Medical Equipment's
Automated External Defibrillator AED – Saver One
Automated External Defibrillator AED - Saver One
Automated External Defibrillator AED - Saver One Model: Full Automatic. AED helps in Sudden Cardiac Arrest which can happen to anyone, anytime, anywhere and without warning. The person affected has only few precious minutes left for a chance of survival. SAVER ONE AEDs are designed for a public access use and licensed to administer fast and safe rescues. Highly-effective and user-friendly for any lay rescuer, even without minimal training. Choose the best portable AED that’s right for you to save lives everywhere in any public circumstance home, office, school, hotel, airport, train, beach, gym, pool, disco, etc.) and before EMS team arrives. SAVER ONE Semi Automatic and Fully Automatic defibrillators are two dependable members of our AED family. The Fully Automatic administers a defibrillating shock (when appropriate) with no shock button for the user to press while the Semi-Automatic administers a shock at the press of a button.Automated External Defibrillator AED - Saver One Operation:
- Fully Automatic Version
- Energies: Standard max 200J or Power max 360J
- Waveform: Adaptive BTE (biphasic truncated exponential) conforming to patient chest’s impedance
- Energy type: Escalating from 50 to 360J
- Protocols: Various adult shock protocols available on request
- Factory default: Adult Standard escalating 150, 200, 200J
- Adult Power escalating 200, 250, 360J
- Pediatric (Standard or Power) 50J fixed
- Charging time: 9 seconds with a new and fully charged battery.
- Depleted battery will result in a longer charging time
- Analysis time: EN 60601, from 4 to 15 seconds
- Impedance: 20-200 ohms
- Sensitivity: EN 60602-2-4 (AHADB, MITDB source), 97%
- Specificity: EN 60602-2-4 (AHADB, MITDB source), 99%
Oxygen Concentrator Dual Flow JAY-5
Oxygen Concentrator Dual Flow JAY-5
Oxygen Concentrator Dual Flow JAY-5 with nebulizer is an electronic equipment which is influenced by Radio Frequency Interference (RFI). When there is strong electromagnetic interference, maybe the LCD will be slightly affected, but the Oxygen Concentrator Dual Flow Jay-5 is still running. ALWAYS exercise CAUTION with regard to the use of portable communications equipment in the area around such equipment. JAY Series oxygen concentrator is a device that extracts oxygen from atmospheric air. It will typically be an electrically powered molecular sieve (artificial zeolite) used to separate nitrogen from ambient air. It could be applied widely in the hospitals at all different level, clinics, health centers and family nursing, health care for the old person, mental workers and students, etc.. The oxygen concentrator can supply 1-2 patients simultaneously, with steady oxygen flowing out, safe and reliable, low cost, adjustable flow. The key parts of the concentrator adopt anti-tiring and anti-aging design, and the planned life of the whole concentrator reaches up to 20,000 hours or 5 years, whichever comes first. Click to download the user manual of Longfian_Oxygen Concentrator Dual Flow Jay-5.pdf TECHNICAL SPECIFICATION
Operation conditions and Environment
- Ambient temperature: 10 -40℃
- Relative humidity: 30%-85%
- Air pressure: 700 hPa-1060 hPa
- Altitude: Up to 2286m without degradation; Consult your equipment provider for further
- information regarding to 2286m to 4000m
- No corrosive gas and strong magnetic field around.
