Oxygen Nitrous Oxide Medical Air Plant Medical Gas Cylinder central Plant stations are installed to provide a reliable source of supply for the Oxygen, Nitrous Oxide & Medical Air requirements of hospitals. Principal details of these Plants are usually similar. The only difference is the number of cylinders which are used in the Plants. These pressured gases are used in Operation Theaters, Intensive Care Units, Baby Care Units, Emergency Rooms and Patient Rooms.
The gas is stored at high pressure in specifically made cylinders that are connected to the Central Plant Station. The pressure in the cylinder will vary according to the gas contained in the cylinder (O2, – N2O. Air). This Plant has been designed and built specially for hospitals to comply fully with ISO 7396:2004, ISO 13485:2003, EN 46001, ISO 14971, EN 980, EN 940, EN 739, EN 737, EN 793, DIN 13260, HTM 2022 and American Standards and is CE Marked. These Plants are manufactured in compliance to ISO 9001:2000, ISO 13485:2001, EN 46001, EN 1441:1997, EN 980,EN 940, EN 739, EN 737 ,EN 793, DIN 13260, HTM 2022, American Standards and CE Marked.
Manufactured by: Medikar, Turkey
Please check our complete range of Medical Gases and Pipe Network
The Plants are proposed according to the hospital capacity as follows:
- Automatic (Oxygen, Nitrous Oxide, Medical Air ) Plant Auto System 8200
- Automatic (Oxygen, Nitrous Oxide, Medical Air ) Plant Auto System 8001
- Manual Plant
- Emergency Supply Plant System
For more information quotations, queries and rates please call or whatsapp +92-322-4602203 Email: info@zirarenterprises.com, zirarenterprises@gmail.com
Oxygen Nitrous Oxide Medical Air Plant
Oxygen Nitrous Oxide Medical Air Plant Medical Gas Cylinder central Plant stations are installed to provide a reliable source of supply for the Oxygen, Nitrous Oxide & Medical Air requirements of hospitals. Principal details of these Plants are usually similar. The only difference is the number of cylinders which are used in the Plants. These pressured gases are used in Operation Theaters, Intensive Care Units, Baby Care Units, Emergency Rooms and Patient Rooms.
The gas is stored at high pressure in specifically made cylinders that are connected to the Central Plant Station. The pressure in the cylinder will vary according to the gas contained in the cylinder (O2, – N2O. Air). This Plant has been designed and built specially for hospitals to comply fully with ISO 7396:2004, ISO 13485:2003, EN 46001, ISO 14971, EN 980, EN 940, EN 739, EN 737, EN 793, DIN 13260, HTM 2022 and American Standards and is CE Marked. These Plants are manufactured in compliance to ISO 9001:2000, ISO 13485:2001, EN 46001, EN 1441:1997, EN 980,EN 940, EN 739, EN 737 ,EN 793, DIN 13260, HTM 2022, American Standards and CE Marked.
Manufactured by: Medikar, Turkey
Please check our complete range of Medical Gases and Pipe Network
The Plants are proposed according to the hospital capacity as follows:
- Automatic (Oxygen, Nitrous Oxide, Medical Air ) Plant Auto System 8200
- Automatic (Oxygen, Nitrous Oxide, Medical Air ) Plant Auto System 8001
- Manual Plant
- Emergency Supply Plant System
For more information quotations, queries and rates please call or whatsapp +92-322-4602203 Email: info@zirarenterprises.com, zirarenterprises@gmail.com
You must be logged in to post a review.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Related products
AGSS Medical Air Plant – British Standard
AGSS Medical Air Plant - British Standard
Precision UK’s CPX AGSS Medical Air Plant - British Standard is manufactured under BS EN 13485 Medical Devices: Quality Management Systems. It provides a centralized or dedicated source for the safe removal of exhaled anaesthetic gases from within the theater, available in simplex and duplex pump configurations dependent on individual requirement. For more information about the product, questions, queries and quotations please call us at +92-322-4602203 or Email us info@zirarenterprises.com, zirarenterprises@gmail.com Technical Specification:- HTM 02-01: Medical Gas Pipeline Systems
- C11 NHS: Model Engineering Specification – Medical Gases
- BS EN 6834: Specification for Active Anaesthetic Gas Scavenging Systems
- ISO 7396-2: Anaesthetic Gas Scavenging Disposal Systems
- CPX® branded solid British design
- Control and highly visible indication panel
- CE marked under Medical Device Directive 93/42/EEC with approval from British Standards Institute CE0086 classified as Class IIa Medical Device
- All interconnecting pipework is included
- Copper stubbed outlet and inlet pipework for ease of connecting to MGPS
- Available in Single or 3 Phase
- Anti-vibration mounts on all pumps
- Isolator to each pump unit as standard
- Alarm and BMS outputs for remote status indication
- Pre-set vacuum relief valve and low pressure sensors
- Low voltage (24V) remote switches
- Visible condensate drain flask fitted to exhaust
- Easy to install 4 wire + earth remote switch wiring
- All settings are factory set and verified with certificates of inspection
- Each plant has a full warranty of 12 months from its commission date
Bed Head Unit Horizontal
Bed Head Unit Horizontal
