our range of Bedhead trunking, SCHÖNN or Global terminal units thus eliminating any concern over equipment compatibility. The SCHÖNN range of downstream equipment can be supplied to British BS, German DIN or French AFNOR and AGA norms as well as a few others, which are available upon request.Pressure Regulators and FlowMeter Schonn
Please see our complete range of Medical Gases & Infrastructure Features:- Oxygen Flowmeters are used to provide Oxygen to the patent from Medical Gas outlets through nasal cannula or mask by regulating flow rate and passing through a humidifier when required.
- Schönn Flow meters are specially designed for medical applications and are used with oxygen. Body of the Flow meter s made of chromium plated brass, which s the most hygienic material for use with oxygen.
- The scaled tube of the Flow meter s made of poly carbonate for high resistance to breakage and s autoclavable. It s graded between 1-15 Ipm.
- The Humidifier on the Flow meter can be sterilized at 150°C.
- Our Flow meters are available for direct connection to appropriate Terminal Unit, n compliance wth EN European Norms) BS ,DIN and AGA.
- Humidifying bottle is 200ml.

Reviews
There are no reviews yet.