Semi Fowler Bed
Brand: Zirar Enterprises
Model: semi fowler
CLICK HERE FOR QC LAB FURNITURE
Pocket Doppler VIV0 V20 Italy
Pocket Doppler VIV0 V20 Italy
Pocket Doppler VIVO V20 Italy has crystal sound technology and built in sound filters for increased audio fidelity. The quality of VIVO v20 is guaranteed by VIVO Medical the product is manufactured in compliance with the strict design and quality procedures of VIVO Medical. Please click here VIVO V20.pdf to download the catalog. For more information about the product, questions, queries and quotations please feel free to contact us at +92-322-4602203 or email us at zirarenterprises@gmail.com, info@zirarenterprises.comAdult Diapers Brand A+ China
Adult Diapers Brand A+ China
Adult Diapers Brand A+ China available in Pakistan, adult diapers are available in stock, Adult Diapers plays a vital role to handle the patient who are unable to go to the toilets. There are many ways to use adult diapers in hospitals but the premium quality of A+ is absolutely phenomenal. Adult diapers Brand A+ China has ultra absorbency capability, the chemical inside the paper is called sodium polyacrylate is of the best quality. For orders of Adult Diapers Brand A+ China please feel free to contact us at 0322-4602203Sizes:
- Medium
- Large
- XL
- XXL
- Premium Quality
- Ultra Absorbency
- Extra Comfort Touch
- Approved by Health Organizations around the world
ANESTHESIA MACHINE WITH VENTILATOR – NSL-GE-800 PLUS USA
ANESTHESIA MACHINE WITH VENTILATOR – NSL-GE-800 PLUS USA
ANESTHESIA MACHINE WITH VENTILATOR – NSL-GE-800 PLUS USA. The GE Series of Anesthesia machines are a robust feat of engineering with heavy duty alloy frame and state-of-the-art design that ensures surgeons have one thing less to worry about during their work. The compact design keeps the unit footprint to a minimal while providing all the features and technology found in most premium grade Anesthesia Machines today. please click here to download the product catalog anesthesia machine MDX china.pdf- Special Feature: Application: Adult, Pediatric
- Driven mode: Pneumatically driven electronically controlled
- Mode: Semi-open, Semi-closed or closed system
- Anesthetic vaporizer: One vaporizer (optional two)
- Display: High light LED display Ventilation Volume: 50~1600ml
- Breath frequency: 1~90BPM
- I:E ratio: 4:1 ~ 1:6
- Monitor parameter: Tidal volume, breath frequency, MV
- Alarm: MV high alarm, MV low alarm, TV high alarm, TV low alarm
- Circle absorber: Compact circle absorber
- Bellow: 0 ~ 1600ml
- Oxygen FLUSH: 25L/min ~ 75L/min
- O2, N2O two-tube flowmeter
- O2 tube: 0L/min ~ 10L/min
- N2O tube: 0L/min ~ 10L/min
- O2 and N2O linkage device Adjust O2 and N2O in proportion ( keep O2 concentration not lower than 25% )
- O2: 0.25 ~ 0.65Mpa
- N2O: 0.25~ 0.65Mpa
- Gauge: 2 units, one N2O, one O2
Patient Monitor MD9012 Meditech
Patient Monitor MD9012 Meditech
Patient Monitor MD9012 Meditech is 12 inch TFT display high resolution. Automatic temperature drift treatment of NIBP measuring patented technology;Friendly and configurable user interface;Powerful data review:Maximum 720-hour graphic and tabular trends, Up to10000 pieces of NIBP record storage, Wired or wireless networkable with Central Monitoring System;On-line upgrading keeps you updated.Features:
- High resolution 12” color TFT display
- 12 Channel waves.9 Parameters : ECG, Resp, NIBP, SpO2, TEMP,
- Light weight, compact and portable
- Built-in rechargeable lithium battery
- Unique human voice alarm
- Rich screen layouts: Standard, Big font, Trend table, NIBP trend, ECG full lead, OxyCRG, IoC Layout
- Powerful storage: Maximum 720 Hour graphic and tabular trends of all
- parameters, up to 10000 NIBP review, 200 alarm review ,2 Hours of all wave forms
- System software can be upgraded through network
- Data and waveforms color be adjustable
- Arrhythmia analysis and S-T segment analysis
- Suitable for adult, pediatric and neonatal patient
- Invasive Blood Pressure (IBP)
- Carbon dioxide (CO2) Module
- Thermal Printer
- Touch Screen
Specification:
ECG Lead Mode 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V) Lead selection I, II, III, avR, avL, avF, V, Waveform 2 ch Lead mode 3 Leads ( R, L, F or RA, LA, LL) Lead selection I, II, III, Waveform 1 ch Gain x2.5mm/mV, x5.0mm/mV, x10mm/mV, x20mm/mV, auto HR and Alarm Range Adult 15 ~ 300 bpm Neo/Ped 15 ~ 350 bpm Accuracy ± 1% or ± 1bpm,which great Resolution 1 bpm Sensitivity > 200 (uV ) Differential Input Impedance > 5 MΩ CMRR Monitor > 105 dB Operation > 105 dB Diagnosis > 85 dB Electrode offset potential ±300mV Leakage Current < 10 uA Baseline Recovery < 3 S After Defi. ECG Signal Range ±8 m V ( Vp-p ) Bandwidth Surgery 1 ~ 15 Hz Monitor 0.5 ~ 35 Hz Diagnostic 0.05 ~ 100 Hz Calibration Signal 1 (mV ), Accuracy :±5% ST Segment Monitoring Range Measure and Alarm -2.0 ~ +2.0 mV ARR Detecting Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY,MISSED BEATS, PNP, PNC Alarm Available Review Available RESPIRATION Method Impedance between R-F(RA-LL) Differential Input Impedance >2.5 MΩ Measuring Impedance Range: 0.3~5.0Ω Base line Impedance Range: 0 – 2.5 KΩ Bandwidth 0.3 ~ 2.5 Hz Resp. Rate Measuring and Alarm Range Adult 0 ~ 120 rpm Neo/Ped 0 ~ 150 rpm Resolution 1 rpm Accuracy ±2 rpm Apean Alarm 10 ~ 40 S NIBP Method Oscillometric Mode Manual, Auto, STAT Measuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min) Measuring Period in STAT Mode 5 Min Pulse Rate Range 40 ~ 240 bpm Alarm Type SYS, DIA, MEAN Measuring and alarm range Adult Mode SYS 40 ~ 270 mmHg DIA 10 ~ 215 mmHg MEAN 20 ~ 235 mmHg Pediatric Mode SYS 40 ~ 200 mmHg DIA 10 ~ 150 mmHg MEAN 20 ~ 165 mmHg Neonatal Mode SYS 40 ~ 135 mmHg DIA 10 ~ 100 mmHg MEAN 20 ~ 110 mmHg Resolution Pressure 1mmHg Accuracy Pressure Maximum Mean error ±5mmHg Maximum Standard deviation ±8mmHg Overpressure Protection Adult Mode 297±3 mmHg Pediatric Mode 240±3 mmHg Neonatal Mode 147±3 mmHg SpO2 Measuring Range 0 ~ 100 % Alarm Range 0 ~ 100 % Resolution 1 % Accuracy 70% ~ 100% ±2 % 0% ~ 69% unspecified Actualization interval about 1 Sec. Alarm Delay 10 Sec. Pulse Rate Measuring and Alarm Range 0~254bpm Resolution 1bpm Accuracy ±2bpm TEMPERATURE Channel 1 Measuring and Alarm Range 0 ~ 50 C Resolution 0.1~C Accuracy ±0.1~C Actualization interval about 1 Sec. Average Time Constant < 10 Sec. IBP Label ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measuring and alarm range ART 0 ~ 300 mmHg PA -6 ~ 120 mmHg CVP/RAP/LAP/ICP -10 ~ 40 mmHg P1/P2 -10 ~ 300 mmHg Press Sensor Sensitivity 5 uV/V/mmHg Impedance 300-3000Ω Resolution 1 mmHg Accuracy ±2% or ±1mmHg, which great about 1 Sec.Touch Screen Patient Monitor MD9015
Touch Screen Patient Monitor MD9015
Touch Screen Patient Monitor MD9015 is a touch screen 15 inch patient monitor by Meditech 192-hour trend graph,1000 group of blood pressure list,ST segment measurements, arrhythmia analysis and more functions, Support up to 32 TCP/IP network connection,composed of a central information system.. Comes with remote control. Please see our complete range of Patient Monitor & Multiparameter Monitors Features:- 5” high resolution color TFT display with maximum 13 waveforms
- Full touch-screen enables intuitive operation by clicking on the specific parameters of the waveform in real time, standard configuration includes the navigation knob
- Pacemaker detection, electrosurgical interference proof
- Defibrillation protection and defibrillation synchronization
- SD Card slot enable memory extension for large data storage
- USB and serial port enable abundant future upgrades
- VGA output and Analog output
- OxyCRG available to judge the respiration and circulation function for neonate
- Large font display
- Arrhythmia and S-T segment analysis
- Built-in rechargeable Li-ion (6hours maximum with 2x 4200mAh batteries)
- Nurse Call function and bi-directional communication with MFM-CMS central station
- Multi language: English/Simplified Chinese/Traditional
- Chinese/Spanish/Czech/Italian/Polish/French/German/Brazilian/Portugese/Russian.
- Standard configuration: 3/5-lead ECG, NIBP, SpO2, RESP, 2-Temp, PR
- Optional: 12-lead ECG, Nellcor-SpO2, Omron NIBP, 2-IBP/4-IBP, Mainstream/Side stream CO2,
- CO, Multi-Gas, Full Touch Screen, Thermal Recorder, WLAN Accessory
- Large Data Storage: 120 hours graphic and tabular trends of all parameters; 1200 sets of NIBP
- measurement and 70 alarm events; 2-USB ports and SC card slot ensure data storage/function upgrades.
- Clinical data can be viewed and managed via Patientcare viewer software (To be released)
- Clinical network: bi-directional communication with CMS-2000 central station by wired or wireless connection,
- Complete and flexible mounting solution for ICU and operation room. High-end parameters for more flexible clinical applications.