Bed Head Unit Horizontal widely used in hospitals and which provides patients a good care, backed by invisible medical gas copper pipe lines, electric sockets it is pertinent to notice that we at Zirar Enterprises have installed these units in many renowned hospitals. please feel free to contact us anytime for assistance +923224602203 If you want bed head unit vertical then click on this link bellow Bed Head unit verticalDesigning and Planning of Dialysis unit
Designing and Planing of Dialysis Unit
Designing and Planing of Dialysis Unit in Kidney center is very important. We keep the record of all dialysis units and kidney centers so that we design, plan and manufacture the whole dialysis unit in very low prices for more information and specification please contact 0322-4602203Hermetic Doors
Hermetic Doors
Hermetic Doors also known as Hermetic sliding door or automatic doors are required where hygiene and the leakage of air control is critical. These doors takes less space and sealed completely form the edges so no air, gases or dust particles can pass through out of the operation theater. We have best team in market to install these doors with top quality material at very competitive prices. For further queries feel free to contact us 0322-4602203Manual/Semi Automatic Manifold Systems
Manual/Semi Automatic Manifold Systems
Manual/Semi Automatic Manifold Systems main using at small and medium hospitals. When using the medical gas oxygen manifold, several cylinders need to be connected to the manifold pipeline. The oxygen gas is first filtered and decompressed, and then transported through the main pipe to the end of use. The function of the secondary regulator is to stabilize the outlet gas flow of the main pipeline. CGA standard adapter port and inlet connection thread. Cleaned for medical Oxygen, Air, N2O, CO2 gas. Open type manifold connector cylinder number according to the client request. 3 years warranty. Specifications:- Applicable gas: O2, Air, CO2, N2, and N2O etc.
- High flow capacity regulator
- Open style cylinder number according to the client request
- Pass the pressurization testing, welded in silver, much safety and stable
- Wall mount simplifies installation, easy installed
- Size of the connecting hose is customized
- CGA4.1 and ISO15001 Standard
- Maximum pressure 3,000 psi
General Information:
An oxygen manifold system is a critical component in the delivery of oxygen in medical facilities. The system consists of a series of oxygen cylinders connected to a common manifold, which regulates the flow of oxygen to different parts of the hospital or clinic. The manifold system ensures a continuous supply of oxygen to patients, even if one cylinder runs out of gas. The manifold system is designed to be reliable and durable, and it is typically made of high-quality materials that can withstand the high pressures of oxygen gas. The manifold system can be configured in different ways depending on the specific needs of the medical facility. For example, some manifold systems may be designed to supply oxygen to a single ward or room, while others may supply oxygen to multiple floors of a hospital. One of the benefits of an oxygen manifold system is its ability to provide a centralized source of oxygen, which can reduce the need for multiple oxygen tanks scattered throughout a facility. This can make it easier to manage the inventory of oxygen tanks and reduce the risk of running out of oxygen during a medical emergency. Overall, an oxygen manifold system is an essential component of any medical facility that requires a reliable supply of oxygen for patient care. Proper maintenance and monitoring of the system are crucial to ensure its continued reliability and safety. Manufactured by AMCAREMED Please click to read Medical Gas and Pipeline Network For more information please feel free to call us at+92-322-4602203 or Email: info@ziarenterprises.com, zirarenterprises@gmail.comMedical Gas Outlets Precision UK
Medical Gas Outlets Precision UK
Medical Gas Outlets Precision UK also known as CPX Terminal Units are designed and manufactured in the UK under BS EN 13485 Medical Devices: Quality Management Systems. The units comprise of a first fix, second fix and a second fix valve assembly and connect medical appliances to the gas supply system. Please also see our Medical Gas Outlets Precision UK & Medical Gases & Infrastructure The first fix comprises of a brass pipeline termination cylinder with a 12mm BS EN 13348 copper pipe for brazing to the fixed pipeline system, or with a NIST BS EN 18082 (non-interchangeable screw thread) connector for connection to a hose assembly. A mounting box suitable for both surface and flush installations is also provided. CPX British Standard and DIN Standard Gas Outlets utilize a common first fix assembly. The CPX Terminal Unit is designed to enable gas probes to be connected and disconnected easily and with minimal effort and the same time as giving a strong, reliable and secure connection. They are available for oxygen, nitrous oxide, 50% oxygen/50% nitrous oxide mixture, medical air, surgical air, medical vacuum, carbon dioxide, nitrogen and AGSS. The terminal units can be flexibly integrated into any type of installation including surface, flush, bedhead and pendant and are supplied with a 3 year warranty. Test plugs are included with flush, surface, and bedhead types for first fix pressure testing on site. DIN Standard CPX DIN gas outlets are manufactured and designed in our UK factory, full metal construction, Gas Indexing as EN 13260-2, EN 9170 and Medical Gas Pipelines EN 7396.