- Invasive Blood Pressure (IBP)
- Carbon dioxide (CO2) Module
- Masimo SpO2 Module
- Thermal Printer
Touch Screen Patient Monitor MD9015
Specification: Electrocardiogram (ECG)- Input mode Five-lead ECG input / three-lead ECG input
- Lead selection I, II, III, aVR, aVL, aVF, V-
- Gain selection AUTO,0.25X,0.5X,1X,2X,4X
- Operating mode Diagnostic mode, monitoring mode, operation mode
- Calibration signal 1mV ±5%
- Protection The isolation voltage 4000V, 50/60Hz. Anti-high-frequency interference of electric knife.
- Anti-defibrillation protection.
- Pacemaker at the same time use Support
- Electrode off instructions Each electrode (RL excluded)
- Scanning speed 12.5mm/s, 25 mm/s, 50 mm/s
- Common mode rejection ratio ≥90dB
- Input impedance ≥5.0MΩ
- Measuring range Adult 30 ~ 300bpm, newborns 30 to 350 bpm
- Resolution 1 bpm
- Accuracy < ±5bpm
- Heart rate sensitivity ≥0.20mVp-p
- Alarm range 15 to 350 bpm, upper and lower limits
- Alarm indication Audible and visual alarm, display the data and parameters flashing display alarm message text prompts, there are three levels of alarm
- SPO2 Range: 1% to 99%
- Resolution: 1%
- Accuracy: 70% to 99% range: ±2%;
- 1% to 69% range: ±5%;
- Method: Dual wavelength LED
- ST-segment measurement range -2.0~+2.0mV
- ST-segment measurement accuracy Within the range of -0.8 ~ +0.8 mV: ± 0.02mV or reading± 10%, Whichever is greater; Other range: undefined
- Resolution 0.01mV
- ST-segment update cycle 10s
- ST segment alarm range -2.0 ~ +2.0 MV, the upper and lower limits continuously adjustable
- Arrhythmia types 13 kinds of (scalable)
- Respiration Rate
- Rate: 2 to 120 bpm (CO2)
- Technique: Oscillometric during inflation
- Range: Adult/Pediatric: 40 to 240 mmHg
- Neonate: 10 to 150 mmHg
- Measurement Cycle: < 40 sec. typical
- Cycles (Selectable): 2, 3, 5, 10, 15, 30 min; 1, 2, 4 hr
- STAT Mode: 5 minutes of continuous readings
- Max. Allowable Cuff
- Pressure: Adult: 300mmHg
- Pediatric: 240 mmHg;
- Neonate: 150 mmHg
- Resolution: 1 mmHg
- Transducer Accuracy: ±2 mmHg or ±2% of reading,
- Heart (Pulse) Rate
- Range: 30 to 250 bpm
- Accuracy: ±2 bpm or ±3%, whichever is greater
- Interface form External interface Range of
- measurement 0~10 kPa or (0~75) mmHg
- precision(error) (0kPa~5.4kPa) the error is ±0.3kPa、
- (5.5kPa~10.0kPa)the error is ±0.7kPa
- Alarm upper limit 2.1~13.2 kPa
- Alarm lower limit 0~6.5 kPa
- time 12s
- EtCO2 exist
- Unit kPa / mmHg / %
- Compatibility
- external main stream and side stream are compatible
FEATURED PRODUCTS
ELECTRONICS
Eames lounge chair
Classic wooden chair
Decoration wooden present
Nam gravida vulputate est venenatis eu at ullamcorper consectetur parturient suspendisse a elit lobortis ut convallis vestibulum vulputate nunc praesent mattis sem faucibus risus sociosqu.Dapibus curae a ac vestibulum a magnis ullamcorper orci a iaculis adipiscing augue a massa a torquent feugiat a. Scelerisque vestibulum.
Wine bottle lantern
iPhone dock
Augue adipiscing euismod
INNOVATIVE GADGETS
Exploring Atlanta’s modern homes
Vivamus enim sagittis aptent hac mi dui a per aptent suspendisse cras odio bibendum augue rhoncus laoreet dui praesent sodales sod...
Green interior design inspiration
A sed a risusat luctus esta anibh rhoncus hendrerit blandit nam rutrum sitmiad hac. Cras a vestibulum a varius adipiscing ut digni...
Collar brings back coffee brewing ritual
Adipiscing hac imperdiet id blandit varius scelerisque at sagittis libero dui dis volutpat vehicula mus sed ut. Lacinia dui rutrum...
Reinterprets the classic bookshelf
Aliquet parturient scele risque scele risque nibh pretium parturient suspendisse platea sapien torquent feugiat parturient hac ame...
Creative water features and exterior
Ac haca ullamcorper donec ante habi tasse donec imperdiet eturpis varius per a augue magna hac. Nec hac et vestibulum duis a tinci...