Standards: Designed to Meet the requirements of
Medical Gas Outlet Precision UK
- HTM 02-01 Medical gas Pipeline Systems
- BS EN 7396-1 Pipelines for Compressed medical Gases and Vacuum
- BS EN 7396-2 Anaesthetic Gas Scavenging Disposal Systems
- BS EN 9170-1 Terminal Units for use with Compressed Medical Gases and Vacuum
- BS EN 9170-2 Terminal Units for Anaesthetic Gas Scavenging Systems
- C11 NHS Model Engineering Specification – Medical Gases
- BS EN 18082 Non-interchangeable Screw Threaded (NIST) Low-pressure Connectors for Medical Gases
- BS 5682 Specification for Probes Specification for Probes (quick connectors) for Medical Gases.
- Medical Device Directive 93/42/EEC (CE0086) Class IIb.
- DIN 13260-2 Part 2: Dimensions and allocation of Probes and Gas specific connection points for Terminal Units
- Available for Oxygen, Nitrous Oxide, Medical Air, CO2, Motor Air and Vacuum (other gases available on request)
- Incorporating a 12mm copper stub pipe to EN 13348 to allow easy connection to the Medical Gas Pipeline system, other options include NIST or DISS type fittings for pendants or bed head units.
- Probe insertion design incorporates parking position and full insert for 100% operation, each outlet is supplied with Flush/Surface Box or Bed Head Plate mounting options and include a 3-year warranty.
- CE marked CE0086 Class IIb Medical Device.
Medical Vacuum Plant British Standard
me British Standard
Precision UK’s CPX Medical Vacuum Plant British Standard is manufactured under BS EN 13485 Medical Devices: Quality Management Systems. It provides a centralized source of vacuum, available in simplex to multi-pump configurations dependent on individual requirement, to include complete package plant or modular format.
Specification: -
Specific Benefits Include
- Fully complies to HTM 02-01, HTM 2022, C11, BS EN 7396, CE0086 Class IIb
- CE marked under Medical Device Directive 93/42/EEC
- CPX® branded solid British design
- Control and highly visible indication panel
- All interconnecting pipework is included
- Outlet pipework for connecting to the pipeline
- Anti-vibration mounts on all pumps
- Isolator to each pump unit as standard
- Alarm and BMS outputs for remote status indication
- Digital display available on request
- All settings are factory set and verified with certificates of inspection
- Each plant has a full warranty of 12 months from its commission date
- Options – Touchscreen, BMS Modbus, Digital Outputs, SMS Texting Alarms, Service Reminders
Pressure Regulators and FlowMeter Schonn
Pressure Regulators and FlowMeter Schonn
Pressure Regulators and Flow Meter Schonn Germany pressure regulators and our flowmeters for applications other than oxygen therapy (presented in the specific section) The supply of all medical gases through measurement devices requires accuracy and experience in manufacturing and development, so we underline once more that all these devices are made n full compliance with European standards and technical regulations, as well as requirements of 93/42/EEC Directive and the approval criteria set by national and international certified bodes. The CE marking procedure s carried out according to the requirements of a complete EN ISO 13485 quality system. All regulators and flow meters are rigorously tested, both n flow-meter™ own quality-assurance laboratories and by independent validated laboratories, to ensure that the products meet all the requirements of the medical applications n any foreseeable therapeutic condition. Pressure regulators and flow meters are manufactured n full compliance of ISO 10524-1 and ISO 15002. The Schönn range of Oxygen Therapy equipment provides a seamless solution between your medical gas pipeline system (MGPS) and downstream patent suppler enabling a one stop provider for all your medical gas needs. Our high end devices provide the user with light weight, highly precise and accurate equipment, which allows clinical and nursing staff to be concerned about only one thing - the patent. SCHÖNN flow meters are robust and tactile, providing the user with a quality assurance further backed by our extended 2 year warranty. Our aesthetically pleasing equipment can be supplied with our range of Bedhead trunking, SCHÖNN or Global terminal units thus eliminating any concern over equipment compatibility. The SCHÖNN range of downstream equipment can be supplied to British BS, German DIN or French AFNOR and AGA norms as well as a few others, which are available upon request.Pressure Regulators and FlowMeter Schonn
Please see our complete range of Medical Gases & Infrastructure Features:- Oxygen Flowmeters are used to provide Oxygen to the patent from Medical Gas outlets through nasal cannula or mask by regulating flow rate and passing through a humidifier when required.
- Schönn Flow meters are specially designed for medical applications and are used with oxygen. Body of the Flow meter s made of chromium plated brass, which s the most hygienic material for use with oxygen.
- The scaled tube of the Flow meter s made of poly carbonate for high resistance to breakage and s autoclavable. It s graded between 1-15 Ipm.
- The Humidifier on the Flow meter can be sterilized at 150°C.
- Our Flow meters are available for direct connection to appropriate Terminal Unit, n compliance wth EN European Norms) BS ,DIN and AGA.
- Humidifying bottle is 200ml.